메뉴 건너뛰기




Volumn 55, Issue 1, 2008, Pages 369-372

Cardiovascular oscillations of the carotid artery assessed by magnetoelastic skin curvature sensor

Author keywords

Cardiovascular system; Carotid artery; Physiological sensors; Skin curvature sensor

Indexed keywords

BIOSENSORS; CARDIOLOGY; MEDICAL APPLICATIONS; PATIENT TREATMENT; RESPIRATORY SYSTEM; SKIN;

EID: 37349006661     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2007.899355     Document Type: Article
Times cited : (8)

References (10)
  • 1
    • 0032586108 scopus 로고    scopus 로고
    • Noninvasive assessment of the viscoelasticity of peripheral arteries
    • Y. W. Shau, C. L. Wang, J. Y. Shieh, and T. C. Hsu, "Noninvasive assessment of the viscoelasticity of peripheral arteries," Ultrasound Med. Biol., vol. 25, no. 9, pp. 1377-1388, 1999.
    • (1999) Ultrasound Med. Biol , vol.25 , Issue.9 , pp. 1377-1388
    • Shau, Y.W.1    Wang, C.L.2    Shieh, J.Y.3    Hsu, T.C.4
  • 2
    • 0004045209 scopus 로고
    • Baltimore, MD: Williams & Wilkins Publisher
    • W. R. Milnor, Hemodynamics. Baltimore, MD: Williams & Wilkins Publisher, 1989.
    • (1989) Hemodynamics
    • Milnor, W.R.1
  • 3
    • 0033858009 scopus 로고    scopus 로고
    • Relationship between the pressure and diameter of the carotid artery in humans
    • M. Sugawara, K. Niki, H. Furuhata, S. Ohnishi, and S. Suzuki, "Relationship between the pressure and diameter of the carotid artery in humans," Heart Vessels, vol. 15, pp. 49-51, 2000.
    • (2000) Heart Vessels , vol.15 , pp. 49-51
    • Sugawara, M.1    Niki, K.2    Furuhata, H.3    Ohnishi, S.4    Suzuki, S.5
  • 6
    • 0035476262 scopus 로고    scopus 로고
    • M. Elstad, K. Toska, K. H. Chon, E. A. Raeder, and R. J. Cohen, Respiratory sinus arrhythmia: Opposite effects on systolic and mean arterial pressure in supine humans, J. Physiol., 536.1, pp. 251-259, 2001.
    • M. Elstad, K. Toska, K. H. Chon, E. A. Raeder, and R. J. Cohen, "Respiratory sinus arrhythmia: Opposite effects on systolic and mean arterial pressure in supine humans," J. Physiol., vol. 536.1, pp. 251-259, 2001.
  • 7
    • 0036066473 scopus 로고    scopus 로고
    • Clinical signs in medicine: Pulsus paradoxus
    • A. Khasnis and Y. Lokhandwala, "Clinical signs in medicine: Pulsus paradoxus," J. Postgrad. Med., vol. 48, no. 1, pp. 46-49, 2002.
    • (2002) J. Postgrad. Med , vol.48 , Issue.1 , pp. 46-49
    • Khasnis, A.1    Lokhandwala, Y.2
  • 10
    • 0037778945 scopus 로고    scopus 로고
    • Static and dynamic changes in carotid artery diameter in humans during and after strenuous exercise
    • P. Studinger, Z. Lenard, Z.Kovats, L.Kocsis, and M.Kollai, "Static and dynamic changes in carotid artery diameter in humans during and after strenuous exercise," J. Physiol., vol. 550, no. 2, pp. 575-583, 2003.
    • (2003) J. Physiol , vol.550 , Issue.2 , pp. 575-583
    • Studinger, P.1    Lenard, Z.2    Kovats, Z.3    Kocsis, L.4    Kollai, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.