메뉴 건너뛰기




Volumn 34, Issue 1, 2008, Pages 155-159

In-Vitro Comparison of Time-Domain, Frequency-Domain and Wavelet Ultrasound Parameters in Diagnostics of Cartilage Degeneration

Author keywords

Articular cartilage; Osteoarthrosis; Ultrasound; Wavelet transform

Indexed keywords

COMPUTER AIDED DIAGNOSIS; DISEASES; FREQUENCY DOMAIN ANALYSIS; MEDICAL IMAGING; SURFACE ROUGHNESS; WAVELET TRANSFORMS;

EID: 37049011404     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2007.06.028     Document Type: Article
Times cited : (23)

References (19)
  • 3
    • 0029198305 scopus 로고
    • Degenerative joint disease
    • Buckwalter J.A., and Martin J. Degenerative joint disease. Clin Symp 47 (1995) 1-32
    • (1995) Clin Symp , vol.47 , pp. 1-32
    • Buckwalter, J.A.1    Martin, J.2
  • 4
    • 0032033723 scopus 로고    scopus 로고
    • Evaluation of acoustical parameter sensitivity to age-related and osteoarthritic changes in articular cartilage using 50-MHz ultrasound
    • Chérin E., Saïed A., Laugier P., Netter P., and Berger G. Evaluation of acoustical parameter sensitivity to age-related and osteoarthritic changes in articular cartilage using 50-MHz ultrasound. Ultrasound Med Biol 24 (1998) 341-354
    • (1998) Ultrasound Med Biol , vol.24 , pp. 341-354
    • Chérin, E.1    Saïed, A.2    Laugier, P.3    Netter, P.4    Berger, G.5
  • 5
    • 0030987217 scopus 로고    scopus 로고
    • Ultrasonic characterization of in vitro osteoarthritic articular cartilage with validation by confocal microscopy
    • Chiang E.H., Laing T.J., Meyer C.R., Boes J.L., Rubin J.M., and Adler R.S. Ultrasonic characterization of in vitro osteoarthritic articular cartilage with validation by confocal microscopy. Ultrasound Med Biol 23 (1997) 205-213
    • (1997) Ultrasound Med Biol , vol.23 , pp. 205-213
    • Chiang, E.H.1    Laing, T.J.2    Meyer, C.R.3    Boes, J.L.4    Rubin, J.M.5    Adler, R.S.6
  • 6
    • 0034094969 scopus 로고    scopus 로고
    • Articular cartilage defects: in vitro evaluation of accuracy and interobserver reliability for detection and grading with US
    • Disler D.G., Raymond E., May D.A., Wayne J.S., and McCauley T.R. Articular cartilage defects: in vitro evaluation of accuracy and interobserver reliability for detection and grading with US. Radiology 215 (2000) 846-851
    • (2000) Radiology , vol.215 , pp. 846-851
    • Disler, D.G.1    Raymond, E.2    May, D.A.3    Wayne, J.S.4    McCauley, T.R.5
  • 7
    • 0037710681 scopus 로고    scopus 로고
    • Measurement of the mechanical condition of articular cartilage with an ultrasonic probe: Quantitative evaluation using wavelet transformation
    • Hattori K., Mori K., Habata T., Takakura Y., and Ikeuchi K. Measurement of the mechanical condition of articular cartilage with an ultrasonic probe: Quantitative evaluation using wavelet transformation. Clin Biomech 18 (2003) 553-557
    • (2003) Clin Biomech , vol.18 , pp. 553-557
    • Hattori, K.1    Mori, K.2    Habata, T.3    Takakura, Y.4    Ikeuchi, K.5
  • 9
    • 0035656819 scopus 로고    scopus 로고
    • High frequency acoustic parameters of human and bovine articular cartilage following experimentally-induced matrix degradation
    • Joiner G.A., Bogoch E.R., Pritzker K.P., Buschmann M.D., Chevrier A., and Foster F.S. High frequency acoustic parameters of human and bovine articular cartilage following experimentally-induced matrix degradation. Ultrason Imaging 23 (2001) 106-116
    • (2001) Ultrason Imaging , vol.23 , pp. 106-116
    • Joiner, G.A.1    Bogoch, E.R.2    Pritzker, K.P.3    Buschmann, M.D.4    Chevrier, A.5    Foster, F.S.6
  • 11
    • 0015046195 scopus 로고
    • Biochemical and metabolic abnormalities in articular cartilage from osteo-arthritic human hips. II. Correlation of morphology with biochemical and metabolic data
    • Mankin H.J., Dorfman H., Lippiello L., and Zarins A. Biochemical and metabolic abnormalities in articular cartilage from osteo-arthritic human hips. II. Correlation of morphology with biochemical and metabolic data. J Bone Joint Surg 53 (1971) 523-537
    • (1971) J Bone Joint Surg , vol.53 , pp. 523-537
    • Mankin, H.J.1    Dorfman, H.2    Lippiello, L.3    Zarins, A.4
  • 16
    • 33749634666 scopus 로고    scopus 로고
    • Quantitative ultrasound imaging detects degenerative changes in articular cartilage surface and subchondral bone
    • Saarakkala S., Laasanen M.S., Jurvelin J.S., and Töyräs J. Quantitative ultrasound imaging detects degenerative changes in articular cartilage surface and subchondral bone. Phys Med Biol 51 (2006) 5333-5346
    • (2006) Phys Med Biol , vol.51 , pp. 5333-5346
    • Saarakkala, S.1    Laasanen, M.S.2    Jurvelin, J.S.3    Töyräs, J.4
  • 17
    • 1842372718 scopus 로고    scopus 로고
    • Assessment of articular cartilage and subchondral bone: Subtle and progressive changes in experimental osteoarthritis using 50 MHz echography in vitro
    • Saïed A., Chérin E., Gaucher H., Laugier P., Gillet P., Floquet J., Netter P., and Berger G. Assessment of articular cartilage and subchondral bone: Subtle and progressive changes in experimental osteoarthritis using 50 MHz echography in vitro. J Bone Miner Res 12 (1997) 1378-1386
    • (1997) J Bone Miner Res , vol.12 , pp. 1378-1386
    • Saïed, A.1    Chérin, E.2    Gaucher, H.3    Laugier, P.4    Gillet, P.5    Floquet, J.6    Netter, P.7    Berger, G.8
  • 18
    • 0344241018 scopus 로고    scopus 로고
    • Characterization of enzymatically induced degradation of articular cartilage using high frequency ultrasound
    • Töyräs J., Rieppo J., Nieminen M.T., Helminen H.J., and Jurvelin J.S. Characterization of enzymatically induced degradation of articular cartilage using high frequency ultrasound. Phys Med Biol 44 (1999) 2723-2733
    • (1999) Phys Med Biol , vol.44 , pp. 2723-2733
    • Töyräs, J.1    Rieppo, J.2    Nieminen, M.T.3    Helminen, H.J.4    Jurvelin, J.S.5
  • 19
    • 0035263386 scopus 로고    scopus 로고
    • The influence of roughness, angle, range, and transducer type on the echo signal from planar interface
    • Wilhjelm J.E., Pedersen P.C., and Jacobsen S.M. The influence of roughness, angle, range, and transducer type on the echo signal from planar interface. IEEE Trans Ultrason Ferroelectr Freq Control 48 (2001) 511-521
    • (2001) IEEE Trans Ultrason Ferroelectr Freq Control , vol.48 , pp. 511-521
    • Wilhjelm, J.E.1    Pedersen, P.C.2    Jacobsen, S.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.