메뉴 건너뛰기




Volumn 34, Issue 1, 2008, Pages 114-122

Ultrasonic Observation of Blood Disturbance in a Stenosed Tube: Effects of Flow Acceleration and Turbulence Downstream

Author keywords

"Black hole" phenomenon; Acceleration; Eccentric stenosis; Pulsatile flow; Red blood cell aggregation; Shear rate; Turbulence; Ultrasound echogenicity

Indexed keywords

BLOOD; PULSATILE FLOW; SHEAR DEFORMATION; TURBULENCE MODELS; ULTRASONICS;

EID: 37049025573     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2007.07.009     Document Type: Article
Times cited : (18)

References (31)
  • 1
    • 0032144713 scopus 로고    scopus 로고
    • An experimental investigation of pulsatile flow through a smooth constriction
    • Ahmed S. An experimental investigation of pulsatile flow through a smooth constriction. Exper Therm Fluid Sci 17 (1998) 309-318
    • (1998) Exper Therm Fluid Sci , vol.17 , pp. 309-318
    • Ahmed, S.1
  • 2
    • 0030106988 scopus 로고    scopus 로고
    • Effect of the insonification angle on the Doppler backscattered power under red blood cell aggregation conditions
    • Allard L., Cloutier G., and Durand L.-G. Effect of the insonification angle on the Doppler backscattered power under red blood cell aggregation conditions. IEEE Trans Ultrason Ferroelectr Freq Cont 43 (1996) 211-219
    • (1996) IEEE Trans Ultrason Ferroelectr Freq Cont , vol.43 , pp. 211-219
    • Allard, L.1    Cloutier, G.2    Durand, L.-G.3
  • 3
    • 0033158259 scopus 로고    scopus 로고
    • Histopathology of thrombotic vascular diseases
    • Asada Y., and Sumiyoshi A. Histopathology of thrombotic vascular diseases. Nippon Rinsho 57 (1999) 1555-1560
    • (1999) Nippon Rinsho , vol.57 , pp. 1555-1560
    • Asada, Y.1    Sumiyoshi, A.2
  • 4
    • 0028829046 scopus 로고
    • On a fractal packing approach for understanding ultrasonic backscattering from blood
    • Bascom P.A.J., and Cobbold R.S.C. On a fractal packing approach for understanding ultrasonic backscattering from blood. J Acoust Soc Am 98 (1995) 3040-3049
    • (1995) J Acoust Soc Am , vol.98 , pp. 3040-3049
    • Bascom, P.A.J.1    Cobbold, R.S.C.2
  • 5
    • 0031048867 scopus 로고    scopus 로고
    • Relation of the flow field distal to a moderate stenosis to the Doppler power
    • Bascom P.A.J., Johnston K.W., Cobbold R.S.C., and Ojha M. Relation of the flow field distal to a moderate stenosis to the Doppler power. Ultrasound Med Biol 23 (1997) 25-39
    • (1997) Ultrasound Med Biol , vol.23 , pp. 25-39
    • Bascom, P.A.J.1    Johnston, K.W.2    Cobbold, R.S.C.3    Ojha, M.4
  • 7
    • 0035019802 scopus 로고    scopus 로고
    • The "black hole" phenomenon in ultrasonic backscattering measurement under pulsatile flow with porcine whole blood in a rigid tube
    • Cao P.-J., Paeng D.-G., and Shung K.K. The "black hole" phenomenon in ultrasonic backscattering measurement under pulsatile flow with porcine whole blood in a rigid tube. Biorheology 38 (2001) 15-26
    • (2001) Biorheology , vol.38 , pp. 15-26
    • Cao, P.-J.1    Paeng, D.-G.2    Shung, K.K.3
  • 8
    • 0028852825 scopus 로고
    • Changes in ultrasonic Doppler backscattered power downstream of concentric and eccentric stenosis under pulsatile flow
    • Cloutier G., Allard L., and Durand L.-G. Changes in ultrasonic Doppler backscattered power downstream of concentric and eccentric stenosis under pulsatile flow. Ultrasound Med Biol 21 (1995) 59-70
    • (1995) Ultrasound Med Biol , vol.21 , pp. 59-70
    • Cloutier, G.1    Allard, L.2    Durand, L.-G.3
  • 9
    • 0030221281 scopus 로고    scopus 로고
    • Characterization of blood flow turbulence with pulsed-wave and power Doppler ultrasound imaging
    • Cloutier G., Allard L., and Durand L.-G. Characterization of blood flow turbulence with pulsed-wave and power Doppler ultrasound imaging. J Biomech Eng 118 (1996) 318-325
    • (1996) J Biomech Eng , vol.118 , pp. 318-325
    • Cloutier, G.1    Allard, L.2    Durand, L.-G.3
  • 10
    • 0034503421 scopus 로고    scopus 로고
    • Assessment of arterial stenosis in a flow model with power Doppler angiography: Accuracy and observations on blood echogenicity
    • Cloutier G., Qin Z., Garcia D., Soulez G., Oliva V., and Durand L.-G. Assessment of arterial stenosis in a flow model with power Doppler angiography: Accuracy and observations on blood echogenicity. Ultrasound Med Biol 26 (2000) 1489-1501
    • (2000) Ultrasound Med Biol , vol.26 , pp. 1489-1501
    • Cloutier, G.1    Qin, Z.2    Garcia, D.3    Soulez, G.4    Oliva, V.5    Durand, L.-G.6
  • 13
    • 0021966255 scopus 로고
    • Pulsatile flow and atherosclerosis in the human carotid bifurcation
    • Ku D.N., Giddens D.P., and Downing J.M. Pulsatile flow and atherosclerosis in the human carotid bifurcation. Arteriosclerosis 5 (1985) 293-302
    • (1985) Arteriosclerosis , vol.5 , pp. 293-302
    • Ku, D.N.1    Giddens, D.P.2    Downing, J.M.3
  • 14
    • 0031433421 scopus 로고    scopus 로고
    • Simulation of red blood cell aggregation in shear flow
    • Lim B., Bascom P.A.J., and Cobbold R.S.C. Simulation of red blood cell aggregation in shear flow. Biorheology 34 (1997) 423-441
    • (1997) Biorheology , vol.34 , pp. 423-441
    • Lim, B.1    Bascom, P.A.J.2    Cobbold, R.S.C.3
  • 15
    • 0023406830 scopus 로고
    • Inversion of ultrasonic scattering data for red blood cell suspensions under different flow conditions
    • Lucas R.J., and Twersky V. Inversion of ultrasonic scattering data for red blood cell suspensions under different flow conditions. J Acoust Soc Am 82 (1987) 794-799
    • (1987) J Acoust Soc Am , vol.82 , pp. 794-799
    • Lucas, R.J.1    Twersky, V.2
  • 16
    • 0036373898 scopus 로고    scopus 로고
    • Laminar-to-turbulent transition in pulsatile flow through a stenosis
    • Mallinger F., and Drikakis D. Laminar-to-turbulent transition in pulsatile flow through a stenosis. Biorheology 39 (2002) 437-441
    • (2002) Biorheology , vol.39 , pp. 437-441
    • Mallinger, F.1    Drikakis, D.2
  • 17
    • 0034824006 scopus 로고    scopus 로고
    • Application of large-eddy simulation to the study of pulsatile flow in a modeled arterial stenosis
    • Mittal R., Simmons S.P., and Udaykumar H.S. Application of large-eddy simulation to the study of pulsatile flow in a modeled arterial stenosis. ASME J Biomech Eng 123 (2001) 325-331
    • (2001) ASME J Biomech Eng , vol.123 , pp. 325-331
    • Mittal, R.1    Simmons, S.P.2    Udaykumar, H.S.3
  • 18
    • 0026870052 scopus 로고
    • An unified approach to modeling the backscattered Doppler ultrasound form blood
    • Mo L.Y.L., and Cobbold R.S.C. An unified approach to modeling the backscattered Doppler ultrasound form blood. IEEE Trans Biomed Eng 39 (1992) 450-461
    • (1992) IEEE Trans Biomed Eng , vol.39 , pp. 450-461
    • Mo, L.Y.L.1    Cobbold, R.S.C.2
  • 19
    • 8644285526 scopus 로고    scopus 로고
    • Ultrasonic backscatter response to blood flow disturbance by a severe eccentric stenosis
    • Paeng D.-G., Cao P.-J., Choi M.J., and Shung K.K. Ultrasonic backscatter response to blood flow disturbance by a severe eccentric stenosis. Key Eng Mater 273 (2004) 2036-2041
    • (2004) Key Eng Mater , vol.273 , pp. 2036-2041
    • Paeng, D.-G.1    Cao, P.-J.2    Choi, M.J.3    Shung, K.K.4
  • 20
    • 0034814324 scopus 로고    scopus 로고
    • Doppler power variation from porcine blood under steady and pulsatile flow
    • Paeng D.-G., Cao P.-J., and Shung K.K. Doppler power variation from porcine blood under steady and pulsatile flow. Ultrasound Med Biol 27 (2001) 1245-1254
    • (2001) Ultrasound Med Biol , vol.27 , pp. 1245-1254
    • Paeng, D.-G.1    Cao, P.-J.2    Shung, K.K.3
  • 21
    • 1042275656 scopus 로고    scopus 로고
    • Echogenicity variations from porcine blood I: The "bright collapsing ring" under pulsatile flow
    • Paeng D.-G., Chiao R.Y., and Shung K.K. Echogenicity variations from porcine blood I: The "bright collapsing ring" under pulsatile flow. Ultrasound Med Biol 30 (2004) 45-55
    • (2004) Ultrasound Med Biol , vol.30 , pp. 45-55
    • Paeng, D.-G.1    Chiao, R.Y.2    Shung, K.K.3
  • 22
    • 3042521348 scopus 로고    scopus 로고
    • Echogenicity variations from porcine blood II: The "bright ring" under oscillatory flow
    • Paeng D.-G., Chiao R.Y., and Shung K.K. Echogenicity variations from porcine blood II: The "bright ring" under oscillatory flow. Ultrasound Med Biol 30 (2004) 815-825
    • (2004) Ultrasound Med Biol , vol.30 , pp. 815-825
    • Paeng, D.-G.1    Chiao, R.Y.2    Shung, K.K.3
  • 23
    • 4143102628 scopus 로고    scopus 로고
    • In vivo observation of blood echogenicity variation during a cardiac cycle on human carotid arteries
    • Paeng D.-G., Kim B.S., Choi M.J., Chiao R.Y., and Shung K.K. In vivo observation of blood echogenicity variation during a cardiac cycle on human carotid arteries. Proc IEEE Ultrason Symp 1 (2003) 847-850
    • (2003) Proc IEEE Ultrason Symp , vol.1 , pp. 847-850
    • Paeng, D.-G.1    Kim, B.S.2    Choi, M.J.3    Chiao, R.Y.4    Shung, K.K.5
  • 24
    • 0028346767 scopus 로고
    • Aggregation effects in whole blood: Influence of time and shear rate measured using ultrasound
    • Shehada R.E.N., Cobbold R.S.C., and Mo L.Y.L. Aggregation effects in whole blood: Influence of time and shear rate measured using ultrasound. Biorheology 1 (1994) 115-135
    • (1994) Biorheology , vol.1 , pp. 115-135
    • Shehada, R.E.N.1    Cobbold, R.S.C.2    Mo, L.Y.L.3
  • 25
    • 0026870058 scopus 로고
    • The effects of hematocrit, shear rate and turbulence on the ultrasonic Doppler spectrum from blood
    • Shung K.K., Cloutier G., and Lim C.C. The effects of hematocrit, shear rate and turbulence on the ultrasonic Doppler spectrum from blood. IEEE Trans Biomed Eng 39 (1992) 462-469
    • (1992) IEEE Trans Biomed Eng , vol.39 , pp. 462-469
    • Shung, K.K.1    Cloutier, G.2    Lim, C.C.3
  • 26
    • 0020509838 scopus 로고
    • Red cell aggregation as a cause of blood-flow echogenicity
    • Sigel B., Machi J., Beitler J.C., and Justin J.R. Red cell aggregation as a cause of blood-flow echogenicity. Radiology 148 (1983) 799-802
    • (1983) Radiology , vol.148 , pp. 799-802
    • Sigel, B.1    Machi, J.2    Beitler, J.C.3    Justin, J.R.4
  • 27
    • 0016303196 scopus 로고
    • Measured turbulence and its effect on thrombus formation
    • Stein P.D., and Sabbah H.N. Measured turbulence and its effect on thrombus formation. Circ Res 35 (1974) 608-614
    • (1974) Circ Res , vol.35 , pp. 608-614
    • Stein, P.D.1    Sabbah, H.N.2
  • 28
    • 55249091059 scopus 로고
    • Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known
    • Womersley J.R. Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known. J Physiol 127 (1955) 553-563
    • (1955) J Physiol , vol.127 , pp. 553-563
    • Womersley, J.R.1
  • 29
    • 0013963958 scopus 로고
    • Laminar-turbulent transition process in pulsatile flow
    • Yellin E.L. Laminar-turbulent transition process in pulsatile flow. Circ Res 19 (1966) 791-804
    • (1966) Circ Res , vol.19 , pp. 791-804
    • Yellin, E.L.1
  • 30
    • 0023822405 scopus 로고
    • Ultrasonic backscatter from flowing whole blood I: Dependence on shear rate and hematocrit
    • Yuan Y.W., and Shung K.K. Ultrasonic backscatter from flowing whole blood I: Dependence on shear rate and hematocrit. J Acoust Soc Am 84 (1988) 52-58
    • (1988) J Acoust Soc Am , vol.84 , pp. 52-58
    • Yuan, Y.W.1    Shung, K.K.2
  • 31
    • 0024370085 scopus 로고
    • Echogenicity of whole blood
    • Yuan Y.W., and Shung K.K. Echogenicity of whole blood. J Ultrasound Med 8 (1989) 425-434
    • (1989) J Ultrasound Med , vol.8 , pp. 425-434
    • Yuan, Y.W.1    Shung, K.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.