메뉴 건너뛰기




Volumn 106, Issue 1, 2008, Pages 171-174

Noninvasive cardiac output determination using applanation tonometry-derived radial artery pulse contour analysis in critically ill patients

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ANALYTICAL ERROR; ARTERY CATHETER; ARTICLE; CARDIOPULMONARY HEMODYNAMICS; CLINICAL ARTICLE; CONTROLLED STUDY; CRITICAL ILLNESS; CRITICALLY ILL PATIENT; DATA ANALYSIS; FEMALE; HEART OUTPUT MEASUREMENT; HUMAN; INTENSIVE CARE UNIT; INTERMETHOD COMPARISON; MALE; NON INVASIVE MEASUREMENT; PATIENT MONITORING; PRESSOR RESPONSE; PRIORITY JOURNAL; PULMONARY ARTERY; PULSE PRESSURE; RADIAL ARTERY; SIGNAL DETECTION; STATISTICAL ANALYSIS; THERMODILUTION; TONOMETRY; WAVEFORM;

EID: 37549044272     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/01.ane.0000297440.52059.2c     Document Type: Article
Times cited : (20)

References (13)
  • 2
    • 34548366219 scopus 로고    scopus 로고
    • Evidence-based review of the use of the pulmonary artery catheter: Impact data and complications
    • Hadian M, Pinsky MR. Evidence-based review of the use of the pulmonary artery catheter: impact data and complications. Crit Care 2006;10(suppl 3):S8
    • (2006) Crit Care , vol.10 , Issue.SUPPL. 3
    • Hadian, M.1    Pinsky, M.R.2
  • 3
    • 0032734448 scopus 로고    scopus 로고
    • Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution
    • Goedje O, Hoeke K, Lichtwarck-Aschoff M, Faltchauser A, Lamm P, Reichart B. Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution. Crit Care Med 1999;27:2407-12
    • (1999) Crit Care Med , vol.27 , pp. 2407-2412
    • Goedje, O.1    Hoeke, K.2    Lichtwarck-Aschoff, M.3    Faltchauser, A.4    Lamm, P.5    Reichart, B.6
  • 6
    • 0033048761 scopus 로고    scopus 로고
    • Age-related abnormalities in arterial compliance identified by pressure pulse contour analysis: Aging and arterial compliance
    • McVeigh GE, Bratteli CW, Morgan DJ, Alinder CM, Glasser SP, Finkelstein SM, Cohn JN. Age-related abnormalities in arterial compliance identified by pressure pulse contour analysis: aging and arterial compliance. Hypertension 1999;33:1392-8
    • (1999) Hypertension , vol.33 , pp. 1392-1398
    • McVeigh, G.E.1    Bratteli, C.W.2    Morgan, D.J.3    Alinder, C.M.4    Glasser, S.P.5    Finkelstein, S.M.6    Cohn, J.N.7
  • 7
    • 33745404705 scopus 로고    scopus 로고
    • Impaired renal allograft function is associated with increased arterial stiffness in renal transplant recipients
    • Kneifel M, Scholze A, Burkert A, Offermann G, Rothermund L, Zidek W, Tepel M. Impaired renal allograft function is associated with increased arterial stiffness in renal transplant recipients. Am J Transplant 2006;6:1624-30
    • (2006) Am J Transplant , vol.6 , pp. 1624-1630
    • Kneifel, M.1    Scholze, A.2    Burkert, A.3    Offermann, G.4    Rothermund, L.5    Zidek, W.6    Tepel, M.7
  • 8
    • 17144455895 scopus 로고    scopus 로고
    • A comparison between systolic and diastolic pulse contour analysis in the evaluation of arterial stiffness
    • Rietzschel ER, Boeykens E, De Buyzere ML, Duprez DA, Clement DL. A comparison between systolic and diastolic pulse contour analysis in the evaluation of arterial stiffness. Hypertension 2001;37:e15-e22
    • (2001) Hypertension , vol.37
    • Rietzschel, E.R.1    Boeykens, E.2    De Buyzere, M.L.3    Duprez, D.A.4    Clement, D.L.5
  • 9
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output meaurement techniques
    • Critchley LAH, Critchley JAJH. A meta-analysis of studies using bias and precision statistics to compare cardiac output meaurement techniques. J Clin Monit Comput 1999;15:85-91
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2
  • 11
    • 0032967199 scopus 로고    scopus 로고
    • Non-invasive cardiac output determination: State of the art
    • Kööbi T. Non-invasive cardiac output determination: state of the art. Curr Opin Anaesthesiol 1999;12:9-13
    • (1999) Curr Opin Anaesthesiol , vol.12 , pp. 9-13
    • Kööbi, T.1
  • 13
    • 0030733450 scopus 로고    scopus 로고
    • Noninvasive assessment of cardiac output in critically ill patients by analysis of the finger blood pressure waveform
    • Hirschl MM, Binder M, Gwechenberger M, Herkner H, Bur A, Kittler H, Laggner AN. Noninvasive assessment of cardiac output in critically ill patients by analysis of the finger blood pressure waveform. Crit Care Med 1997;25:1909-14
    • (1997) Crit Care Med , vol.25 , pp. 1909-1914
    • Hirschl, M.M.1    Binder, M.2    Gwechenberger, M.3    Herkner, H.4    Bur, A.5    Kittler, H.6    Laggner, A.N.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.