메뉴 건너뛰기




Volumn 66, Issue 4, 2007, Pages 339-345

A novel formula for the classification of blood vessels according to symmetry, asymmetry and hypoplasia

Author keywords

Asymmetry; Blood vessels; Hypoplasia; Symmetry

Indexed keywords

ADOLESCENT; ADULT; ALGORITHM; ARTERY DIAMETER; ARTERY DYSPLASIA; ARTICLE; BASILAR ARTERY; BRAIN CIRCULUS ARTERIOSUS; CALCULATION; CAMERA; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTER PROGRAM; CONTROLLED STUDY; DIGITAL IMAGING; DISEASE CLASSIFICATION; FEMALE; HUMAN; IMAGE RECONSTRUCTION; MAJOR CLINICAL STUDY; MALE; MORPHOLOGY; POLAND; POSTERIOR CEREBRAL ARTERY; QUALITATIVE ANALYSIS; RENAL ARTERY; SCHOOL CHILD; STANDARDIZATION; UNIVERSITY HOSPITAL; VERTEBRAL ARTERY;

EID: 37349116265     PISSN: 00155659     EISSN: 16443284     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (17)

References (31)
  • 2
    • 0001688899 scopus 로고
    • Circle of Willis in cerebral vascular disorders. The anatomical structure
    • Alpers BJ, Berry RG (1963) Circle of Willis in cerebral vascular disorders. The anatomical structure. Arch Neurol, 8: 398-402.
    • (1963) Arch Neurol , vol.8 , pp. 398-402
    • Alpers, B.J.1    Berry, R.G.2
  • 3
    • 0142242251 scopus 로고    scopus 로고
    • Comparative histological and biometric study of the coronary, radial and left internal thoracic arteries
    • Barry MM, Foulon P, Touati G, Ledoux B, Sevestre H, Carmi D, Laude M (2003) Comparative histological and biometric study of the coronary, radial and left internal thoracic arteries. Surg Radiol Anat, 25: 284-289.
    • (2003) Surg Radiol Anat , vol.25 , pp. 284-289
    • Barry, M.M.1    Foulon, P.2    Touati, G.3    Ledoux, B.4    Sevestre, H.5    Carmi, D.6    Laude, M.7
  • 4
    • 0037366666 scopus 로고    scopus 로고
    • Multiple detector-row CT angiography of the renal and mesenteric vessels
    • Fleischmann D (2003) Multiple detector-row CT angiography of the renal and mesenteric vessels. Eur J Radiol, 45 (Suppl. 1): S79-S87.
    • (2003) Eur J Radiol , vol.45 , Issue.SUPPL. 1
    • Fleischmann, D.1
  • 6
    • 0030323970 scopus 로고    scopus 로고
    • A new morphometrical method for measuring the diameter, length and volume of vessels
    • Gielecki J, Cytowski J, Gacek W (1996) A new morphometrical method for measuring the diameter, length and volume of vessels. Folia Morphol, 55: 243-245.
    • (1996) Folia Morphol , vol.55 , pp. 243-245
    • Gielecki, J.1    Cytowski, J.2    Gacek, W.3
  • 7
    • 0017045182 scopus 로고
    • Le polygone de Willis de l'enfant et les facteurs de son modelage
    • Guerin J, Gouaze A, Lazorthes G (1976) Le polygone de Willis de l'enfant et les facteurs de son modelage. Neurochirurgie, 22: 217-226.
    • (1976) Neurochirurgie , vol.22 , pp. 217-226
    • Guerin, J.1    Gouaze, A.2    Lazorthes, G.3
  • 8
    • 0034920604 scopus 로고    scopus 로고
    • Preoperative evaluation of intracranial aneurysms: Usefulness of intraarterial 3D CT angiography and conventional angiography with a combined unit - initial experience
    • Hirai T, Korogi Y, Ono K, Murata Y, Suginohara K, Omori T, Uemura S, Takahashi M (2001) Preoperative evaluation of intracranial aneurysms: usefulness of intraarterial 3D CT angiography and conventional angiography with a combined unit - initial experience. Radiology, 220: 499-505.
    • (2001) Radiology , vol.220 , pp. 499-505
    • Hirai, T.1    Korogi, Y.2    Ono, K.3    Murata, Y.4    Suginohara, K.5    Omori, T.6    Uemura, S.7    Takahashi, M.8
  • 9
    • 9344252304 scopus 로고    scopus 로고
    • Bifurcation asymmetry of the porcine coronary vasculature and its implications on coronary flow heterogeneity
    • Kalsho G, Kassab GS (2004) Bifurcation asymmetry of the porcine coronary vasculature and its implications on coronary flow heterogeneity. Am J Physiol Heart Circ Physiol, 287: 2493-2500.
    • (2004) Am J Physiol Heart Circ Physiol , vol.287 , pp. 2493-2500
    • Kalsho, G.1    Kassab, G.S.2
  • 10
    • 0019412762 scopus 로고
    • Observations on the length and diameter of vessels forming the circle of Willis
    • Kamath S (1981) Observations on the length and diameter of vessels forming the circle of Willis. J Anat, 133: 419-423.
    • (1981) J Anat , vol.133 , pp. 419-423
    • Kamath, S.1
  • 12
    • 0031719086 scopus 로고    scopus 로고
    • Morphometry of the internal thoracic arteries
    • Lachman N, Satyapal KS (1998) Morphometry of the internal thoracic arteries. Surg Radiol Anat, 20: 243-247.
    • (1998) Surg Radiol Anat , vol.20 , pp. 243-247
    • Lachman, N.1    Satyapal, K.S.2
  • 13
    • 0022228970 scopus 로고
    • Asymmetry and anomalies of the circle of Willis in fetal brain. Microsurgical study and functional remarks
    • Milenkovič Z, Vucetič R, Puzič M (1985) Asymmetry and anomalies of the circle of Willis in fetal brain. Microsurgical study and functional remarks. Surg Neurol, 24: 563-570.
    • (1985) Surg Neurol , vol.24 , pp. 563-570
    • Milenkovič, Z.1    Vucetič, R.2    Puzič, M.3
  • 14
    • 0014909541 scopus 로고
    • La circonferenza rettificata delle principali arterie della base dell'encephalo: Ricere statistice su 100 casi umani
    • Orlandini GE (1970) La circonferenza rettificata delle principali arterie della base dell'encephalo: ricere statistice su 100 casi umani. Archio Ital Anat Embriol, 75: 49-79.
    • (1970) Archio Ital Anat Embriol , vol.75 , pp. 49-79
    • Orlandini, G.E.1
  • 15
    • 0022257156 scopus 로고
    • Blood vessel size of circulus arteriosus cerebri (circle of Willis): A statistical research on 100 human subjects
    • Orlandini GE, Ruggiero C, Orlandini SZ, Gulisano M (1985) Blood vessel size of circulus arteriosus cerebri (circle of Willis): a statistical research on 100 human subjects. Acta Anat (Basel), 123: 72-76.
    • (1985) Acta Anat (Basel) , vol.123 , pp. 72-76
    • Orlandini, G.E.1    Ruggiero, C.2    Orlandini, S.Z.3    Gulisano, M.4
  • 16
    • 0003827653 scopus 로고    scopus 로고
    • Second edition. Lippincott Williams and Wilkins, Philadelphia
    • Osborn AG (1999) Diagnostic cerebral angiography. Second edition. Lippincott Williams and Wilkins, Philadelphia.
    • (1999) Diagnostic cerebral angiography
    • Osborn, A.G.1
  • 17
    • 0025884952 scopus 로고
    • A comparative study of the circle of Willis in fetal and adult life. The configuration of the posterior bifurcation of the posterior communicating artery
    • van Overbeeke JJ, Hillen B, Tulleken CA (1991) A comparative study of the circle of Willis in fetal and adult life. The configuration of the posterior bifurcation of the posterior communicating artery. J Anat, 176: 45-54.
    • (1991) J Anat , vol.176 , pp. 45-54
    • van Overbeeke, J.J.1    Hillen, B.2    Tulleken, C.A.3
  • 18
    • 0019831112 scopus 로고
    • Statistical research on the corrected circumference variations of some human arteries related to sex, side and age
    • Pacini P, Gulisano M, Zecchi S, Orlandini GE (1981) Statistical research on the corrected circumference variations of some human arteries related to sex, side and age. Boll Soc Ital Biol Sper, 57: 595-599.
    • (1981) Boll Soc Ital Biol Sper , vol.57 , pp. 595-599
    • Pacini, P.1    Gulisano, M.2    Zecchi, S.3    Orlandini, G.E.4
  • 19
    • 27744489391 scopus 로고    scopus 로고
    • Microsurgical anatomy of the middle cerebral artery
    • Pai SB, Varma RG, Kulkarni RN (2005) Microsurgical anatomy of the middle cerebral artery. Neurol India, 53: 186-190.
    • (2005) Neurol India , vol.53 , pp. 186-190
    • Pai, S.B.1    Varma, R.G.2    Kulkarni, R.N.3
  • 20
    • 33744717407 scopus 로고
    • A study in the quantification of the circle of Willis
    • Pallie W, Samarasinghe D (1962) A study in the quantification of the circle of Willis. Brain, 85: 569-578.
    • (1962) Brain , vol.85 , pp. 569-578
    • Pallie, W.1    Samarasinghe, D.2
  • 21
    • 0017072827 scopus 로고
    • Microsurgical anatomy of the anterior cerebral -anterior communicating recurrent artery complex
    • Perlmutter D, Rhoton AL (1976) Microsurgical anatomy of the anterior cerebral -anterior communicating recurrent artery complex. J Neurosurg, 45: 259-272.
    • (1976) J Neurosurg , vol.45 , pp. 259-272
    • Perlmutter, D.1    Rhoton, A.L.2
  • 22
    • 0017231319 scopus 로고
    • Variation in form of circle of Willis: Some anatomical and embryological considerations
    • Puchades-Orts A, Nombela-Gomez M, Ortuno-Pacheco G (1976) Variation in form of circle of Willis: some anatomical and embryological considerations. Anat Rec, 185: 119-123.
    • (1976) Anat Rec , vol.185 , pp. 119-123
    • Puchades-Orts, A.1    Nombela-Gomez, M.2    Ortuno-Pacheco, G.3
  • 23
    • 73649191389 scopus 로고
    • Variation in form of circle of Willis. The relation of the variations to collateral circulation: Anatomic analysis
    • Riggs HE, Rupp C (1963) Variation in form of circle of Willis. The relation of the variations to collateral circulation: anatomic analysis. Arch Neurol, 8: 8-14.
    • (1963) Arch Neurol , vol.8 , pp. 8-14
    • Riggs, H.E.1    Rupp, C.2
  • 24
    • 0012443905 scopus 로고
    • The diameters of the cerebral arteries of the human fetus
    • Seydel HG (1964) The diameters of the cerebral arteries of the human fetus. Anat Rec, 150: 79-88.
    • (1964) Anat Rec , vol.150 , pp. 79-88
    • Seydel, H.G.1
  • 25
    • 0018104382 scopus 로고
    • Geometric anatomy of the aortic-common iliac bifurcation
    • Shah PM, Scarton HA, Tsapogas MJ (1978) Geometric anatomy of the aortic-common iliac bifurcation. J Anat, 126: 451-458.
    • (1978) J Anat , vol.126 , pp. 451-458
    • Shah, P.M.1    Scarton, H.A.2    Tsapogas, M.J.3
  • 26
    • 0343069202 scopus 로고
    • Aneurysms and anatomical variation of cerebral arteries
    • Stehbens WE (1963) Aneurysms and anatomical variation of cerebral arteries. Arch Pathol, 75: 45-64.
    • (1963) Arch Pathol , vol.75 , pp. 45-64
    • Stehbens, W.E.1
  • 27
    • 0029815222 scopus 로고    scopus 로고
    • Anatomic evaluation of the circle of Willis: MR angiography versus intraarterial digital subtraction angiography
    • Stock KW, Wetzel S, Kirsch E, Bongartz G, Steinbrich W, Radue EW (1996) Anatomic evaluation of the circle of Willis: MR angiography versus intraarterial digital subtraction angiography. Am J Neuroradiol, 17: 1495-1499.
    • (1996) Am J Neuroradiol , vol.17 , pp. 1495-1499
    • Stock, K.W.1    Wetzel, S.2    Kirsch, E.3    Bongartz, G.4    Steinbrich, W.5    Radue, E.W.6
  • 28
    • 0035287316 scopus 로고    scopus 로고
    • Three-dimensional volume-rendered CT angiography of the renal arteries and veins: Normal anatomy, variants, and clinical applications
    • Urban BA, Ratner LE, Fishman EK (2001) Three-dimensional volume-rendered CT angiography of the renal arteries and veins: normal anatomy, variants, and clinical applications. Radiographics, 21: 373-386.
    • (2001) Radiographics , vol.21 , pp. 373-386
    • Urban, B.A.1    Ratner, L.E.2    Fishman, E.K.3
  • 29
    • 0036933451 scopus 로고    scopus 로고
    • Comparative morphological variations and abnormalities of circles of Willis: A minireview including two personal cases
    • Vasovič L, Milenkovič Z, Pavlovič S (2002) Comparative morphological variations and abnormalities of circles of Willis: a minireview including two personal cases. Neurosurg Rev, 25: 247-251.
    • (2002) Neurosurg Rev , vol.25 , pp. 247-251
    • Vasovič, L.1    Milenkovič, Z.2    Pavlovič, S.3
  • 30
    • 0035313193 scopus 로고    scopus 로고
    • Magnetic resonance angiography of the intracranial vessels
    • Wilms G, Bosmans H, Demaerel P, Marchal G (2001) Magnetic resonance angiography of the intracranial vessels. Eur J Radiol, 38: 10-18.
    • (2001) Eur J Radiol , vol.38 , pp. 10-18
    • Wilms, G.1    Bosmans, H.2    Demaerel, P.3    Marchal, G.4
  • 31
    • 0034888698 scopus 로고    scopus 로고
    • Intracranial aneurysms: Evaluation in 200 patients with spiral CT angiography
    • Young N, Dorsch NW, Kingston RJ, Markson G, McMahon J (2001) Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography. Eur Radiol, 11: 123-130.
    • (2001) Eur Radiol , vol.11 , pp. 123-130
    • Young, N.1    Dorsch, N.W.2    Kingston, R.J.3    Markson, G.4    McMahon, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.