-
2
-
-
0014175990
-
Therapeutic temperature distribution produced by ultrasound as modified by dosage and volume of tissue exposed
-
Lehmann JF, DeLateur BJ, Stonebridge JS, Warren CG. Therapeutic temperature distribution produced by ultrasound as modified by dosage and volume of tissue exposed. Arch Phys Med Rehabil. 1967; 48:662-666.
-
(1967)
Arch Phys Med Rehabil
, vol.48
, pp. 662-666
-
-
Lehmann, J.F.1
DeLateur, B.J.2
Stonebridge, J.S.3
Warren, C.G.4
-
3
-
-
0034931395
-
A review of therapeutic ultrasound: Effectiveness studies
-
Robertson VJ, Baker KG. A review of therapeutic ultrasound: effectiveness studies. Phys Ther. 2001;81:1339-1350.
-
(2001)
Phys Ther
, vol.81
, pp. 1339-1350
-
-
Robertson, V.J.1
Baker, K.G.2
-
4
-
-
0031973509
-
Effects of two ultrasound devices and angles of application on temperature of the tissue phantom
-
Kimura I, Gulick DT, Shelly J, Ziskin MC. Effects of two ultrasound devices and angles of application on temperature of the tissue phantom. J Orthop Sports Phys Ther. 1998;27:27-31.
-
(1998)
J Orthop Sports Phys Ther
, vol.27
, pp. 27-31
-
-
Kimura, I.1
Gulick, D.T.2
Shelly, J.3
Ziskin, M.C.4
-
5
-
-
0029080155
-
Rate of temperature increase in human muscle during 1 MHz and 3 MHz continuous ultrasound
-
Draper DO, Castel JC, Castel D. Rate of temperature increase in human muscle during 1 MHz and 3 MHz continuous ultrasound. J Orthop Sports Phys Ther. 1995;22:142-150.
-
(1995)
J Orthop Sports Phys Ther
, vol.22
, pp. 142-150
-
-
Draper, D.O.1
Castel, J.C.2
Castel, D.3
-
6
-
-
0028842289
-
Temperature changes in deep muscles of humans during ice and ultrasound therapies: An in vivo study
-
Draper DO, Schulthies SS, Sorvisto P, Hautala AM. Temperature changes in deep muscles of humans during ice and ultrasound therapies: an in vivo study. J Orthop Sports Phys Ther. 1995;21:153-157.
-
(1995)
J Orthop Sports Phys Ther
, vol.21
, pp. 153-157
-
-
Draper, D.O.1
Schulthies, S.S.2
Sorvisto, P.3
Hautala, A.M.4
-
7
-
-
0000027439
-
The stretching window part two: Rate of thermal decay in deep muscle following 1-MHz ultrasound
-
Rose S, Draper DO, Schulthies SS, Durrant E. The stretching window part two: rate of thermal decay in deep muscle following 1-MHz ultrasound. J Athl Train. 1996;31: 139-143.
-
(1996)
J Athl Train
, vol.31
, pp. 139-143
-
-
Rose, S.1
Draper, D.O.2
Schulthies, S.S.3
Durrant, E.4
-
8
-
-
0002452271
-
Temperature rise in human muscle during ultrasound treatments using Flex-All as a coupling agent
-
Ashton DF, Draper DO, Myrer JW. Temperature rise in human muscle during ultrasound treatments using Flex-All as a coupling agent. J Athl Train. 1998;33: 136-140.
-
(1998)
J Athl Train
, vol.33
, pp. 136-140
-
-
Ashton, D.F.1
Draper, D.O.2
Myrer, J.W.3
-
9
-
-
0000846459
-
Immediate and residual changes in dorsiflexion range of motion using an ultrasound heat and stretch routine
-
Draper DO, Anderson C, Schulthies SS, Ricard MD. Immediate and residual changes in dorsiflexion range of motion using an ultrasound heat and stretch routine. J Athl Train. 1998;33:141-144.
-
(1998)
J Athl Train
, vol.33
, pp. 141-144
-
-
Draper, D.O.1
Anderson, C.2
Schulthies, S.S.3
Ricard, M.D.4
-
10
-
-
0003036034
-
Heat distribution in the lower leg from pulsed short-wave diathermy and ultrasound treatments
-
Garrett CL, Draper DO, Knight KL. Heat distribution in the lower leg from pulsed short-wave diathermy and ultrasound treatments. J Athl Train. 2000;35:50-55.
-
(2000)
J Athl Train
, vol.35
, pp. 50-55
-
-
Garrett, C.L.1
Draper, D.O.2
Knight, K.L.3
-
11
-
-
0037240594
-
A comparison of temperature increases produced by 2 commonly used ultrasound units
-
Holcomb WR, Joyce CJ. A comparison of temperature increases produced by 2 commonly used ultrasound units. J Athl Train. 2003;38:24-27.
-
(2003)
J Athl Train
, vol.38
, pp. 24-27
-
-
Holcomb, W.R.1
Joyce, C.J.2
-
12
-
-
0141482200
-
Identical 3-MHz ultrasound treatments with different devices produce different intramuscular temperatures
-
Merrick MA, Bernard KD, Devor ST, Williams MJ. Identical 3-MHz ultrasound treatments with different devices produce different intramuscular temperatures. J Orthop Sports Phys Ther. 2003;33: 379-385.
-
(2003)
J Orthop Sports Phys Ther
, vol.33
, pp. 379-385
-
-
Merrick, M.A.1
Bernard, K.D.2
Devor, S.T.3
Williams, M.J.4
-
13
-
-
4844223511
-
Three-MHz ultrasound heats deeper into the tissues than originally theorized
-
Hayes BT, Merrick MA, Sandrey MA, Cordova ML. Three-MHz ultrasound heats deeper into the tissues than originally theorized. J Athl Train. 2004;39:230-234.
-
(2004)
J Athl Train
, vol.39
, pp. 230-234
-
-
Hayes, B.T.1
Merrick, M.A.2
Sandrey, M.A.3
Cordova, M.L.4
-
14
-
-
9644254605
-
A comparison of intramuscular temperatures during 10-minute 1.0 MHz ultrasound treatments at different intensities
-
Leonard J, Merrick MA, Ingersoll CD, Cordova ML. A comparison of intramuscular temperatures during 10-minute 1.0 MHz ultrasound treatments at different intensities. J Sport Rehabil. 2004;13:244-254.
-
(2004)
J Sport Rehabil
, vol.13
, pp. 244-254
-
-
Leonard, J.1
Merrick, M.A.2
Ingersoll, C.D.3
Cordova, M.L.4
-
15
-
-
16444384958
-
Effects of altering intensity during a 10 minute 1MHz ultrasound treatment on triceps surae temperature elevation
-
Burr PO, Demchak TJ, Cordova ML, et al. Effects of altering intensity during a 10 minute 1MHz ultrasound treatment on triceps surae temperature elevation. J Sport Rehabil. 2004;13:275-286.
-
(2004)
J Sport Rehabil
, vol.13
, pp. 275-286
-
-
Burr, P.O.1
Demchak, T.J.2
Cordova, M.L.3
-
16
-
-
0001612063
-
Temperature changes in human patellar tendon in response to therapeutic ultrasound
-
Chan AK, Myrer JW, Measom GJ, Draper DO. Temperature changes in human patellar tendon in response to therapeutic ultrasound. J Athl Train. 1998;33:130-135.
-
(1998)
J Athl Train
, vol.33
, pp. 130-135
-
-
Chan, A.K.1
Myrer, J.W.2
Measom, G.J.3
Draper, D.O.4
-
17
-
-
0019949355
-
The importance of measurement of effective transducers radiating area in the testing and calibration of "therapeutic" ultrasonic instruments
-
Fyfe MC, Parnell SM. The importance of measurement of effective transducers radiating area in the testing and calibration of "therapeutic" ultrasonic instruments. Health Phys. 1982;43:377-381.
-
(1982)
Health Phys
, vol.43
, pp. 377-381
-
-
Fyfe, M.C.1
Parnell, S.M.2
-
18
-
-
33845908717
-
Analysis of effective radiating area, power, intensity, and field characteristics of ultrasound transducers
-
Johns LD, Straub SJ, Howard SM. Analysis of effective radiating area, power, intensity, and field characteristics of ultrasound transducers. Arch Phys Med Rehabil. 2007;88:124-129.
-
(2007)
Arch Phys Med Rehabil
, vol.88
, pp. 124-129
-
-
Johns, L.D.1
Straub, S.J.2
Howard, S.M.3
-
19
-
-
37549040356
-
-
US Food and Drug Administration. Performance standards for sonic, infrasonic, and ultrasonic radiation emitting products. 21 Federal Register 1050 (1999).
-
US Food and Drug Administration. Performance standards for sonic, infrasonic, and ultrasonic radiation emitting products. 21 Federal Register 1050 (1999).
-
-
-
-
20
-
-
34250013344
-
Variability in effective radiating area and output power in new ultrasound transducers at 3 MHz
-
Johns LD, Straub SJ, Howard SH. Variability in effective radiating area and output power in new ultrasound transducers at 3 MHz. J Athl Train. 2007;42:22-28.
-
(2007)
J Athl Train
, vol.42
, pp. 22-28
-
-
Johns, L.D.1
Straub, S.J.2
Howard, S.H.3
-
21
-
-
37549018281
-
-
Standards Association of Australia, Parkville, Victoria, Australia: Standards Association of Australia;
-
Standards Association of Australia. AS T40-1969: Ultrasonic Therapeutic Equipment. Parkville, Victoria, Australia: Standards Association of Australia; 1969.
-
(1969)
AS T40-1969: Ultrasonic Therapeutic Equipment
-
-
-
22
-
-
0042614371
-
-
Geneva, Switzerland: Bureau Central de la Commission Eletrotechnique Internationale;, Geneva. International Electrotechnical Commission Publication 150
-
Testing and Calibration of Ultrasonic Therapeutic Equipment. Geneva, Switzerland: Bureau Central de la Commission Eletrotechnique Internationale; 1963. Geneva. International Electrotechnical Commission Publication 150.
-
(1963)
Testing and Calibration of Ultrasonic Therapeutic Equipment
-
-
-
23
-
-
37549044428
-
-
International Electrotechnical Committee. Ultrasonics - Physiotherapy Systems - Performance Requirements and Methods of Measurement in the Frequency Range 0.5 to 5 MHz. Geneva, Switzerland: International Electrotechnical Committee; 1996: Annex C. (IEC 61689)
-
International Electrotechnical Committee. Ultrasonics - Physiotherapy Systems - Performance Requirements and Methods of Measurement in the Frequency Range 0.5 to 5 MHz. Geneva, Switzerland: International Electrotechnical Committee; 1996: Annex C. (IEC 61689)
-
-
-
-
24
-
-
0028339558
-
The performance of ultrasound physiotherapy machines in Lothian Region, Scotland
-
Pye SD, Milford C. The performance of ultrasound physiotherapy machines in Lothian Region, Scotland. Ultrasound Med Biol. 1994;20:347-359.
-
(1994)
Ultrasound Med Biol
, vol.20
, pp. 347-359
-
-
Pye, S.D.1
Milford, C.2
-
25
-
-
0036596330
-
Measurement accuracy [letter to the editor]
-
Roveti D. Measurement accuracy [letter to the editor]. Phys Ther. 2002;82:616.
-
(2002)
Phys Ther
, vol.82
, pp. 616
-
-
Roveti, D.1
-
26
-
-
0036183845
-
A calibration study of therapeutic ultrasound units
-
Artho PA, Thyne JG, Warring BP, et al. A calibration study of therapeutic ultrasound units. Phys Ther. 2002;82:257-263.
-
(2002)
Phys Ther
, vol.82
, pp. 257-263
-
-
Artho, P.A.1
Thyne, J.G.2
Warring, B.P.3
-
27
-
-
0028212543
-
Development of standard measurement methods for essential properties of ultrasound therapy equipment
-
Hekkenberg RT, Reibold R, Zeqiri B. Development of standard measurement methods for essential properties of ultrasound therapy equipment. Ultrasound Med Biol. 1994;20:83-98.
-
(1994)
Ultrasound Med Biol
, vol.20
, pp. 83-98
-
-
Hekkenberg, R.T.1
Reibold, R.2
Zeqiri, B.3
-
28
-
-
35848952516
-
Ultrasound heating is curvilinear in nature and varies between transducers from the same manufacturer
-
Demchak TJ, Straub SJ, Johns LD. Ultrasound heating is curvilinear in nature and varies between transducers from the same manufacturer, J Sport Rehabil. 2007;16: 122-130.
-
(2007)
J Sport Rehabil
, vol.16
, pp. 122-130
-
-
Demchak, T.J.1
Straub, S.J.2
Johns, L.D.3
-
29
-
-
0032998483
-
Ultrasound therapy for musculoskeletal disorders: A systematic review
-
van der Windt DA, van der Heijden GJ, van den Berg SG, et al. Ultrasound therapy for musculoskeletal disorders: a systematic review. Pain. 1999;81:257-271.
-
(1999)
Pain
, vol.81
, pp. 257-271
-
-
van der Windt, D.A.1
van der Heijden, G.J.2
van den Berg, S.G.3
-
31
-
-
0004090213
-
-
3rd ed. Philadelphia, Pa: FA Davis Co;
-
Starkey C. Therapeutic Modalities. 3rd ed. Philadelphia, Pa: FA Davis Co; 2004:174.
-
(2004)
Therapeutic Modalities
, pp. 174
-
-
Starkey, C.1
|