메뉴 건너뛰기




Volumn 39, Issue 6, 2007, Pages 418-422

Arrosion of flexor tendons after palmar plate osteosynthesis of the distal radius: Three case reports;Arrosion der beugesehnen nach palmarer platten-osteosynthese des distalen radius: Drei fallberichte

Author keywords

Palmar plate osteosynthesis of the radius; Rupture of the deep flexor tendon

Indexed keywords

AGED; ARTICLE; BONE RADIOGRAPHY; CASE REPORT; FLEXOR TENDON; HUMAN; IMPLANT; MALE; OSTEOSYNTHESIS; RADIUS FRACTURE; VOLAR PLATE FIXATION;

EID: 37249071272     PISSN: 07221819     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2007-964880     Document Type: Article
Times cited : (6)

References (14)
  • 1
    • 0031951657 scopus 로고    scopus 로고
    • Rupture of flexor pollicis longus tendon. A complication of volar plating of the distal radius
    • Br
    • Bell JSP, Wollstein R, Citron ND: Rupture of flexor pollicis longus tendon. A complication of volar plating of the distal radius. J Bone Joint Surg [Br] 1998; 80: 225-226
    • (1998) J Bone Joint Surg , vol.80 , pp. 225-226
    • Bell, J.S.P.1    Wollstein, R.2    Citron, N.D.3
  • 3
    • 0038651175 scopus 로고    scopus 로고
    • Osteosynthesis of distal radial fractures with a volar locking screw plate system
    • Dobretz H, Kutscha-Lissberg E: Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 2003; 27: 1-6
    • (2003) Int Orthop , vol.27 , pp. 1-6
    • Dobretz, H.1    Kutscha-Lissberg, E.2
  • 4
    • 33750468969 scopus 로고    scopus 로고
    • Surgical treatment of distal radius fractures with an angle fixed bar palmar plating system: A single center study of 102 patients over a 2-year period
    • Jul 12 Epub ahead of print
    • Gruber G, Berhardt GA, Köhler G, Gruber K: Surgical treatment of distal radius fractures with an angle fixed bar palmar plating system: a single center study of 102 patients over a 2-year period. Arch Orthop Trauma Surg 2006, Jul 12 (Epub ahead of print)
    • (2006) Arch Orthop Trauma Surg
    • Gruber, G.1    Berhardt, G.A.2    Köhler, G.3    Gruber, K.4
  • 5
    • 0036241905 scopus 로고    scopus 로고
    • Palmar plating for dorsally displaced fractures of the distal radius
    • Kamano M, Honda Y, Kazuki K, Yasuda M: Palmar plating for dorsally displaced fractures of the distal radius. Clin Orthop Rel Res 2002; 397: 403-408
    • (2002) Clin Orthop Rel Res , vol.397 , pp. 403-408
    • Kamano, M.1    Honda, Y.2    Kazuki, K.3    Yasuda, M.4
  • 6
    • 27744536885 scopus 로고    scopus 로고
    • Erfahrungen und Ergebnisse mit der winkelstabilen Platte bei 603 Radiusfrakturen
    • Köck H, Bandl W-D, Chan T: Erfahrungen und Ergebnisse mit der winkelstabilen Platte bei 603 Radiusfrakturen. Handchir Mikrochir Plast Chir 2005; 37: 303-308
    • (2005) Handchir Mikrochir Plast Chir , vol.37 , pp. 303-308
    • Köck, H.1    Bandl, W.-D.2    Chan, T.3
  • 8
    • 0141955019 scopus 로고    scopus 로고
    • Surgical treatment of fractures of the distal radius with plates: A comparison of palmar and dorsal plate position
    • Letsch R, Infanger M, Schmidt J, Kock H-J: Surgical treatment of fractures of the distal radius with plates: A comparison of palmar and dorsal plate position. Arch Orthop Trauma Surg 2003; 123: 333-339
    • (2003) Arch Orthop Trauma Surg , vol.123 , pp. 333-339
    • Letsch, R.1    Infanger, M.2    Schmidt, J.3    Kock, H.-J.4
  • 9
    • 0021686893 scopus 로고
    • Tendon rupture as a complication after osteosynthesis of distal radius
    • Lugger LJ, Pechlaner S: Tendon rupture as a complication after osteosynthesis of distal radius. Unfallchirurgie 1984; 10: 266-270
    • (1984) Unfallchirurgie , vol.10 , pp. 266-270
    • Lugger, L.J.1    Pechlaner, S.2
  • 10
    • 33646840103 scopus 로고    scopus 로고
    • Current concepts in volar fixed-angle fixation of unstable distal radius fractures
    • Orbay JL, Touhami A: Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Rel Res 2006; 445: 58-67
    • (2006) Clin Orthop Rel Res , vol.445 , pp. 58-67
    • Orbay, J.L.1    Touhami, A.2
  • 11
    • 30444455922 scopus 로고    scopus 로고
    • Strecksehnenrupturen nach winkelstabiler palmarer Plattenosteosynthese distaler Radiusfrakturen
    • Roske K, Kühling J, Schmidt J: Strecksehnenrupturen nach winkelstabiler palmarer Plattenosteosynthese distaler Radiusfrakturen. Akt Traumatol 2005; 35: 335-339
    • (2005) Akt Traumatol , vol.35 , pp. 335-339
    • Roske, K.1    Kühling, J.2    Schmidt, J.3
  • 12
    • 33644649770 scopus 로고    scopus 로고
    • Functional outcome and complications after volar plating for dorsally displaced unstable fractures of the distal radius
    • Am
    • Rozental TD, Blazar PhE: Functional outcome and complications after volar plating for dorsally displaced unstable fractures of the distal radius. J Hand Surg [Am] 2006; 31: 359-365
    • (2006) J Hand Surg , vol.31 , pp. 359-365
    • Rozental, T.D.1    PhE, B.2
  • 13
    • 31544472058 scopus 로고    scopus 로고
    • Volar versus dorsal plating in the management of intra-articular distal radius fractures
    • Am
    • Ruch DS, Papadonikolakis A: Volar versus dorsal plating in the management of intra-articular distal radius fractures. J Hand Surg [Am] 2006; 31: 9-16
    • (2006) J Hand Surg , vol.31 , pp. 9-16
    • Ruch, D.S.1    Papadonikolakis, A.2
  • 14
    • 1642517070 scopus 로고    scopus 로고
    • Die winkelstabile palmare Plattenosteosynthese bei der dorsalen dislozierten distalen Radiusfraktur - Anwendung und erste klinische Erfahrungen
    • Schütz M, Kolbeck S, Spranger A, Arndt-Kolbeck M, Haas NP: Die winkelstabile palmare Plattenosteosynthese bei der dorsalen dislozierten distalen Radiusfraktur - Anwendung und erste klinische Erfahrungen. Zentralbl Chir 2003; 128: 997-1002
    • (2003) Zentralbl Chir , vol.128 , pp. 997-1002
    • Schütz, M.1    Kolbeck, S.2    Spranger, A.3    Arndt-Kolbeck, M.4    Haas, N.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.