메뉴 건너뛰기




Volumn 27, Issue 1, 2008, Pages 24-29

Comparing tympanic temperatures in both ears to oral temperature in the critically ill adult

(1)  Spitzer, Olinda P a  

a NONE   (United States)

Author keywords

Fever; Temperature measurement; Tympanic temperature

Indexed keywords

ADULT; AGED; ARTICLE; BODY TEMPERATURE; CALIBRATION; CLINICAL NURSING RESEARCH; COMPARATIVE STUDY; CRITICAL ILLNESS; EARDRUM; EPIDEMIOLOGY; FEMALE; FEVER; HUMAN; INSTRUMENTATION; INTENSIVE CARE; MALE; METHODOLOGY; MIDDLE AGED; MONITORING; MOUTH MUCOSA; NURSING; NURSING ASSESSMENT; REGRESSION ANALYSIS; STANDARD; STATISTICAL MODEL; THERMOGRAPHY; VALIDATION STUDY;

EID: 37349107045     PISSN: 07304625     EISSN: 15388646     Source Type: Journal    
DOI: 10.1097/01.DCC.0000304671.83874.05     Document Type: Article
Times cited : (5)

References (18)
  • 1
    • 0027490828 scopus 로고
    • A comparison of pulmonary artery, rectal, and tympanic membrane temperature measurement in the ICU
    • Klein D, Mitchell C, Petriner A, et al. A comparison of pulmonary artery, rectal, and tympanic membrane temperature measurement in the ICU. Heart Lung. 1993;22:435-441.
    • (1993) Heart Lung , vol.22 , pp. 435-441
    • Klein, D.1    Mitchell, C.2    Petriner, A.3
  • 2
    • 0032735007 scopus 로고    scopus 로고
    • Temperature measurement in critically ill orally intubated adults: A comparison of pulmonary artery core, tympanic and oral methods
    • Giuliano K, Scott S, Elliot S, Giuliano A. Temperature measurement in critically ill orally intubated adults: a comparison of pulmonary artery core, tympanic and oral methods. Crit Care Med. 1999;27:2188-2193.
    • (1999) Crit Care Med , vol.27 , pp. 2188-2193
    • Giuliano, K.1    Scott, S.2    Elliot, S.3    Giuliano, A.4
  • 3
    • 0026129737 scopus 로고
    • Comparison of tympanic and oral temperatures in surgical patients
    • Erickson R, Yount S. Comparison of tympanic and oral temperatures in surgical patients. Nurs Res. 1991;40:90-93.
    • (1991) Nurs Res , vol.40 , pp. 90-93
    • Erickson, R.1    Yount, S.2
  • 4
    • 0029444687 scopus 로고
    • Effect of cerumen on infrared ear temperature measurement
    • Hasel L, Erickson R. Effect of cerumen on infrared ear temperature measurement. J Gerontol Nurs. 1995;1:6-13.
    • (1995) J Gerontol Nurs , vol.1 , pp. 6-13
    • Hasel, L.1    Erickson, R.2
  • 5
    • 0028276301 scopus 로고
    • Accuracy of infrared ear thermometry and traditional methods in young children
    • Erickson R, Woo T. Accuracy of infrared ear thermometry and traditional methods in young children. Heart Lung. 1994;23:181-194.
    • (1994) Heart Lung , vol.23 , pp. 181-194
    • Erickson, R.1    Woo, T.2
  • 6
    • 5144234077 scopus 로고    scopus 로고
    • Reviewing the effectiveness of tympanic temperatures
    • Gallimore D. Reviewing the effectiveness of tympanic temperatures. Nurs Time. 2004;100:32-34.
    • (2004) Nurs Time , vol.100 , pp. 32-34
    • Gallimore, D.1
  • 7
    • 0032978024 scopus 로고    scopus 로고
    • Tympanic membrane temperature as a measure of core temperature
    • Available at:, Accessed June
    • Childs C, Harrison R, Hodkinson C. Tympanic membrane temperature as a measure of core temperature. Arch Dis Child [serial online]. 1999;80:262-266. Available at: www.archdischild.com/cgi. Accessed June 2006.
    • (2006) Arch Dis Child [serial online]. 1999 , vol.80 , pp. 262-266
    • Childs, C.1    Harrison, R.2    Hodkinson, C.3
  • 8
    • 0034223069 scopus 로고    scopus 로고
    • Temperature measurements in critically ill adults: A comparison of tympanic and oral methods
    • Giuliano K, Giuliano A, Scott S, et al. Temperature measurements in critically ill adults: a comparison of tympanic and oral methods. Am J Crit Care. 2000;9:254-261.
    • (2000) Am J Crit Care , vol.9 , pp. 254-261
    • Giuliano, K.1    Giuliano, A.2    Scott, S.3
  • 9
    • 37349031338 scopus 로고    scopus 로고
    • Intelligent Medical Systems. Ear Thermometry: A FirsTemp Clinical Monograph. St Louis, Mo: Sherwood-Davis & Geck; 1991.
    • Intelligent Medical Systems. Ear Thermometry: A FirsTemp Clinical Monograph. St Louis, Mo: Sherwood-Davis & Geck; 1991.
  • 10
    • 31544460815 scopus 로고    scopus 로고
    • Ear and oral temperatures under usual practice conditions
    • Lee V, McKenzie N, Cathcart M. Ear and oral temperatures under usual practice conditions. Res Nurs Pract. 1999;(1):1-7.
    • (1999) Res Nurs Pract , vol.1 , pp. 1-7
    • Lee, V.1    McKenzie, N.2    Cathcart, M.3
  • 11
    • 0026910424 scopus 로고
    • Can you rely on tympanic thermometers?
    • Baird S, White N, Basinger M. Can you rely on tympanic thermometers? RN. 1992;48:50-51.
    • (1992) RN , vol.48 , pp. 50-51
    • Baird, S.1    White, N.2    Basinger, M.3
  • 12
    • 0038161055 scopus 로고    scopus 로고
    • The utility of tympanic versus oral temperature measurements of firefighters in emergency incident rehabilitation operations
    • Dickinson E, Bevilacqua J, Hill J, et al. The utility of tympanic versus oral temperature measurements of firefighters in emergency incident rehabilitation operations. Prehosp Emerg Care. 2003;7:363-367.
    • (2003) Prehosp Emerg Care , vol.7 , pp. 363-367
    • Dickinson, E.1    Bevilacqua, J.2    Hill, J.3
  • 13
    • 0031855749 scopus 로고    scopus 로고
    • Lack of agreement between tympanic and oral temperature measurements in adult hospitalized patients
    • Manian F, Griesenauer S. Lack of agreement between tympanic and oral temperature measurements in adult hospitalized patients. Am J Infect Control. 1998;26:428-430.
    • (1998) Am J Infect Control , vol.26 , pp. 428-430
    • Manian, F.1    Griesenauer, S.2
  • 14
    • 37349091020 scopus 로고    scopus 로고
    • Temperature measurements in critically ill adults
    • Lawson L, Bridges E, Ballou I, et al. Temperature measurements in critically ill adults. Am J Crit Care. 2006;15:332-333.
    • (2006) Am J Crit Care , vol.15 , pp. 332-333
    • Lawson, L.1    Bridges, E.2    Ballou, I.3
  • 15
    • 0019017392 scopus 로고
    • Oral temperature differences in relation to thermometer and technique
    • Erickson R. Oral temperature differences in relation to thermometer and technique. Nurs Res. 1980;29:157-164.
    • (1980) Nurs Res , vol.29 , pp. 157-164
    • Erickson, R.1
  • 16
    • 0036481650 scopus 로고    scopus 로고
    • Comparison of oral and tympanic temperatures in adult surgical patients
    • Gilbert M, Barton A, Counsell C. Comparison of oral and tympanic temperatures in adult surgical patients. Appl Nurs Res. 2002;15:42-47.
    • (2002) Appl Nurs Res , vol.15 , pp. 42-47
    • Gilbert, M.1    Barton, A.2    Counsell, C.3
  • 17
    • 37349103705 scopus 로고    scopus 로고
    • Tyco Healthcare. Trouble shooting guide: FirsTemp Genius Infrared Thermometry. Tyco Health [serial online]. 2004:1-3. Available at: www.tyco.org. Accessed June 1, 2006.
    • Tyco Healthcare. Trouble shooting guide: FirsTemp Genius Infrared Thermometry. Tyco Health [serial online]. 2004:1-3. Available at: www.tyco.org. Accessed June 1, 2006.
  • 18
    • 37349013821 scopus 로고    scopus 로고
    • Available at:, Accessed May 23
    • Trombley J, Lanhan, D. Pediatr Nur. 1999. Available at: www.ajj.com/services/pblshng/pnj/authorindex.html. Accessed May 23, 2007.
    • (2007) Pediatr Nur. 1999
    • Trombley, J.1    Lanhan, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.