메뉴 건너뛰기




Volumn 55, Issue 1, 2008, Pages 171-180

Arterial vulnerable plaque characterization using ultrasound-induced thermal strain imaging (TSI)

Author keywords

Cardiovascular plaque characterization; Thermal strain imaging; Ultrasound induced thermal strain imaging

Indexed keywords

CORRELATION METHODS; MEDICAL IMAGING; OPTICAL RESOLVING POWER; PHYSIOLOGICAL MODELS; SPECKLE; TISSUE;

EID: 37349036255     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2007.900565     Document Type: Article
Times cited : (40)

References (47)
  • 1
    • 0021847311 scopus 로고
    • Plaque fissuring - The cause of acute myocardial infarction, sudden ischaemic death, and crescendo angina
    • M. J. Davies and A. C. Thomas, "Plaque fissuring - The cause of acute myocardial infarction, sudden ischaemic death, and crescendo angina," British Heart J., vol. 53, pp. 363-73, 1985.
    • (1985) British Heart J , vol.53 , pp. 363-373
    • Davies, M.J.1    Thomas, A.C.2
  • 2
    • 0029054734 scopus 로고
    • Molecular bases of the acute coronary syndromes
    • P. Libby, "Molecular bases of the acute coronary syndromes," Circulation, vol. 91, pp. 2844-50, 1995.
    • (1995) Circulation , vol.91 , pp. 2844-2850
    • Libby, P.1
  • 3
    • 0029090411 scopus 로고
    • Coronary plaque disruption
    • E. Falk, P. K. Shah, and V. Fuster, "Coronary plaque disruption," Circulation, vol. 92, pp. 657-71, 1995.
    • (1995) Circulation , vol.92 , pp. 657-671
    • Falk, E.1    Shah, P.K.2    Fuster, V.3
  • 4
    • 3042990592 scopus 로고    scopus 로고
    • Angiographic evaluation of culprit lesions in acute coronary syndrome: Relation to the original site on previous coronary angiography
    • T. Saito, H. Date, I. Taniguichi, S. Nakamura, H. Oka, Y. Mizuno, K. Noda, S. Yamashita, S. Oshima, and H. Yasue, "Angiographic evaluation of culprit lesions in acute coronary syndrome: Relation to the original site on previous coronary angiography," Jpn. Circulation J., vol. 62, pp. 359-363, 1998.
    • (1998) Jpn. Circulation J , vol.62 , pp. 359-363
    • Saito, T.1    Date, H.2    Taniguichi, I.3    Nakamura, S.4    Oka, H.5    Mizuno, Y.6    Noda, K.7    Yamashita, S.8    Oshima, S.9    Yasue, H.10
  • 5
    • 0032533756 scopus 로고    scopus 로고
    • D. Franzen, U. Sechtem, and H. W. Hopp, Comparison of angioscopic, intravascular ultrasonic, and angiographic detection of thrombus in coronary stenosis, Amer. J. Cardiol., 82, pp. 1273-1275, 1998, A9.
    • D. Franzen, U. Sechtem, and H. W. Hopp, "Comparison of angioscopic, intravascular ultrasonic, and angiographic detection of thrombus in coronary stenosis," Amer. J. Cardiol., vol. 82, pp. 1273-1275, 1998, A9.
  • 6
    • 0030348889 scopus 로고    scopus 로고
    • Strain imaging of coronary arteries with intraluminal ultrasound: Preliminary experimental results
    • B. M. Shapo, J. R. Crowe, R. Erkamp, S. Y. Emelianov, M. J. Eberle, and M. O'Donnell, "Strain imaging of coronary arteries with intraluminal ultrasound: Preliminary experimental results," in Proc. IEEE Ultrasonics Symp., 1996, vol. 96CH35993, pp. 1177-1180.
    • (1996) Proc. IEEE Ultrasonics Symp , vol.96 CH35993 , pp. 1177-1180
    • Shapo, B.M.1    Crowe, J.R.2    Erkamp, R.3    Emelianov, S.Y.4    Eberle, M.J.5    O'Donnell, M.6
  • 7
    • 0034622623 scopus 로고    scopus 로고
    • Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro
    • C. L. de Korte, G. Pasterkamp, A. F. van der Steen, H. A. Woutman, and N. Bom, "Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro," Circulation, vol. 102, pp. 617-23, 2000.
    • (2000) Circulation , vol.102 , pp. 617-623
    • de Korte, C.L.1    Pasterkamp, G.2    van der Steen, A.F.3    Woutman, H.A.4    Bom, N.5
  • 8
    • 0035970098 scopus 로고    scopus 로고
    • Intravascular ultrasound: Novel pathophysiological insights and current clinical applications
    • S. E. Nissen and P. Yock, "Intravascular ultrasound: novel pathophysiological insights and current clinical applications," Circulation, vol. 103, pp. 604-16, 2001.
    • (2001) Circulation , vol.103 , pp. 604-616
    • Nissen, S.E.1    Yock, P.2
  • 10
    • 0037159282 scopus 로고    scopus 로고
    • Coronary plaque classification with intravascular ultrasound radiofrequency data analysis
    • A. Nair, B. D. Kuban, E. M. Tuzcu, P. Schoenhagen, S. E. Nissen, and D. G. Vince, "Coronary plaque classification with intravascular ultrasound radiofrequency data analysis," Circulation, vol. 106, pp. 2200-6, 2002.
    • (2002) Circulation , vol.106 , pp. 2200-2206
    • Nair, A.1    Kuban, B.D.2    Tuzcu, E.M.3    Schoenhagen, P.4    Nissen, S.E.5    Vince, D.G.6
  • 11
    • 0029125146 scopus 로고
    • Prediction of acute coronary syndromes by percutaneous coronary angioscopy in patients with stable angina
    • Y. Uchida, F. Nakamura, T. Tomaru, T. Morita, T. Oshima, T. Sasaki, S. Morizuki, and J. Hirose, "Prediction of acute coronary syndromes by percutaneous coronary angioscopy in patients with stable angina," Amer. Heart J., vol. 130, pp. 195-203, 1995.
    • (1995) Amer. Heart J , vol.130 , pp. 195-203
    • Uchida, Y.1    Nakamura, F.2    Tomaru, T.3    Morita, T.4    Oshima, T.5    Sasaki, T.6    Morizuki, S.7    Hirose, J.8
  • 15
    • 0028488906 scopus 로고
    • Intravascular MR imaging in a porcine animal model
    • A. J. Martin and R. M. Henkelman, "Intravascular MR imaging in a porcine animal model," Magn. Reson. Med., vol. 32, pp. 224-9, 1994.
    • (1994) Magn. Reson. Med , vol.32 , pp. 224-229
    • Martin, A.J.1    Henkelman, R.M.2
  • 18
    • 0023697634 scopus 로고
    • Morphologic and dynamic changes of atherosclerotic plaque at the carotid artery bifurcation: Sequential imaging by real time B-mode ultrasonography
    • J. Weinberger, L. Ramos, J. A. Ambrose, and V. Fuster, "Morphologic and dynamic changes of atherosclerotic plaque at the carotid artery bifurcation: Sequential imaging by real time B-mode ultrasonography," J. Amer. College Cardiol., vol. 12, pp. 1515-1521, 1988.
    • (1988) J. Amer. College Cardiol , vol.12 , pp. 1515-1521
    • Weinberger, J.1    Ramos, L.2    Ambrose, J.A.3    Fuster, V.4
  • 19
    • 0031894262 scopus 로고    scopus 로고
    • A new noninvasive technique for imaging atherosclerotic plaque in the aortic arch of stroke patients by transcutaneous real-time B-mode ultrasonography: An initial report
    • J. Weinberger, S. Azhar, F. Danisi, R. Hayes, and M. Goldman, "A new noninvasive technique for imaging atherosclerotic plaque in the aortic arch of stroke patients by transcutaneous real-time B-mode ultrasonography: An initial report," Stroke, vol. 29, pp. 673-676, 1998.
    • (1998) Stroke , vol.29 , pp. 673-676
    • Weinberger, J.1    Azhar, S.2    Danisi, F.3    Hayes, R.4    Goldman, M.5
  • 20
    • 0034166585 scopus 로고    scopus 로고
    • Diagnostic imaging of thoracic aortic atherosclerosis
    • P. A. Tunick, G. A. Krinsky, V. S. Lee, and I. Kronzon, "Diagnostic imaging of thoracic aortic atherosclerosis," Amer. J. Roentgenol., vol. 174, pp. 1119-1125, 2000.
    • (2000) Amer. J. Roentgenol , vol.174 , pp. 1119-1125
    • Tunick, P.A.1    Krinsky, G.A.2    Lee, V.S.3    Kronzon, I.4
  • 21
    • 0037044418 scopus 로고    scopus 로고
    • Computed tomography and magnetic resonance imaging for noninvasive coronary angiography and plaque imaging: Current and potential future concepts
    • Z. A. Fayad, V. Fuster, K. Nikolaou, and C. Becker, "Computed tomography and magnetic resonance imaging for noninvasive coronary angiography and plaque imaging: Current and potential future concepts," Circulation, vol. 106, pp. 2026-2034, 2002.
    • (2002) Circulation , vol.106 , pp. 2026-2034
    • Fayad, Z.A.1    Fuster, V.2    Nikolaou, K.3    Becker, C.4
  • 22
    • 0347357884 scopus 로고    scopus 로고
    • Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: A segment-based comparison with intravascular ultrasound
    • S. Achenbach, F. Moselewski, D. Ropers, M. Ferencik, U. Hoffmann, B. D. MacNeill, K. Pohle, U. Baum, K. Anders, I. K. Jang, W. G. Daniel, and T. J. Brady, "Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: A segment-based comparison with intravascular ultrasound," Circulation, vol. 109, pp. 14-17, 2004.
    • (2004) Circulation , vol.109 , pp. 14-17
    • Achenbach, S.1    Moselewski, F.2    Ropers, D.3    Ferencik, M.4    Hoffmann, U.5    MacNeill, B.D.6    Pohle, K.7    Baum, U.8    Anders, K.9    Jang, I.K.10    Daniel, W.G.11    Brady, T.J.12
  • 23
    • 0035198705 scopus 로고    scopus 로고
    • The assessment of the vulnerable atherosclerotic plaque using MR imaging: A brief review
    • Z. A. Fayad, "The assessment of the vulnerable atherosclerotic plaque using MR imaging: A brief review," Int. J. Cardiovasc. Imag., vol. 17, pp. 165-177, 2001.
    • (2001) Int. J. Cardiovasc. Imag , vol.17 , pp. 165-177
    • Fayad, Z.A.1
  • 24
    • 0035903242 scopus 로고    scopus 로고
    • Clinical imaging of the high-risk or vulnerable atherosclerotic plaque
    • Z. A. Fayad and V. Fuster, "Clinical imaging of the high-risk or vulnerable atherosclerotic plaque," Circulation Res., vol. 89, pp. 305-16, 2001.
    • (2001) Circulation Res , vol.89 , pp. 305-316
    • Fayad, Z.A.1    Fuster, V.2
  • 25
    • 0021132985 scopus 로고
    • Simple proton spectroscopic imaging
    • W. T. Dixon, "Simple proton spectroscopic imaging," Radiology, vol. 153, pp. 189-194, 1984.
    • (1984) Radiology , vol.153 , pp. 189-194
    • Dixon, W.T.1
  • 26
    • 0026216918 scopus 로고
    • Multipoint Dixon technique for water and fat proton and susceptibility imaging
    • G. H. Glover, "Multipoint Dixon technique for water and fat proton and susceptibility imaging," J. Magn. Reson. Imag., vol. 1, no. 5, pp. 521-530, 1991.
    • (1991) J. Magn. Reson. Imag , vol.1 , Issue.5 , pp. 521-530
    • Glover, G.H.1
  • 27
    • 23244463430 scopus 로고    scopus 로고
    • Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): Application with fast spin-echo imaging
    • S. B. Reeder, A. R. Pineda, Z. Wen, A. Shimakawa, H. Yu, J. H. Brittain, G. E. Gold, C. H. Beaulieu, and N. J. Pelc, "Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): Application with fast spin-echo imaging," Magn. Reson. Med., vol. 54, no. 3, pp. 636-44, 2005.
    • (2005) Magn. Reson. Med , vol.54 , Issue.3 , pp. 636-644
    • Reeder, S.B.1    Pineda, A.R.2    Wen, Z.3    Shimakawa, A.4    Yu, H.5    Brittain, J.H.6    Gold, G.E.7    Beaulieu, C.H.8    Pelc, N.J.9
  • 29
    • 0027516690 scopus 로고
    • Distribution of circumferential stress in ruptured and stable atherosclerotic lesions: A structural analysis with histopathologic correlation
    • G. C. Cheng, H. M. Loree, R. D. Kamm, M. C. Fishbein, and R. T. Lee, "Distribution of circumferential stress in ruptured and stable atherosclerotic lesions: A structural analysis with histopathologic correlation," Circulation, vol. 87, pp. 1179-1187, 1993.
    • (1993) Circulation , vol.87 , pp. 1179-1187
    • Cheng, G.C.1    Loree, H.M.2    Kamm, R.D.3    Fishbein, M.C.4    Lee, R.T.5
  • 30
    • 0027253887 scopus 로고
    • Risk of thrombosis in human atherosclerotic plaques: Role of extracellular lipid, macrophage, and smooth muscle cell content
    • M. J. Davies, P. D. Richardson, N. Woolf, D. R. Katz, and J. Mann, "Risk of thrombosis in human atherosclerotic plaques: Role of extracellular lipid, macrophage, and smooth muscle cell content," British Heart J., vol. 69, pp. 377-381, 1993.
    • (1993) British Heart J , vol.69 , pp. 377-381
    • Davies, M.J.1    Richardson, P.D.2    Woolf, N.3    Katz, D.R.4    Mann, J.5
  • 31
    • 0001754887 scopus 로고    scopus 로고
    • M. J. Crocker, Ed. New York: Wiley, Encyclopedia of acoustics
    • J. C. Bamber, Acoustical Characteristics of Biological Media, M. J. Crocker, Ed. New York: Wiley, 1997, pp. 1703-1726, Encyclopedia of acoustics.
    • (1997) Acoustical Characteristics of Biological Media , pp. 1703-1726
    • Bamber, J.C.1
  • 32
    • 0002018279 scopus 로고
    • Ultrasonic speed as a parameter for noninvasive thermometry
    • New York: Gordon and Breach
    • R. L. Nasoni and T. Bowen, "Ultrasonic speed as a parameter for noninvasive thermometry," in Non-Invasive Temperature Measurement. New York: Gordon and Breach, 1989, pp. 95-107.
    • (1989) Non-Invasive Temperature Measurement , pp. 95-107
    • Nasoni, R.L.1    Bowen, T.2
  • 33
    • 0029794863 scopus 로고    scopus 로고
    • Noninvasive temperature estimation in tissue via ultrasound echo-shifts: Part I. Analytical model
    • R. Maass-Moreno and C. Damaniou, "Noninvasive temperature estimation in tissue via ultrasound echo-shifts: Part I. Analytical model," J. Acoust. Soc. Amer., vol. 100, 1996.
    • (1996) J. Acoust. Soc. Amer , vol.100
    • Maass-Moreno, R.1    Damaniou, C.2
  • 34
    • 23844443513 scopus 로고    scopus 로고
    • Identification of vulnerable atherosclerotic plaque using IVUS-based thermal strain imaging
    • May
    • Y. Shi, R. S. Witte, and M. O'Donnell, "Identification of vulnerable atherosclerotic plaque using IVUS-based thermal strain imaging," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 52, no. 5, pp. 844-850, May 2005.
    • (2005) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.52 , Issue.5 , pp. 844-850
    • Shi, Y.1    Witte, R.S.2    O'Donnell, M.3
  • 36
    • 0442279553 scopus 로고    scopus 로고
    • Ultrasound characterization of coronary artery wall in vitro using temperature-dependent wave speed
    • Dec
    • F. R. Pereira, J. C. Machado, and F. S. Foster, "Ultrasound characterization of coronary artery wall in vitro using temperature-dependent wave speed," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 50, no. 12, pp. 1474-1485, Dec. 2003.
    • (2003) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.50 , Issue.12 , pp. 1474-1485
    • Pereira, F.R.1    Machado, J.C.2    Foster, F.S.3
  • 37
    • 0029347489 scopus 로고
    • Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound
    • Aug
    • R. Seip and E. S. Ebbini, "Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound," IEEE Trans. Biomed. Eng., vol. 42, no. 8, pp. 828-839, Aug. 1995.
    • (1995) IEEE Trans. Biomed. Eng , vol.42 , Issue.8 , pp. 828-839
    • Seip, R.1    Ebbini, E.S.2
  • 38
    • 0032116408 scopus 로고    scopus 로고
    • Two-dimensional temperature estimation using diagnostic ultrasound
    • Jul
    • C. Simon, P. VanBaren, and E. S. Ebbini, "Two-dimensional temperature estimation using diagnostic ultrasound," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 45, no. 4, pp. 1088-1099, Jul. 1998.
    • (1998) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.45 , Issue.4 , pp. 1088-1099
    • Simon, C.1    VanBaren, P.2    Ebbini, E.S.3
  • 39
    • 0036815626 scopus 로고    scopus 로고
    • Fundamental limitations of noninvasive temperature imaging by means of ultrasound echo strain estimation
    • N. Miller, J. Bamber, and P. Meaney, "Fundamental limitations of noninvasive temperature imaging by means of ultrasound echo strain estimation," Ultrasound Med. Biol., vol. 28, no. 10, pp. 1319-1333, 2002.
    • (2002) Ultrasound Med. Biol , vol.28 , Issue.10 , pp. 1319-1333
    • Miller, N.1    Bamber, J.2    Meaney, P.3
  • 40
    • 1842559776 scopus 로고    scopus 로고
    • Imaging of temperature-induced echo strain: Preliminary in vitro study to assess feasibility for guiding focused ultrasound surgery
    • N. R. Miller, J. C. Bamber, and G. R. Ter Haar, "Imaging of temperature-induced echo strain: Preliminary in vitro study to assess feasibility for guiding focused ultrasound surgery," Ultrasound Med. Biol., vol. 30, no. 3, pp. 345-356, 2004.
    • (2004) Ultrasound Med. Biol , vol.30 , Issue.3 , pp. 345-356
    • Miller, N.R.1    Bamber, J.C.2    Ter Haar, G.R.3
  • 42
    • 33845422459 scopus 로고    scopus 로고
    • A low cost compact 512 channel therapeutic ultrasound system for transcutaneous ultrasound surgery
    • T. Hall and C. A. Cain, "A low cost compact 512 channel therapeutic ultrasound system for transcutaneous ultrasound surgery," in Proc. 5th Int. Symp. Therapeutic Ultrasound, 2006, vol. 829, pp. 445-449.
    • (2006) Proc. 5th Int. Symp. Therapeutic Ultrasound , vol.829 , pp. 445-449
    • Hall, T.1    Cain, C.A.2
  • 44
    • 0032785966 scopus 로고    scopus 로고
    • Speckle tracking methods for ultrasonic elasticity imaging using short time correlation
    • Jan
    • M. A. Lubinski, S. Y. Emelianov, and M. O'Donnell, "Speckle tracking methods for ultrasonic elasticity imaging using short time correlation," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 46, no. 1, pp. 82-96, Jan. 1999.
    • (1999) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.46 , Issue.1 , pp. 82-96
    • Lubinski, M.A.1    Emelianov, S.Y.2    O'Donnell, M.3
  • 45
    • 33644661136 scopus 로고    scopus 로고
    • Cost-effective assembly of a basic fiber-optic hydrophone for measurement of high-amplitude therapeutic ultrasound fields
    • J. E. Parsons, C. A. Cain, and J. B. Fowlkes, "Cost-effective assembly of a basic fiber-optic hydrophone for measurement of high-amplitude therapeutic ultrasound fields," J. Acoust. Soc. Amer., vol. 119, no. 3, pp. 1432-40, 2006.
    • (2006) J. Acoust. Soc. Amer , vol.119 , Issue.3 , pp. 1432-1440
    • Parsons, J.E.1    Cain, C.A.2    Fowlkes, J.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.