메뉴 건너뛰기




Volumn 31, Issue 1, 2008, Pages 121-

The art of making reliable defibrillator leads

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL HEART PACEMAKER; DEFIBRILLATION; DEFIBRILLATOR; DEVICE; HUMAN; IMPLANT; RELIABILITY; SHORT SURVEY;

EID: 37549055840     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2007.00935.x     Document Type: Short Survey
Times cited : (1)

References (5)
  • 1
    • 34247186286 scopus 로고    scopus 로고
    • Increased incidence of subacute lead perforation noted with one implantable cardioverter-defibrillator
    • Danik SB, Mansour M, Singh J, Reddy V, Ellinor P, Milan D, Heist E, et al. Increased incidence of subacute lead perforation noted with one implantable cardioverter-defibrillator. Heart Rhythm 2007 4 : 439 442.
    • (2007) Heart Rhythm , vol.4 , pp. 439-442
    • Danik, S.B.1    Mansour, M.2    Singh, J.3    Reddy, V.4    Ellinor, P.5    Milan, D.6    Heist, E.7
  • 2
    • 34248579318 scopus 로고    scopus 로고
    • Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years
    • Kleemann T, Becker T, Doenges K, Vater M, Senges J, Schneider S, Saggau W, et al. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years. Circulation 2007 115 : 2474 2480.
    • (2007) Circulation , vol.115 , pp. 2474-2480
    • Kleemann, T.1    Becker, T.2    Doenges, K.3    Vater, M.4    Senges, J.5    Schneider, S.6    Saggau, W.7
  • 3
    • 15844398311 scopus 로고    scopus 로고
    • Long term complications in single and dual chamber pacing are influenced by surgical experience and patient morbidity
    • Eberhardt F, Bode F, Bonnemeier H, Boguschewski F, Schlei, M, Peters W, Wiegand, U. Long term complications in single and dual chamber pacing are influenced by surgical experience and patient morbidity. Heart 2005 91 : 500 506.
    • (2005) Heart , vol.91 , pp. 500-506
    • Eberhardt, F.1    Bode, F.2    Bonnemeier, H.3    Boguschewski, F.4    Schlei, M.5    Peters, W.6    Wiegand, U.7
  • 4
    • 0034756479 scopus 로고    scopus 로고
    • Pacemaker lead complications: When is extraction appropriate and what can we learn from published data?
    • Bracke FA, Meijer A, van Gelder LM. Pacemaker lead complications: When is extraction appropriate and what can we learn from published data? Heart 2001 85 : 254 259.
    • (2001) Heart , vol.85 , pp. 254-259
    • Bracke, F.A.1    Meijer, A.2    Van Gelder, L.M.3
  • 5
    • 0042701466 scopus 로고    scopus 로고
    • A randomized prospective study of single coil versus dual coil defibrillation in patients with ventricular arrhythmias undergoing implantable cardioverter defibrillator therapy
    • Rinaldi CA, Simon RD, Geelen P, Reek S, Baszko A, Kuehl M, Gill J. A randomized prospective study of single coil versus dual coil defibrillation in patients with ventricular arrhythmias undergoing implantable cardioverter defibrillator therapy. Pacing Clin Electrophysiol 2003 26 : 1684 1690.
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 1684-1690
    • Rinaldi, C.A.1    Simon, R.D.2    Geelen, P.3    Reek, S.4    Baszko, A.5    Kuehl, M.6    Gill, J.7