메뉴 건너뛰기




Volumn 5, Issue 2, 1996, Pages 241-246

Failure analysis of an ammonia refrigerant condenser tube

Author keywords

Failure analysis; Steel type API 5L gr. B; Weld failure; Welding

Indexed keywords


EID: 3743054924     PISSN: 10599495     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02650894     Document Type: Article
Times cited : (5)

References (14)
  • 3
    • 0005783735 scopus 로고
    • Standard Methods for Notched Bar Impact Testing of Metallic Materials
    • E 23, ASTM
    • "Standard Methods for Notched Bar Impact Testing of Metallic Materials," E 23, Annual Book of ASTM Standards, Part 10, ASTM, 1980, p 197-212
    • (1980) Annual Book of ASTM Standards , Issue.10 PART , pp. 197-212
  • 4
    • 0343977073 scopus 로고
    • ANSI/AWS B 4.0-85, American Welding Society, Florida
    • Standard Methods for Mechanical Testing of Welds, ANSI/AWS B 4.0-85, American Welding Society, Florida, 1985, p 31-37
    • (1985) Standard Methods for Mechanical Testing of Welds , pp. 31-37
  • 11
    • 0043034893 scopus 로고
    • Charpy Requirements for Sub-size Specimens
    • O.L. Towers, Charpy Requirements for Sub-size Specimens, Weld. Inst. Res. Bull., Vol 19 (No. 8), 1978, p 224-227
    • (1978) Weld. Inst. Res. Bull. , vol.19 , Issue.8 , pp. 224-227
    • Towers, O.L.1
  • 12
    • 0022689455 scopus 로고
    • Testing Sub-size Charpy Specimens: Part I - The Influence of Thickness on the Ductile/Brittle Transition
    • O.L. Towers, Testing Sub-size Charpy Specimens: Part I - The Influence of Thickness on the Ductile/Brittle Transition, Met. Constr., Vol 18 (No. 3), 1986, p 171R-176R
    • (1986) Met. Constr. , vol.18 , Issue.3
    • Towers, O.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.