메뉴 건너뛰기




Volumn 38, Issue 1, 2008, Pages 31-41

Applicability of adaptive noise cancellation to fetal heart rate detection using photoplethysmography

Author keywords

Adaptive signal processing; Fetal heart rate; Monitoring; Optical model; Photoplethysmogram

Indexed keywords

ADAPTIVE SYSTEMS; BIOELECTRIC POTENTIALS; FETAL MONITORING; SIGNAL TO NOISE RATIO; TISSUE;

EID: 37049009504     PISSN: 00104825     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.compbiomed.2007.06.007     Document Type: Article
Times cited : (26)

References (29)
  • 1
    • 0346690209 scopus 로고    scopus 로고
    • Maternal self-administered fetal heart rate monitoring and transmission from home in high-risk pregnancies
    • Kerner R., Yogev Y., Belkin A., Ben-Haroush A., Zeevi B., and Hod M. Maternal self-administered fetal heart rate monitoring and transmission from home in high-risk pregnancies. Int. J. Gynecol. Obstetr. 84 1 (2004) 33-39
    • (2004) Int. J. Gynecol. Obstetr. , vol.84 , Issue.1 , pp. 33-39
    • Kerner, R.1    Yogev, Y.2    Belkin, A.3    Ben-Haroush, A.4    Zeevi, B.5    Hod, M.6
  • 3
    • 0029702120 scopus 로고    scopus 로고
    • B. Karlsson, D. Pourcelot, L. Pourcelot, M. Berson, Miniature sensor for Doppler ultrasound fetal heart rate monitoring. Increased patient comfort and ergonomy in use, Instrumentation and Measurement Technology Conference, IMTC-96 Conference Proceedings. Quality Measurements: The Indispensable Bridge between Theory and Reality, vol. 2, IEEE, New York, 1996, pp. 1336-1338.
  • 4
    • 0032124062 scopus 로고    scopus 로고
    • Distance of fetal movement measured using the analytical signal derived from non-directional Doppler sound
    • Karlsson B., Pourcelot D., Helgason T., Pourcelot L., and Berson M. Distance of fetal movement measured using the analytical signal derived from non-directional Doppler sound. Med. Eng. Phys. J. (1998) 325-331
    • (1998) Med. Eng. Phys. J. , pp. 325-331
    • Karlsson, B.1    Pourcelot, D.2    Helgason, T.3    Pourcelot, L.4    Berson, M.5
  • 5
    • 0034057073 scopus 로고    scopus 로고
    • Effects of fetal and maternal breathing on the ultrasonic Doppler signal due to fetal heart movement
    • Karlsson B., Berson M., Helgason T., Geirsson R.T., and Pourcelot L. Effects of fetal and maternal breathing on the ultrasonic Doppler signal due to fetal heart movement. Eur. J. Ultrasound (2000) 47-52
    • (2000) Eur. J. Ultrasound , pp. 47-52
    • Karlsson, B.1    Berson, M.2    Helgason, T.3    Geirsson, R.T.4    Pourcelot, L.5
  • 6
    • 37049017416 scopus 로고    scopus 로고
    • S.M. Szildgyi, L. Szildgyi, L. David, Fetal Electrocardiogram monitoring via an intrauterine catheter, Engineering in Medicine and Biology Society, Proceedings of the 19th Annual International Conference of the IEEE, vol. 1, 1997, pp. 272-274.
  • 7
    • 32544452223 scopus 로고    scopus 로고
    • Extraction of temporally correlated sources with its application to non-invasive fetal electrocardiogram extraction
    • Zhang Z.L., and Yi Z. Extraction of temporally correlated sources with its application to non-invasive fetal electrocardiogram extraction. Neurocomputing 69 7-9 (2006) 894-899
    • (2006) Neurocomputing , vol.69 , Issue.7-9 , pp. 894-899
    • Zhang, Z.L.1    Yi, Z.2
  • 8
    • 0002015916 scopus 로고
    • Development of the magnetocardiograms from the 13th week of gestation onward
    • Dunajski Z., and Peters M. Development of the magnetocardiograms from the 13th week of gestation onward. J. Biomagnetism: Fundamental Res. Clin. Appl. (1995) 340-341
    • (1995) J. Biomagnetism: Fundamental Res. Clin. Appl. , pp. 340-341
    • Dunajski, Z.1    Peters, M.2
  • 9
    • 0028134947 scopus 로고    scopus 로고
    • A. Quinn, A. Weir, U. Shahani, R. Bain, P. Maas, G. Donaldson, Antenatal fetal magnetocardiography: a new method for fetal surveillance? Br. J. Obstetr. Gynecol. (1994) 866-870.
  • 10
    • 0034164351 scopus 로고    scopus 로고
    • N. Ramanujam, G. Vishnoi, A.H. Hielscher, M.E. Rode, I. Forouzan, B. Chance, Photon migration through the fetal head in utero using continuous wave, near infrared spectroscopy: clinical and experimental model studies, J. Biomed. Opti. (2000) 163-172.
  • 11
    • 0034287394 scopus 로고    scopus 로고
    • Trans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry
    • Zourabian A., Chance B., Ramanujam N., Martha R., and David A.B. Trans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry. J. Biomed. Opt. (2000) 391-405
    • (2000) J. Biomed. Opt. , pp. 391-405
    • Zourabian, A.1    Chance, B.2    Ramanujam, N.3    Martha, R.4    David, A.B.5
  • 12
    • 0034864722 scopus 로고    scopus 로고
    • A. Zourabian, A.B. David, Theoretical considerations to optimize trans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry, Optical Tomography and Spectroscopy of Tissue IV, Proc. SPIE 4250 (2001) 82-92.
  • 14
    • 0348207855 scopus 로고    scopus 로고
    • Fundamental study of reflection pulse oximetry
    • Matsushita K., Aoki K., Kakuta N., and Yamada Y. Fundamental study of reflection pulse oximetry. Opt. Rev. 10 5 (2003) 482-487
    • (2003) Opt. Rev. , vol.10 , Issue.5 , pp. 482-487
    • Matsushita, K.1    Aoki, K.2    Kakuta, N.3    Yamada, Y.4
  • 17
    • 37049031525 scopus 로고    scopus 로고
    • D.S. Richards, S.G. Allen, M.A. White, D.R. Perez, Umbilical vessels: visualization, Department of Obstetrics and Gynecology, University of Florida College of Medicine, Available online from: 〈http://www.thefetus.net/〉.
  • 18
    • 15344348833 scopus 로고    scopus 로고
    • The pulse in reflectance pulse oximetry: modelling and experiment studies
    • Reuss J.L., and Siker D. The pulse in reflectance pulse oximetry: modelling and experiment studies. J. Clin. Monitoring Comput. (2004) 289-299
    • (2004) J. Clin. Monitoring Comput. , pp. 289-299
    • Reuss, J.L.1    Siker, D.2
  • 19
    • 0028448824 scopus 로고
    • Optical oximetry sensor for whole blood and tissue
    • Takatani S. Optical oximetry sensor for whole blood and tissue. IEEE Eng. Med. Biol. (1994) 347-357
    • (1994) IEEE Eng. Med. Biol. , pp. 347-357
    • Takatani, S.1
  • 21
    • 0030199595 scopus 로고    scopus 로고
    • Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering technique
    • Nakajima K., Tamura T., and Miike H. Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering technique. Med. Eng. Phys. 18 5 (1996) 365-372
    • (1996) Med. Eng. Phys. , vol.18 , Issue.5 , pp. 365-372
    • Nakajima, K.1    Tamura, T.2    Miike, H.3
  • 22
    • 0028746680 scopus 로고    scopus 로고
    • D. Barschdorff, W. Zhang, Respiratory rhythm detection with photoplethysmographic methods. Engineering in Medicine and Biology Society. Engineering advances: new opportunities for biomedical engineers, Proceedings of the 16th Annual International Conference of the IEEE, 1994, pp. 912-913.
  • 23
    • 0034313775 scopus 로고    scopus 로고
    • Variability of photoplethysmography peripheral pulse measurements at the ears, thumbs and toes
    • Allen J., and Murray A. Variability of photoplethysmography peripheral pulse measurements at the ears, thumbs and toes. IEEE Proc. Sci. Technol. 147 6 (2000) 403-407
    • (2000) IEEE Proc. Sci. Technol. , vol.147 , Issue.6 , pp. 403-407
    • Allen, J.1    Murray, A.2
  • 24
  • 26
    • 0000743021 scopus 로고    scopus 로고
    • Design and evaluation of a continues-wave diffuse optical tomography system
    • Siegel A.M., Marota J.J.A., and Boas D.A. Design and evaluation of a continues-wave diffuse optical tomography system. Opt. Express 4 8 (1999) 287-297
    • (1999) Opt. Express , vol.4 , Issue.8 , pp. 287-297
    • Siegel, A.M.1    Marota, J.J.A.2    Boas, D.A.3
  • 27
    • 0036790009 scopus 로고    scopus 로고
    • Non-invasive neuroimaging using near-infrared light
    • Strangman G., Boas D.A., and Sutton J.P. Non-invasive neuroimaging using near-infrared light. Soc. Biol. Psychiatry 52 (2002) 679-693
    • (2002) Soc. Biol. Psychiatry , vol.52 , pp. 679-693
    • Strangman, G.1    Boas, D.A.2    Sutton, J.P.3
  • 28
    • 12844281334 scopus 로고    scopus 로고
    • Transabdominal fetal pulse oximetry using near-infrared spectroscopy
    • Vintzileos A.M., Nioka S., Lake M., et al. Transabdominal fetal pulse oximetry using near-infrared spectroscopy. Am. J. Obstetr. Gynaecol. 192 (2005) 129-133
    • (2005) Am. J. Obstetr. Gynaecol. , vol.192 , pp. 129-133
    • Vintzileos, A.M.1    Nioka, S.2    Lake, M.3
  • 29
    • 15844367336 scopus 로고    scopus 로고
    • Coded excitation for diagnostic ultrasound: a system developer's perspective
    • Chiao R.Y., and Hao X. Coded excitation for diagnostic ultrasound: a system developer's perspective. IEEE Trans. Ultrasonics Ferroelectrics Frequency Control 52 2 (2005) 160-170
    • (2005) IEEE Trans. Ultrasonics Ferroelectrics Frequency Control , vol.52 , Issue.2 , pp. 160-170
    • Chiao, R.Y.1    Hao, X.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.