메뉴 건너뛰기




Volumn 41, Issue 1, 2008, Pages 60.e1-60.e7

P-wave and QRS complex measurements in patients undergoing hemodialysis

Author keywords

Electrocardiology; Electrophysiology; Hemodialysis; Low voltage ECG; P waves; P wave dispersion; P wave duration; Peripheral edema

Indexed keywords

BETA ADRENERGIC RECEPTOR BLOCKING AGENT; CALCIUM CHANNEL BLOCKING AGENT; DIPEPTIDYL CARBOXYPEPTIDASE INHIBITOR; ELECTROLYTE; HEMOGLOBIN;

EID: 38049016848     PISSN: 00220736     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jelectrocard.2006.03.002     Document Type: Article
Times cited : (22)

References (29)
  • 1
    • 0018376801 scopus 로고
    • Influence of hemodialysis on electrocardiographic wave forms
    • Ishikawa K., Nagasawa T., and Shimadu H. Influence of hemodialysis on electrocardiographic wave forms. Am Heart J 97 (1979) 5
    • (1979) Am Heart J , vol.97 , pp. 5
    • Ishikawa, K.1    Nagasawa, T.2    Shimadu, H.3
  • 2
    • 0019486477 scopus 로고
    • Electrocardiographic changes following dialysis
    • Diskin C.J., Salzsieder K.H., Solomon R.J., et al. Electrocardiographic changes following dialysis. Nephron 27 (1981) 94
    • (1981) Nephron , vol.27 , pp. 94
    • Diskin, C.J.1    Salzsieder, K.H.2    Solomon, R.J.3
  • 3
    • 0020696342 scopus 로고
    • Effects of dialysate sodium concentration on the appearance of ischemic EKG pattern
    • Ono K., Hisasue Y., and Kikawa K. Effects of dialysate sodium concentration on the appearance of ischemic EKG pattern. Nephron 33 (1983) 182
    • (1983) Nephron , vol.33 , pp. 182
    • Ono, K.1    Hisasue, Y.2    Kikawa, K.3
  • 4
    • 0023188754 scopus 로고
    • Relationship between changes in R wave voltage and cardiac volumes. A vectorcardiographic study during hemodialysis
    • Vitolo E., Madoi S., Palvarini M., et al. Relationship between changes in R wave voltage and cardiac volumes. A vectorcardiographic study during hemodialysis. J Electrocardiol 20 (1987) 138
    • (1987) J Electrocardiol , vol.20 , pp. 138
    • Vitolo, E.1    Madoi, S.2    Palvarini, M.3
  • 5
    • 0027234419 scopus 로고
    • Effects of hemodialysis on body surface maps in patients with chronic renal failure
    • Kinoshita O., Kimura G., Kamakura S., et al. Effects of hemodialysis on body surface maps in patients with chronic renal failure. Nephron 64 (1993) 580
    • (1993) Nephron , vol.64 , pp. 580
    • Kinoshita, O.1    Kimura, G.2    Kamakura, S.3
  • 6
    • 0027508087 scopus 로고
    • Hemodialysis changes the QRS amplitude in the electrocardiogram
    • Fuenmayor A.J., Vasquez C.J., Fuenmayor A.M., et al. Hemodialysis changes the QRS amplitude in the electrocardiogram. Int J Cardiol 41 (1993) 141
    • (1993) Int J Cardiol , vol.41 , pp. 141
    • Fuenmayor, A.J.1    Vasquez, C.J.2    Fuenmayor, A.M.3
  • 7
    • 0344417859 scopus 로고    scopus 로고
    • QRS amplitude and volume changes during hemodialysis
    • Ojanen S., Koobi T., Korhonen P., et al. QRS amplitude and volume changes during hemodialysis. Am J Nephrol 19 (1999) 423
    • (1999) Am J Nephrol , vol.19 , pp. 423
    • Ojanen, S.1    Koobi, T.2    Korhonen, P.3
  • 8
    • 0042320695 scopus 로고    scopus 로고
    • Augmentation of the amplitude of electrocardiographic QRS complexes immediately following hemodialysis: a study of 26 hemodialysis sessions of a single patient, aided by measurements of resistance/reactance/impedance
    • Madias J.E., and Narayan V. Augmentation of the amplitude of electrocardiographic QRS complexes immediately following hemodialysis: a study of 26 hemodialysis sessions of a single patient, aided by measurements of resistance/reactance/impedance. J Electrocardiol 36 (2003) 263
    • (2003) J Electrocardiol , vol.36 , pp. 263
    • Madias, J.E.1    Narayan, V.2
  • 9
    • 0014088178 scopus 로고
    • The specific resistance of biological materials-a compendium of data for the biomedical engineer and physiologist
    • Geddes L.A., and Baker L.E. The specific resistance of biological materials-a compendium of data for the biomedical engineer and physiologist. Med Biol Eng 5 (1967) 271
    • (1967) Med Biol Eng , vol.5 , pp. 271
    • Geddes, L.A.1    Baker, L.E.2
  • 10
    • 2942548865 scopus 로고    scopus 로고
    • P waves in patients with changing edematous states: implications on interpreting repeat P wave measurements in patients developing anasarca or undergoing hemodialysis
    • Madias J.E. P waves in patients with changing edematous states: implications on interpreting repeat P wave measurements in patients developing anasarca or undergoing hemodialysis. Pacing Clin Electrophysiol 27 (2004) 749
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 749
    • Madias, J.E.1
  • 11
    • 0034841457 scopus 로고    scopus 로고
    • Anasarca-mediated attenuation of the amplitude of electrocardiogram complexes: a description of a heretofore unrecognized phenomenon
    • Madias J.E., Bazaz R., Agarwal H., et al. Anasarca-mediated attenuation of the amplitude of electrocardiogram complexes: a description of a heretofore unrecognized phenomenon. J Am Coll Cardiol 38 (2001) 756
    • (2001) J Am Coll Cardiol , vol.38 , pp. 756
    • Madias, J.E.1    Bazaz, R.2    Agarwal, H.3
  • 12
    • 34547725544 scopus 로고
    • The ventricular complex in left ventricular hypertrophy as obtained by unipolar precordial and limb leads
    • Sokolow M., and Lyon T.P. The ventricular complex in left ventricular hypertrophy as obtained by unipolar precordial and limb leads. Am Heart J 37 (1949) 161
    • (1949) Am Heart J , vol.37 , pp. 161
    • Sokolow, M.1    Lyon, T.P.2
  • 13
    • 0022342536 scopus 로고
    • Electrocardiographic detection of left ventricular hypertrophy: development and prospective validation of improved criteria
    • Casale P.N., Devereux R.B., Kligfield P., et al. Electrocardiographic detection of left ventricular hypertrophy: development and prospective validation of improved criteria. J Am Coll Cardiol 6 (1985) 572
    • (1985) J Am Coll Cardiol , vol.6 , pp. 572
    • Casale, P.N.1    Devereux, R.B.2    Kligfield, P.3
  • 14
    • 5444266066 scopus 로고    scopus 로고
    • Concealment of electrocardiographically based diagnosis of left ventricular hypertrophy by anasarca
    • Madias J.E. Concealment of electrocardiographically based diagnosis of left ventricular hypertrophy by anasarca. Am J Hypertens 17 (2004) 897
    • (2004) Am J Hypertens , vol.17 , pp. 897
    • Madias, J.E.1
  • 15
    • 33645925010 scopus 로고    scopus 로고
    • Peripheral edema masks the diagnoses of P pulmonale, P mitrale, and biatrial abnormality: clinical implications for patients with heart failure
    • Madias J.E. Peripheral edema masks the diagnoses of P pulmonale, P mitrale, and biatrial abnormality: clinical implications for patients with heart failure. Congest Heart Fail 12 (2006) 20
    • (2006) Congest Heart Fail , vol.12 , pp. 20
    • Madias, J.E.1
  • 16
    • 0037097297 scopus 로고    scopus 로고
    • Significance of shortening of the mean QRS duration of the standard electrocardiogram in patients developing peripheral edema
    • Madias J.E. Significance of shortening of the mean QRS duration of the standard electrocardiogram in patients developing peripheral edema. Am J Cardiol 89 (2002) 1444
    • (2002) Am J Cardiol , vol.89 , pp. 1444
    • Madias, J.E.1
  • 17
    • 38049068598 scopus 로고    scopus 로고
    • Madias JE. Unpublished data.
  • 18
    • 12844269341 scopus 로고    scopus 로고
    • QTc interval in patients with changing edematous states: implications on interpreting repeat QTc interval measurements in patients with anasarca of varying etiology, and those undergoing hemodialysis
    • Madias J.E. QTc interval in patients with changing edematous states: implications on interpreting repeat QTc interval measurements in patients with anasarca of varying etiology, and those undergoing hemodialysis. Pacing Clin Electrophysiol 28 (2005) 54
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 54
    • Madias, J.E.1
  • 20
    • 18444415457 scopus 로고    scopus 로고
    • Increases in P-wave duration and dispersion after hemodialysis are totally (or partially) due to the procedure-induced alleviation of the body fluid overload: a hypothesis with strong experimental support
    • Madias J.E. Increases in P-wave duration and dispersion after hemodialysis are totally (or partially) due to the procedure-induced alleviation of the body fluid overload: a hypothesis with strong experimental support. Ann Noninvasive Electrocardiol 10 (2005) 129
    • (2005) Ann Noninvasive Electrocardiol , vol.10 , pp. 129
    • Madias, J.E.1
  • 21
    • 0036714015 scopus 로고    scopus 로고
    • Effects of haemodialysis on maximum P wave duration and P wave dispersion
    • Szabó Z., Kakuk G., Fülöp T., et al. Effects of haemodialysis on maximum P wave duration and P wave dispersion. Nephrol Dial Transplant 17 (2002) 1634
    • (2002) Nephrol Dial Transplant , vol.17 , pp. 1634
    • Szabó, Z.1    Kakuk, G.2    Fülöp, T.3
  • 22
    • 10744233595 scopus 로고    scopus 로고
    • Increased P wave dispersion and maximum P wave duration after hemodialysis
    • Tezcan U.K., Amasyali B., Can I., et al. Increased P wave dispersion and maximum P wave duration after hemodialysis. Ann Noninvasive Electrocardiol 9 (2004) 34
    • (2004) Ann Noninvasive Electrocardiol , vol.9 , pp. 34
    • Tezcan, U.K.1    Amasyali, B.2    Can, I.3
  • 24
    • 0031958520 scopus 로고    scopus 로고
    • Effect of hemodialysis on the dispersion of the QTc interval
    • Cupusti A., Galetta F., Morelli E., et al. Effect of hemodialysis on the dispersion of the QTc interval. Nephron 78 (1998) 425
    • (1998) Nephron , vol.78 , pp. 425
    • Cupusti, A.1    Galetta, F.2    Morelli, E.3
  • 25
    • 18144395444 scopus 로고    scopus 로고
    • Apparent amelioration of bundle branch blocks and intraventricular conduction delays mediated by anasarca
    • Madias J.E. Apparent amelioration of bundle branch blocks and intraventricular conduction delays mediated by anasarca. J Electrocardiol 38 (2005) 160
    • (2005) J Electrocardiol , vol.38 , pp. 160
    • Madias, J.E.1
  • 26
    • 33645254970 scopus 로고    scopus 로고
    • Artificial attenuation of ECG voltage produces shortening of the corresponding QRS duration: clinical implications for patients with edema
    • Madias J.E., and Macfarlane P.W. Artificial attenuation of ECG voltage produces shortening of the corresponding QRS duration: clinical implications for patients with edema. Pacing Clin Electrophysiol 28 (2005) 1060
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 1060
    • Madias, J.E.1    Macfarlane, P.W.2
  • 27
    • 0015367882 scopus 로고
    • Effect of intracardiac blood on the spatial vectorcardiogram. Results in the dog
    • Nelson C.V., Rand P.W., Angelakos E.T., and Hugenholtz P.G. Effect of intracardiac blood on the spatial vectorcardiogram. Results in the dog. Circ Res 31 (1972) 95
    • (1972) Circ Res , vol.31 , pp. 95
    • Nelson, C.V.1    Rand, P.W.2    Angelakos, E.T.3    Hugenholtz, P.G.4
  • 28
    • 0015122001 scopus 로고
    • Influence of acute variations in hematocrit on the QRS complex of the Frank electrocardiogram
    • Rosenthal A., Restieaux N.J., and Feig S.A. Influence of acute variations in hematocrit on the QRS complex of the Frank electrocardiogram. Circulation 44 (1971) 456
    • (1971) Circulation , vol.44 , pp. 456
    • Rosenthal, A.1    Restieaux, N.J.2    Feig, S.A.3
  • 29
    • 0029583210 scopus 로고
    • Bioimpedance analysis (BIA) in hemodialysis: technical aspects
    • Talluri A., and Mapia G. Bioimpedance analysis (BIA) in hemodialysis: technical aspects. Int J Artif Organs 18 (1995) 687
    • (1995) Int J Artif Organs , vol.18 , pp. 687
    • Talluri, A.1    Mapia, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.