메뉴 건너뛰기




Volumn 84, Issue 2, 2008, Pages 377-383

Amorphous and crystalline polyetheretherketone: Mechanical properties and tissue reactions during a 3-year follow-up

Author keywords

Biocompatibility; Crystallinity; Mechanical properties; Polyetheretherketone

Indexed keywords

PEEK PLATES; POLYETHERETHERKETONE; TISSUE REACTIONS;

EID: 38049013893     PISSN: 15493296     EISSN: 15524965     Source Type: Journal    
DOI: 10.1002/jbm.a.31310     Document Type: Article
Times cited : (97)

References (15)
  • 1
    • 0026560894 scopus 로고
    • Determinants of stress shielding: Design versus materials versus interface
    • Sumner DR, Galante JO. Determinants of stress shielding: Design versus materials versus interface. Clin Orthop Relat Res 1992;274:202-212.
    • (1992) Clin Orthop Relat Res , vol.274 , pp. 202-212
    • Sumner, D.R.1    Galante, J.O.2
  • 2
    • 0025389116 scopus 로고
    • Mechanical properties of biodegradable polymers and composites proposed for internal fixation of bone
    • Daniels AU, Chang MK, Andriano KP. Mechanical properties of biodegradable polymers and composites proposed for internal fixation of bone. J Appl Biomater 1990;1:57-78.
    • (1990) J Appl Biomater , vol.1 , pp. 57-78
    • Daniels, A.U.1    Chang, M.K.2    Andriano, K.P.3
  • 3
    • 0342972965 scopus 로고    scopus 로고
    • Nonresorbable polymers in bone surgery
    • Eschbach L. Nonresorbable polymers in bone surgery. Injury 2000;31 (Suppl 4):22-27.
    • (2000) Injury , vol.31 , Issue.SUPPL. 4 , pp. 22-27
    • Eschbach, L.1
  • 7
    • 12444328365 scopus 로고    scopus 로고
    • Tensile properties, tension-tension fatigue and biological response of polyetheretherketone-hydroxyapatite composites for load-bearing orthopedic implants
    • Abu Bakar MS, Cheng MH, Tang SM, Yu SC, Liao K, Tan CT, Khor KA, Cheang P. Tensile properties, tension-tension fatigue and biological response of polyetheretherketone-hydroxyapatite composites for load-bearing orthopedic implants. Biomaterials 2003;24:2245-2250.
    • (2003) Biomaterials , vol.24 , pp. 2245-2250
    • Abu Bakar, M.S.1    Cheng, M.H.2    Tang, S.M.3    Yu, S.C.4    Liao, K.5    Tan, C.T.6    Khor, K.A.7    Cheang, P.8
  • 9
    • 0141645493 scopus 로고    scopus 로고
    • Use of a novel carbon fibre composite material for the femoral stem component of a THR system: In vitro biological assessment
    • Scotchford CA, Garle MJ, Batchelor J, Bradley J, Grant DM. Use of a novel carbon fibre composite material for the femoral stem component of a THR system: in vitro biological assessment. Biomaterials 2003;24:4871-4879.
    • (2003) Biomaterials , vol.24 , pp. 4871-4879
    • Scotchford, C.A.1    Garle, M.J.2    Batchelor, J.3    Bradley, J.4    Grant, D.M.5
  • 12
    • 20544435460 scopus 로고    scopus 로고
    • Fabrication and characterization of three-dimensional poly(ether-ether-ketone)/-hydroxyapatite biocomposite scaffolds using laser sintering
    • Tan KH, Chua CK, Leong KF, Naing MW, Cheah CM. Fabrication and characterization of three-dimensional poly(ether-ether-ketone)/-hydroxyapatite biocomposite scaffolds using laser sintering. Proc Inst Mech Eng H 2005;219:183-194.
    • (2005) Proc Inst Mech Eng H , vol.219 , pp. 183-194
    • Tan, K.H.1    Chua, C.K.2    Leong, K.F.3    Naing, M.W.4    Cheah, C.M.5
  • 13
    • 0019127695 scopus 로고
    • Mechanical properties of some fibre reinforced polymer composites after implantation as fracture fixation plates
    • McKenna GB, Bradley GW, Dunn HK, Statten WO. Mechanical properties of some fibre reinforced polymer composites after implantation as fracture fixation plates. Biomaterials 1980;1:189-192.
    • (1980) Biomaterials , vol.1 , pp. 189-192
    • McKenna, G.B.1    Bradley, G.W.2    Dunn, H.K.3    Statten, W.O.4
  • 14
    • 0023510856 scopus 로고
    • Carbon fiber reinforced plastic (CFRP) plates versus stainless steel dynamic compression plates in the treatment of fractures of the tibiae in dogs
    • Skirving AP, Day R, Macdonald W, McLaren R. Carbon fiber reinforced plastic (CFRP) plates versus stainless steel dynamic compression plates in the treatment of fractures of the tibiae in dogs. Clin Orthop Relat Res 1987:117-124.
    • (1987) Clin Orthop Relat Res , pp. 117-124
    • Skirving, A.P.1    Day, R.2    Macdonald, W.3    McLaren, R.4
  • 15
    • 0034672866 scopus 로고    scopus 로고
    • Pre-clinical in vivo evaluation of orthopaedic bioabsorbable devices
    • An YH, Woolf SK, Friedman RJ. Pre-clinical in vivo evaluation of orthopaedic bioabsorbable devices. Biomaterials 2000;21:2635-2652.
    • (2000) Biomaterials , vol.21 , pp. 2635-2652
    • An, Y.H.1    Woolf, S.K.2    Friedman, R.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.