메뉴 건너뛰기




Volumn 27, Issue 1, 2008, Pages 224-228

Measurement of longitudinal (T1) relaxation in the human lung at 3.0 Tesla with tissue-based and regional gradient analyses

Author keywords

3.0T; Gravity; Lung; Magnetic resonance imaging; Radial; T1 relaxation

Indexed keywords

ADULT; ARTICLE; FEMALE; GRAVITY; HUMAN; HUMAN EXPERIMENT; HUMAN TISSUE; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; LUNG BLOOD VESSEL; LUNG PARENCHYMA; LUNG SLICE; MALE; MEASUREMENT; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 37849048959     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21243     Document Type: Article
Times cited : (15)

References (19)
  • 1
    • 0032928766 scopus 로고    scopus 로고
    • MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR
    • Mai VM, Berr SS. MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR. J Magn Reson Imaging 1999;9:483-487.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 483-487
    • Mai, V.M.1    Berr, S.S.2
  • 2
    • 0343183915 scopus 로고    scopus 로고
    • Optimization and evaluation of he signal intensity change in multisection oxygen-enhanced MR lung imaging
    • Loffler R, Muller CJ, Peller M, et al. Optimization and evaluation of he signal intensity change in multisection oxygen-enhanced MR lung imaging. Magn Reson Med 2000;43:860-866.
    • (2000) Magn Reson Med , vol.43 , pp. 860-866
    • Loffler, R.1    Muller, C.J.2    Peller, M.3
  • 4
    • 20044367844 scopus 로고    scopus 로고
    • T1 mapping of the entire lung parenchyma: Influence of the respiratory phase in healthy individuals
    • Stadler A, Jakob PM, Griswold M, et al. T1 mapping of the entire lung parenchyma: influence of the respiratory phase in healthy individuals. J Magn Reson Imaging 2005;21:759-764.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 759-764
    • Stadler, A.1    Jakob, P.M.2    Griswold, M.3
  • 5
    • 0033406838 scopus 로고    scopus 로고
    • Distribution of pulmonary blood flow
    • West JB. Distribution of pulmonary blood flow. Am J Respir Crit Care Med 1999;160:1802-1803.
    • (1999) Am J Respir Crit Care Med , vol.160 , pp. 1802-1803
    • West, J.B.1
  • 6
    • 0026094793 scopus 로고
    • Gravity is a minor determinant of pulmonary blood flow distribution
    • Glenny RW, Lamm WJ, Albert RK, Robertson HT. Gravity is a minor determinant of pulmonary blood flow distribution. J Appl Physiol 1991;71:620-629.
    • (1991) J Appl Physiol , vol.71 , pp. 620-629
    • Glenny, R.W.1    Lamm, W.J.2    Albert, R.K.3    Robertson, H.T.4
  • 7
    • 31944442383 scopus 로고    scopus 로고
    • Gravity-dependent signal gradients on MR images of the lung in supine and prone positions: A comparison with isogravitational signal variability
    • Bankier AA, Storey P, Mai VM, Edelman RR, Chen Q. Gravity-dependent signal gradients on MR images of the lung in supine and prone positions: a comparison with isogravitational signal variability. J Magn Reson Imaging 2006;23:115-122.
    • (2006) J Magn Reson Imaging , vol.23 , pp. 115-122
    • Bankier, A.A.1    Storey, P.2    Mai, V.M.3    Edelman, R.R.4    Chen, Q.5
  • 8
    • 16544381854 scopus 로고    scopus 로고
    • Imaging lung function using rapid dynamic acquisition of T1-maps during oxygen enhancement
    • Arnold JF, Fidler F, Wang T, Pracht ED, Schmidt M, Jakob PM. Imaging lung function using rapid dynamic acquisition of T1-maps during oxygen enhancement. MAGMA. 2004;16:246-253.
    • (2004) MAGMA , vol.16 , pp. 246-253
    • Arnold, J.F.1    Fidler, F.2    Wang, T.3    Pracht, E.D.4    Schmidt, M.5    Jakob, P.M.6
  • 11
    • 0001480742 scopus 로고
    • Quantification of T1 values by SNAPSHOT-FLASH NMR imaging
    • Deichman R, Haase A. Quantification of T1 values by SNAPSHOT-FLASH NMR imaging. J Magn Reson Imaging 1992;96:608-612.
    • (1992) J Magn Reson Imaging , vol.96 , pp. 608-612
    • Deichman, R.1    Haase, A.2
  • 12
    • 0014732355 scopus 로고
    • Time saving in measurement of NMR and EPR relaxation times
    • Look DC, Locker DR. Time saving in measurement of NMR and EPR relaxation times. Rev Sci Instrum 1970;41:250-251.
    • (1970) Rev Sci Instrum , vol.41 , pp. 250-251
    • Look, D.C.1    Locker, D.R.2
  • 13
    • 1342330052 scopus 로고    scopus 로고
    • MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results
    • de Bazelaire CM, Duhamel GD, Rofsky NM, Alsop DC. MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results. Radiology 2004;230:652-659.
    • (2004) Radiology , vol.230 , pp. 652-659
    • de Bazelaire, C.M.1    Duhamel, G.D.2    Rofsky, N.M.3    Alsop, D.C.4
  • 16
    • 24144448806 scopus 로고    scopus 로고
    • T1, T2 relaxation and magnetization transfer in tissue at 3T
    • Stanisz GJ, Odrobina EE, Pun J, et al. T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med 2005;54:507-512.
    • (2005) Magn Reson Med , vol.54 , pp. 507-512
    • Stanisz, G.J.1    Odrobina, E.E.2    Pun, J.3
  • 17
    • 0023601826 scopus 로고
    • Regional lung density and blood volume in nonsmoking and smoking subjects measured by PET
    • Brudin LH, Rhodes CG, Valind SO, et al. Regional lung density and blood volume in nonsmoking and smoking subjects measured by PET. J Appl Physiol 1987;63:1324-1334.
    • (1987) J Appl Physiol , vol.63 , pp. 1324-1334
    • Brudin, L.H.1    Rhodes, C.G.2    Valind, S.O.3
  • 18
    • 0023233179 scopus 로고
    • Gravity-independent inequality in pulmonary blood flow in humans
    • Hakim TS, Lisbona R, Dean GW. Gravity-independent inequality in pulmonary blood flow in humans. J Appl Physiol 1987;63:1114-1121.
    • (1987) J Appl Physiol , vol.63 , pp. 1114-1121
    • Hakim, T.S.1    Lisbona, R.2    Dean, G.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.