Volumn 23, Issue 1, 2008, Pages 123-127

The Agreement and Repeatability of Computer-Based Wear Measurement of Total Hip Arthroplasties

Author keywords

reproducibility; total hip arthroplasty; wear

Indexed keywords

ACCURACY; ARTICLE; CLINICAL ARTICLE; COMPUTER PROGRAM; CONTROLLED STUDY; FOLLOW UP; HUMAN; INTERMETHOD COMPARISON; MEASUREMENT; MEDICAL STUDENT; SURGEON; TOTAL HIP PROSTHESIS; VALIDITY;

EID: 37349006840     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2006.12.106     Document Type: Article
Times cited : (1)

References (13)
  • 1
    • 4544290225 scopus 로고    scopus 로고
    • Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty
    • González Della Valle A., Zoppi A., Peterson M., et al. Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty. J Bone Joint Surg Am 86 (2004) 1998
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 1998
    • González Della Valle, A.1    Zoppi, A.2    Peterson, M.3
  • 2
    • 27644475315 scopus 로고    scopus 로고
    • Backside wear is low in modern modular and non-modular acetabular liners
    • González Della Valle A., Rana A., Furman B., et al. Backside wear is low in modern modular and non-modular acetabular liners. Clin Orthop 440 (2005) 184
    • (2005) Clin Orthop , vol.440 , pp. 184
    • González Della Valle, A.1    Rana, A.2    Furman, B.3
  • 3
    • 0038351037 scopus 로고    scopus 로고
    • Relationship between polyethylene wear and osteolysis in hips with a second-generation porous-coated cementless cup after seven years of follow-up
    • Orishimo K.F., Claus A.M., Sychterz C.J., et al. Relationship between polyethylene wear and osteolysis in hips with a second-generation porous-coated cementless cup after seven years of follow-up. J Bone Joint Surg Am 85-A (2003) 1095
    • (2003) J Bone Joint Surg Am , vol.85 -A , pp. 1095
    • Orishimo, K.F.1    Claus, A.M.2    Sychterz, C.J.3
  • 4
    • 16644375334 scopus 로고    scopus 로고
    • Wear and prevalence of osteolysis in modular and non-modular acetabular cups. A match paired study at a follow up of 5 to 8 years
    • González Della Valle A., Su E., Zoppi A., et al. Wear and prevalence of osteolysis in modular and non-modular acetabular cups. A match paired study at a follow up of 5 to 8 years. J Arthroplasty 19 (2004) 972
    • (2004) J Arthroplasty , vol.19 , pp. 972
    • González Della Valle, A.1    Su, E.2    Zoppi, A.3
  • 6
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore J., Ilstrup D., and Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am 72 (1990) 518
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 518
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 7
    • 0028820598 scopus 로고
    • Measurement of polyethylene wear in metal-backed acetabular cups. I. Three-dimensional technique
    • Devane P.A., Bourne R.B., Rorabeck C.H., et al. Measurement of polyethylene wear in metal-backed acetabular cups. I. Three-dimensional technique. Clin Orthop (1995) 303
    • (1995) Clin Orthop , pp. 303
    • Devane, P.A.1    Bourne, R.B.2    Rorabeck, C.H.3
  • 8
    • 0028880699 scopus 로고
    • Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application
    • Devane P.A., Bourne R.B., Rorabeck C.H., et al. Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application. Clin Orthop (1995) 317
    • (1995) Clin Orthop , pp. 317
    • Devane, P.A.1    Bourne, R.B.2    Rorabeck, C.H.3
  • 9
    • 0031544132 scopus 로고    scopus 로고
    • Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris
    • Devane P.A., Horne J.G., Martin K., et al. Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris. J Arthroplasty 12 (1997) 256
    • (1997) J Arthroplasty , vol.12 , pp. 256
    • Devane, P.A.1    Horne, J.G.2    Martin, K.3
  • 10
    • 0030669292 scopus 로고    scopus 로고
    • Determination of polyethylene wear in total hip replacements with use of digital radiographs
    • Martell J.M., and Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am 79 (1997) 1635
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 1635
    • Martell, J.M.1    Berdia, S.2
  • 11
    • 0036788623 scopus 로고    scopus 로고
    • Heterotopic ossification after total hip arthroplasty. A critical analysis of the Brooker Classification and a simplified rating system
    • González Della Valle A., Salonia Ruzo P., Pavone V., et al. Heterotopic ossification after total hip arthroplasty. A critical analysis of the Brooker Classification and a simplified rating system. J Arthroplasty 17 (2002) 870
    • (2002) J Arthroplasty , vol.17 , pp. 870
    • González Della Valle, A.1    Salonia Ruzo, P.2    Pavone, V.3
  • 12
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307
    • (1986) Lancet , vol.1 , pp. 307
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 17144422901 scopus 로고    scopus 로고
    • Measurement of head penetration on digitalized radiographs: reproducibility and accuracy
    • Girard J., Touraine D., Soenen M., et al. Measurement of head penetration on digitalized radiographs: reproducibility and accuracy. Rev Chir Orthop Reparatrice Appar Mot 91 (2005) 137
    • (2005) Rev Chir Orthop Reparatrice Appar Mot , vol.91 , pp. 137
    • Girard, J.1    Touraine, D.2    Soenen, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.