메뉴 건너뛰기




Volumn 55, Issue 1, 2008, Pages 257-266

A transcranial magnetic stimulator inducing near-rectangular pulses with controllable pulse width (cTMS)

Author keywords

Bioelectric potentials; Biomagnetics; Biomembranes; Electric fields; Energy measurement; Heating; Insulated gate bipolar transistors; Magnetic fields; Neuromuscular stimulation; Pulse generation; Pulse power systems; Pulse shaping circuits; Pulse width (PW)

Indexed keywords

BIOELECTRIC POTENTIALS; BIOMAGNETISM; ELECTRIC FIELDS; ELECTRIC POWER MEASUREMENT; INSULATED GATE BIPOLAR TRANSISTORS (IGBT); MAGNETIC FIELDS; PULSE GENERATORS; PULSE SHAPING CIRCUITS;

EID: 37349045082     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2007.900540     Document Type: Article
Times cited : (135)

References (25)
  • 1
    • 37349073971 scopus 로고    scopus 로고
    • cTMS: A novel TMS device inducing near rectangular pulses with controllable pulse width
    • A. V. Peterchev, T. J. Spellman, and S. H. Lisanby, "cTMS: A novel TMS device inducing near rectangular pulses with controllable pulse width," Neuropsychopharmacology, vol. 31, no. S1, p. S130, 2006.
    • (2006) Neuropsychopharmacology , vol.31 , Issue.S1
    • Peterchev, A.V.1    Spellman, T.J.2    Lisanby, S.H.3
  • 2
    • 0026264364 scopus 로고
    • Magnetic nerve stimulation: The effect of waveform on efficiency, determination of neural membrane time constants and the measurement of stimulator output
    • A. T. Barker, C. W. Garnham, and I. L. Freeston, "Magnetic nerve stimulation: The effect of waveform on efficiency, determination of neural membrane time constants and the measurement of stimulator output," Electroencephalogr. Clin. Neurophysiol. Suppl., vol. 43, pp. 227-237, 1991.
    • (1991) Electroencephalogr. Clin. Neurophysiol. Suppl , vol.43 , pp. 227-237
    • Barker, A.T.1    Garnham, C.W.2    Freeston, I.L.3
  • 3
    • 0026594870 scopus 로고
    • Relevance of stimulus duration for activation of motor and sensory fibers: Implications for the study of H-reflexes and magnetic stimulation
    • M. Panizza, J. Nilsson, B. J. Roth, P. J. Basser, and M. Hallett, "Relevance of stimulus duration for activation of motor and sensory fibers: Implications for the study of H-reflexes and magnetic stimulation," Electroencephalogr. Clin. Neurophysiol. Suppl., vol. 85, no. 1, pp. 22-29, 1992.
    • (1992) Electroencephalogr. Clin. Neurophysiol. Suppl , vol.85 , Issue.1 , pp. 22-29
    • Panizza, M.1    Nilsson, J.2    Roth, B.J.3    Basser, P.J.4    Hallett, M.5
  • 4
    • 37349109543 scopus 로고    scopus 로고
    • Central condution time studies
    • A. Pascual-Leone, N. J. Davey, J. Rothwell, E. M. Wassermann, and B. K. Puri, Eds. London, U.K, Arnold
    • P. M. Rossini and F. Pauri, "Central condution time studies," in Handbook of Transcranial Magnetic Stimulation, A. Pascual-Leone, N. J. Davey, J. Rothwell, E. M. Wassermann, and B. K. Puri, Eds. London, U.K.: Arnold, 2002, pp. 90-96.
    • (2002) Handbook of Transcranial Magnetic Stimulation , pp. 90-96
    • Rossini, P.M.1    Pauri, F.2
  • 5
    • 0023210001 scopus 로고
    • Optimal stimulus duration for extracranial cortical stimulation
    • L. A. Geddes, "Optimal stimulus duration for extracranial cortical stimulation," Neurosurgery, vol. 20, no. 1, pp. 94-99, 1987.
    • (1987) Neurosurgery , vol.20 , Issue.1 , pp. 94-99
    • Geddes, L.A.1
  • 6
    • 0021802893 scopus 로고
    • Non-invasive magnetic stimulation of human motor cortex
    • A. T. Barker, R. Jalinous, and I. L. Freeston, "Non-invasive magnetic stimulation of human motor cortex," Lancet, vol. 1, no. 8437, pp. 1106-7, 1985.
    • (1985) Lancet , vol.1 , Issue.8437 , pp. 1106-1107
    • Barker, A.T.1    Jalinous, R.2    Freeston, I.L.3
  • 7
    • 19444387567 scopus 로고    scopus 로고
    • Principles of magnetic stimulator design
    • A. Pascual-Leone, N. J. Davey, J. Rothwell, E. M. Wassermann, and B. K. Puri, Eds. London, U.K, Arnold
    • R. Jalinous, "Principles of magnetic stimulator design," in Handbook of Transcranial Magnetic Stimulation, A. Pascual-Leone, N. J. Davey, J. Rothwell, E. M. Wassermann, and B. K. Puri, Eds. London, U.K.: Arnold, 2002, pp. 30-38.
    • (2002) Handbook of Transcranial Magnetic Stimulation , pp. 30-38
    • Jalinous, R.1
  • 9
    • 37349090645 scopus 로고    scopus 로고
    • MagPro X100 user guide including MagOption, Medtronic A/S, 2003.
    • MagPro X100 user guide including MagOption, Medtronic A/S, 2003.
  • 10
    • 0025975115 scopus 로고
    • Technical and practical aspects of magnetic nerve stimulation
    • R. Jalinous, "Technical and practical aspects of magnetic nerve stimulation," J. Clin. Neurophysiol., vol. 8, no. 1, pp. 10-25, 1991.
    • (1991) J. Clin. Neurophysiol , vol.8 , Issue.1 , pp. 10-25
    • Jalinous, R.1
  • 11
    • 17644398190 scopus 로고    scopus 로고
    • Magnetic seizure therapy: Development of a novel intervention for treatment resistant depression
    • O. G. Morales, H. A. Sackeim, R. M. Berman, and S. H. Lisanby, "Magnetic seizure therapy: development of a novel intervention for treatment resistant depression," Clin. Neurosci. Res., vol. 4, pp. 59-70, 2004.
    • (2004) Clin. Neurosci. Res , vol.4 , pp. 59-70
    • Morales, O.G.1    Sackeim, H.A.2    Berman, R.M.3    Lisanby, S.H.4
  • 12
    • 0034779924 scopus 로고    scopus 로고
    • Transcranial magnetic stimulation: Which part of the current waveform causes the stimulation?
    • E. Corthout, A. T. Barker, and A. Cowey, "Transcranial magnetic stimulation: Which part of the current waveform causes the stimulation?," Exp. Brain Res., vol. 141, no. 1, pp. 128-132, 2001.
    • (2001) Exp. Brain Res , vol.141 , Issue.1 , pp. 128-132
    • Corthout, E.1    Barker, A.T.2    Cowey, A.3
  • 13
    • 34548106922 scopus 로고    scopus 로고
    • J. Ruohonen and R. J. Ilmoniemi, Basic physics and design of transcranial magnatic stimulation devices and coils, in Magnetic Stimulation in Clinical Neurophysiology, M. Hallett and S. Chokroverty, Eds., 2nd ed. Philadelphia, PA: Elsevier Butterworth-Heinemann, 2005, pp. 17-30.
    • J. Ruohonen and R. J. Ilmoniemi, "Basic physics and design of transcranial magnatic stimulation devices and coils," in Magnetic Stimulation in Clinical Neurophysiology, M. Hallett and S. Chokroverty, Eds., 2nd ed. Philadelphia, PA: Elsevier Butterworth-Heinemann, 2005, pp. 17-30.
  • 18
    • 0031930002 scopus 로고    scopus 로고
    • Risk and safety of repetitive transcranial magnetic stimulation: Report and suggested guidelines from the international workshop on the safety of repetitive transcranial magnetic stimulation, June 5-7, 1996
    • E. M. Wassermann, "Risk and safety of repetitive transcranial magnetic stimulation: Report and suggested guidelines from the international workshop on the safety of repetitive transcranial magnetic stimulation, June 5-7, 1996," Electroencephalogr. Clin. Neurophysiol., vol. 108, no. 1, pp. 1-16, 1998.
    • (1998) Electroencephalogr. Clin. Neurophysiol , vol.108 , Issue.1 , pp. 1-16
    • Wassermann, E.M.1
  • 19
    • 0347292901 scopus 로고    scopus 로고
    • Safety and side-effects of transcranial magnetic stimulation and repetitive transcranial magnetic stimulation
    • A. Pascual-Leone, N. J. Davey, J. Rothwell, E. M. Wassermann, and B. K. Puri, Eds. London, U.K, Arnold
    • E. M. Wassermann, "Safety and side-effects of transcranial magnetic stimulation and repetitive transcranial magnetic stimulation," in Handbook of Transcranial Magnetic Stimulation, A. Pascual-Leone, N. J. Davey, J. Rothwell, E. M. Wassermann, and B. K. Puri, Eds. London, U.K.: Arnold, 2002, pp. 39-49.
    • (2002) Handbook of Transcranial Magnetic Stimulation , pp. 39-49
    • Wassermann, E.M.1
  • 20
    • 0023209822 scopus 로고
    • Considerations for safety in the use of extracranial stimulation for motor evoked potentials
    • W. F. Agnew and D. B. McCreery, "Considerations for safety in the use of extracranial stimulation for motor evoked potentials," Neurosurgery, vol. 20, no. 1, pp. 143-147, 1987.
    • (1987) Neurosurgery , vol.20 , Issue.1 , pp. 143-147
    • Agnew, W.F.1    McCreery, D.B.2
  • 21
    • 0037035561 scopus 로고    scopus 로고
    • Neuronal tissue polarization induced by repetitive transcranial magnetic stimulation?
    • M. Sommer, N. Lang, F. Tergau, and W. Paulus, "Neuronal tissue polarization induced by repetitive transcranial magnetic stimulation?," Neuroreport, vol. 13, no. 6, pp. 809-811, 2002.
    • (2002) Neuroreport , vol.13 , Issue.6 , pp. 809-811
    • Sommer, M.1    Lang, N.2    Tergau, F.3    Paulus, W.4
  • 22
    • 0037016173 scopus 로고    scopus 로고
    • Pulse configuration-dependent effects of repetitive transcranial magnetic stimulation on visual perception
    • A. Antal, T. Z. Kincses, M. A. Nitsche, O. Bartfai, I. Demmer, M. Sommer, and W. Paulus, "Pulse configuration-dependent effects of repetitive transcranial magnetic stimulation on visual perception," Neuroreport, vol. 13, no. 17, pp. 2229-2233, 2002.
    • (2002) Neuroreport , vol.13 , Issue.17 , pp. 2229-2233
    • Antal, A.1    Kincses, T.Z.2    Nitsche, M.A.3    Bartfai, O.4    Demmer, I.5    Sommer, M.6    Paulus, W.7
  • 23
    • 23744489867 scopus 로고    scopus 로고
    • Orientation-specific fast rTMS maximizes corticospinal inhibition and facilitation
    • T. Tings, N. Lang, F. Tergau, W. Paulus, and M. Sommer, "Orientation-specific fast rTMS maximizes corticospinal inhibition and facilitation," Exp. Brain Res., vol. 164, no. 3, pp. 323-333, 2005.
    • (2005) Exp. Brain Res , vol.164 , Issue.3 , pp. 323-333
    • Tings, T.1    Lang, N.2    Tergau, F.3    Paulus, W.4    Sommer, M.5
  • 24
    • 13844298779 scopus 로고    scopus 로고
    • Comparison between short train, monophasic and biphasic repetitive transcranial magnetic stimulation (rTMS) of the human motor cortex
    • N. Arai, S. Okabe, T. Furubayashi, Y. Terao, K. Yuasa, and Y. Ugawa, "Comparison between short train, monophasic and biphasic repetitive transcranial magnetic stimulation (rTMS) of the human motor cortex," Clin. Neurophysiol., vol. 116, no. 3, pp. 605-613, 2005.
    • (2005) Clin. Neurophysiol , vol.116 , Issue.3 , pp. 605-613
    • Arai, N.1    Okabe, S.2    Furubayashi, T.3    Terao, Y.4    Yuasa, K.5    Ugawa, Y.6
  • 25
    • 33845598032 scopus 로고    scopus 로고
    • Stimulus waveform influences the efficacy of repetitive transcranial magnetic stimulation
    • J. L. Taylor and C. K. Loo, "Stimulus waveform influences the efficacy of repetitive transcranial magnetic stimulation," J. Affect Disord., vol. 97, pp. 271-276, 2007.
    • (2007) J. Affect Disord , vol.97 , pp. 271-276
    • Taylor, J.L.1    Loo, C.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.