메뉴 건너뛰기




Volumn 14, Issue 6, 2007, Pages 794-798

Endovascular repair of ascending aortic pseudoaneurysm: Technical considerations of a common carotid artery approach using the Zenith aortic cuff endograft

Author keywords

Aortic pseudoaneurysm; Ascending aorta; Common carotid artery; Cuff extenders; Endovascular repair; Stent graft

Indexed keywords

ABDOMINAL AORTA ANEURYSM; AGED; AORTA ANEURYSM; ARTERIOTOMY; ARTICLE; ARTIFICIAL EMBOLISM; ASCENDING AORTA; CAROTID ARTERY; CASE REPORT; CORONARY ARTERY BYPASS GRAFT; DYSPNEA; ENDOLEAK; FOLLOW UP; HUMAN; MALE; PRIORITY JOURNAL; PULMONARY ARTERY; STROKE; THORAX PAIN;

EID: 37049027938     PISSN: 15266028     EISSN: None     Source Type: Journal    
DOI: 10.1583/07-2165.1     Document Type: Article
Times cited : (43)

References (9)
  • 1
    • 0030866064 scopus 로고    scopus 로고
    • Aortic root surgery in Marfan syndrome: Current practice and evolving techniques
    • LeMaire SA, Coselli JS. Aortic root surgery in Marfan syndrome: current practice and evolving techniques. J Card Surg. 1997;12:137-141.
    • (1997) J Card Surg , vol.12 , pp. 137-141
    • LeMaire, S.A.1    Coselli, J.S.2
  • 2
    • 0027948241 scopus 로고
    • Successful reoperation for ascending aorta and arch aneurysm in a Jehovah's Witness
    • Coselli JS, Buket S, Van Cleve GD. Successful reoperation for ascending aorta and arch aneurysm in a Jehovah's Witness. Ann Thorac Surg. 1994;58:871-873.
    • (1994) Ann Thorac Surg , vol.58 , pp. 871-873
    • Coselli, J.S.1    Buket, S.2    Van Cleve, G.D.3
  • 3
    • 34249087671 scopus 로고    scopus 로고
    • Ashraf O, Ali SA, Tanveer-ul-Haq, et al. Endovascular setting of a leaking thoracic aortic pseudoaneurysm. J Coll Physicians Surg Pak. 2006;16:732-733.
    • Ashraf O, Ali SA, Tanveer-ul-Haq, et al. Endovascular setting of a leaking thoracic aortic pseudoaneurysm. J Coll Physicians Surg Pak. 2006;16:732-733.
  • 4
    • 0942276915 scopus 로고    scopus 로고
    • Stent-graft placement for mycotic aneurysm of the thoracic aorta: Report of a case
    • Nishimoto M, Hasegawa S, Asada K, et al. Stent-graft placement for mycotic aneurysm of the thoracic aorta: report of a case. Circ J. 2004;68:88-90.
    • (2004) Circ J , vol.68 , pp. 88-90
    • Nishimoto, M.1    Hasegawa, S.2    Asada, K.3
  • 5
    • 33751200933 scopus 로고    scopus 로고
    • Long-term results from a 12-year experience with endovascular therapy for thoracic aortic disease
    • Patel HJ, Williams DM, Upchurch GR, et al. Long-term results from a 12-year experience with endovascular therapy for thoracic aortic disease. Ann Thorac Surg. 2006;82:2147-2153.
    • (2006) Ann Thorac Surg , vol.82 , pp. 2147-2153
    • Patel, H.J.1    Williams, D.M.2    Upchurch, G.R.3
  • 6
    • 27544501364 scopus 로고    scopus 로고
    • Endovascular repair of thoracic aortic pathology with custom-made devices
    • Peterson BG, Longo GM, Matsumura JS, et al. Endovascular repair of thoracic aortic pathology with custom-made devices. Surgery. 2005; 138:598-605.
    • (2005) Surgery , vol.138 , pp. 598-605
    • Peterson, B.G.1    Longo, G.M.2    Matsumura, J.S.3
  • 7
    • 4444359974 scopus 로고    scopus 로고
    • Repair of mycotic aortic pseudoaneurysm with a stent graft using transesophageal echocardiography
    • Rayan SS, Vega JD, Shanewise JS, et al. Repair of mycotic aortic pseudoaneurysm with a stent graft using transesophageal echocardiography. J Vasc Surg. 2004;40:567-570.
    • (2004) J Vasc Surg , vol.40 , pp. 567-570
    • Rayan, S.S.1    Vega, J.D.2    Shanewise, J.S.3
  • 8
    • 16144367754 scopus 로고    scopus 로고
    • A safe, simple alternative for pressure reduction during aortic endograft deployment [Commentary]
    • Diethrich EB. A safe, simple alternative for pressure reduction during aortic endograft deployment [Commentary]. J Endovasc Surg. 1996;3:275.
    • (1996) J Endovasc Surg , vol.3 , pp. 275
    • Diethrich, E.B.1
  • 9
    • 0031711791 scopus 로고    scopus 로고
    • Adenosine-induced transient cardiac arrest for placement of endovascular stent-grafts in the thoracic aorta
    • Weigand MA, Motsch J, Bardenheuer HJ. Adenosine-induced transient cardiac arrest for placement of endovascular stent-grafts in the thoracic aorta. Anesthesiology. 1998;89:1037-108.
    • (1998) Anesthesiology , vol.89 , pp. 1037-1108
    • Weigand, M.A.1    Motsch, J.2    Bardenheuer, H.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.