메뉴 건너뛰기




Volumn 43, Issue 1, 2005, Pages 3-11

Air and leaf temperatures and relative humidity in a naturally ventilated single-span greenhouse with a fogging system for cooling and its evaporative cooling efficiency

Author keywords

Fogging rate; Tomato; Vapor pressure deficit

Indexed keywords


EID: 37949032421     PISSN: 1880554X     EISSN: 18830986     Source Type: Journal    
DOI: 10.2525/ecb.43.3     Document Type: Article
Times cited : (13)

References (12)
  • 1
    • 0000896792 scopus 로고    scopus 로고
    • Performance of a fog system for cooling greenhouses
    • Arbel, A., Yekutieli, O., Barak, M. 1999. Performance of a fog system for cooling greenhouses. J. Agric. Eng. Res. 72: 129-136.
    • (1999) J. Agric. Eng. Res. , vol.72 , pp. 129-136
    • Arbel, A.1    Yekutieli, O.2    Barak, M.3
  • 2
    • 0037239324 scopus 로고    scopus 로고
    • Combination of forced ventilation and fogging systems for cooling greenhouses
    • DOI 10.1016/S1537-5110(02)00216-7
    • Arbel, A., Barak, M., Shklyar, A. 2003. Combination of forced ventilation and fogging system for cooling greenhouse. Biosystem Eng. 84: 45-55. (Pubitemid 36128235)
    • (2003) Biosystems Engineering , vol.84 , Issue.1 , pp. 45-55
    • Arbel, A.1    Barak, M.2    Shklyar, A.3
  • 3
    • 0002099109 scopus 로고
    • The environment in evaporatively cooled greenhouses
    • Bailey, B. J. 1990. The environment in evaporatively cooled greenhouses. Acta Hortic. 287: 59-66.
    • (1990) Acta Hortic , vol.287 , pp. 59-66
    • Bailey, B.J.1
  • 4
    • 0024619778 scopus 로고
    • Evaporative cooling using a pneumatic misting system
    • Bottcher, R. W., Baughman, G. R., Kesler, D. J. 1989. Evaporative cooling using a pneumatic misting system. Trans. ASAE 32: 671-676.
    • (1989) Trans. ASAE , vol.32 , pp. 671-676
    • Bottcher, R.W.1    Baughman, G.R.2    Kesler, D.J.3
  • 6
    • 35648951989 scopus 로고
    • Try alternative methods of evaporative cooling
    • Giacomelii, G. A., Roberts, W. 1989. Try alternative methods of evaporative cooling. Acta Hortic. 257: 29-30.
    • (1989) Acta Hortic , vol.257 , pp. 29-30
    • Giacomelii, G.A.1    Roberts, W.2
  • 7
    • 33144488879 scopus 로고    scopus 로고
    • Temperature and humidity environments inside a naturally ventilated greenhouse with the evaporative fog cooling system
    • Japanese text with English summary
    • Hayashi, M., Sugahara, T., Nakajima, H, 1998. Temperature and humidity environments inside a naturally ventilated greenhouse with the evaporative fog cooling system. (Japanese text with English summary) Environ. Control Biol. 36: 97-104.
    • (1998) Environ. Control Biol. , vol.36 , pp. 97-104
    • Hayashi, M.1    Sugahara, T.2    Nakajima, H.3
  • 8
    • 0035798909 scopus 로고    scopus 로고
    • Effect of misting on transpiration and conductances of greenhouse rose canopy
    • Katsoulas, N., Bailie, A., Kittas, C. 2001. Effect of misting on transpiration and conductances of greenhouse rose canopy. Agr. For. Meteorol. 106: 233-247.
    • (2001) Agr. For. Meteorol. , vol.106 , pp. 233-247
    • Katsoulas, N.1    Bailie, A.2    Kittas, C.3
  • 10
    • 0000579129 scopus 로고
    • Cooling of greenhouse with compressed air fogging nozzles
    • Montero, J. I., Anton, A., Biel, C., Franquet, A. 1990. Cooling of greenhouse with compressed air fogging nozzles. Acta Hortic. 281: 199-209.
    • (1990) Acta Hortic , vol.281 , pp. 199-209
    • Montero, J.I.1    Anton, A.2    Biel, C.3    Franquet, A.4
  • 12
    • 0007940787 scopus 로고
    • Experimental evaluation of poultry mist-fog systems
    • Timmons, M. B., Baughman, G. R. 1983. Experimental evaluation of poultry mist-fog systems. Trans. ASAE 26: 207-210.
    • (1983) Trans. ASAE , vol.26 , pp. 207-210
    • Timmons, M.B.1    Baughman, G.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.