Volumn 55, Issue 1, 2008, Pages 372-375

The single nerve fiber action potential and the filter bank - A modeling approach

Author keywords

Cuff electrodes; Filter bank; Nerve signal; Single fiber action potentials; Wavelet

Indexed keywords

ELECTRODES; NEUROLOGY; PHYSIOLOGICAL MODELS; VELOCITY MEASUREMENT; WAVELET ANALYSIS;

EID: 37349082040     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2007.903518     Document Type: Article
Times cited : (6)

References (13)
  • 1
    • 0031001817 scopus 로고    scopus 로고
    • The extracellular potential of a myelinated nerve fiber in an unbounded medium and in nerve cuff models
    • J. J. Struijk, "The extracellular potential of a myelinated nerve fiber in an unbounded medium and in nerve cuff models," Biophys. J., vol. 72, pp. 2457-2469, 1997.
    • (1997) Biophys. J , vol.72 , pp. 2457-2469
    • Struijk, J.J.1
  • 2
    • 0034233548 scopus 로고    scopus 로고
    • Measurement of the performance of nerve cuff electrodes for recording
    • L. N. S. Andreasen, J. J. Struijk, and S. Lawrence, "Measurement of the performance of nerve cuff electrodes for recording," Med. Biol. Eng. Comp., vol. 38, pp. 447-453, 2000.
    • (2000) Med. Biol. Eng. Comp , vol.38 , pp. 447-453
    • Andreasen, L.N.S.1    Struijk, J.J.2    Lawrence, S.3
  • 3
    • 0029510632 scopus 로고
    • Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
    • M. K. Haugland and T. Sinkjær, "Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man," IEEE Trans. Rehab. Eng., vol. 3, pp. 307-317, 1995.
    • (1995) IEEE Trans. Rehab. Eng , vol.3 , pp. 307-317
    • Haugland, M.K.1    Sinkjær, T.2
  • 6
    • 0032102982 scopus 로고    scopus 로고
    • Digital signal processing algorithms for detection of afferent nerve activity recorded from cuff electrodes
    • B. Upshaw and T. Sinkjær, "Digital signal processing algorithms for detection of afferent nerve activity recorded from cuff electrodes," IEEE Trans. Rehab. Eng., vol. 6, pp. 172-181, 1998.
    • (1998) IEEE Trans. Rehab. Eng , vol.6 , pp. 172-181
    • Upshaw, B.1    Sinkjær, T.2
  • 7
    • 0034968266 scopus 로고    scopus 로고
    • Neurofuzzy extraction of angular information from muscle afferents for ankle control during standing in paraplegic subjects: An animal model
    • S. Micera, W. Jensen, F. Sepulveda, R. Riso, and T. Sinkjær, "Neurofuzzy extraction of angular information from muscle afferents for ankle control during standing in paraplegic subjects: An animal model," IEEE Trans. Biomed. Eng., vol. 48, pp. 787-794, 2001.
    • (2001) IEEE Trans. Biomed. Eng , vol.48 , pp. 787-794
    • Micera, S.1    Jensen, W.2    Sepulveda, F.3    Riso, R.4    Sinkjær, T.5
  • 8
    • 0344063414 scopus 로고    scopus 로고
    • Skin contact forces extracted from human nerve signals -Apossible feedback signal for FES aided control of standing
    • L. N. S. Andreasen and J. J. Struijk, "Skin contact forces extracted from human nerve signals -Apossible feedback signal for FES aided control of standing," IEEE Trans. Biomed. Eng., vol. 50, pp. 1320-1325, 2003.
    • (2003) IEEE Trans. Biomed. Eng , vol.50 , pp. 1320-1325
    • Andreasen, L.N.S.1    Struijk, J.J.2
  • 9
    • 0024700097 scopus 로고
    • A theory for multiresolution signal decomposition: The wavelet representation
    • S. G. Mallat, "A theory for multiresolution signal decomposition: The wavelet representation," IEEE Trans. Pattern Anal. Machine Intell., vol. 11, pp. 674-693, 1989.
    • (1989) IEEE Trans. Pattern Anal. Machine Intell , vol.11 , pp. 674-693
    • Mallat, S.G.1
  • 10
    • 0026922952 scopus 로고
    • Wavelets and filter banks
    • M. Vetterli, "Wavelets and filter banks," IEEE Trans. Signal Process., vol. 40, pp. 2207-2232, 1992.
    • (1992) IEEE Trans. Signal Process , vol.40 , pp. 2207-2232
    • Vetterli, M.1
  • 12
    • 0036721509 scopus 로고    scopus 로고
    • Signal strength versus cuff length in nerve cuff electrode recordings
    • L. N. S. Andreasen and J. J. S. Struijk, "Signal strength versus cuff length in nerve cuff electrode recordings," IEEE Trans. Biomed. Eng., vol. 49, pp. 1045-1050, 2002.
    • (2002) IEEE Trans. Biomed. Eng , vol.49 , pp. 1045-1050
    • Andreasen, L.N.S.1    Struijk, J.J.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.