Volumn 54, Issue 10, 2007, Pages 2091-2101

High speed imaging of bubble clouds generated in pulsed ultrasound cavitational therapy - Histotripsy

Author keywords

[No Author keywords available]

Indexed keywords

BULK TISSUE; HIGH SPEED IMAGING; HISTOTRIPSY;

EID: 37049004935     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2007.504     Document Type: Article
Times cited : (102)

References (38)
  • 1
    • 0014896122 scopus 로고
    • Threshold ultrasound dosages for structural changes in the mammalian brain
    • F. J. Fry, G. Kossoff, R. C. Eggleton, and F. Dunn, "Threshold ultrasound dosages for structural changes in the mammalian brain," J. Acoust. Soc. Amer., vol. 48, pp. 1413-1417, 1970.
    • (1970) J. Acoust. Soc. Amer , vol.48 , pp. 1413-1417
    • Fry, F.J.1    Kossoff, G.2    Eggleton, R.C.3    Dunn, F.4
  • 2
    • 0015083434 scopus 로고
    • Ultrasonic threshold dosages for the mammalian central nervous system
    • F. Dunn and F. J. Fry, "Ultrasonic threshold dosages for the mammalian central nervous system," IEEE Trans. Biomed. Eng., vol. 18, pp. 253-256, 1971.
    • (1971) IEEE Trans. Biomed. Eng , vol.18 , pp. 253-256
    • Dunn, F.1    Fry, F.J.2
  • 3
  • 4
    • 0022688729 scopus 로고
    • Evidence for acoustic cavitation in vivo: Threshold for bubble formation with 0.75-MHz continuous-wave and pulsed beam
    • G. R. ter Haar, S. Daniels, and K. Morton, "Evidence for acoustic cavitation in vivo: Threshold for bubble formation with 0.75-MHz continuous-wave and pulsed beam," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 33, pp. 162-164, 1986.
    • (1986) IEEE Trans. Ultrason., Ferroelect., Freq. Contr , vol.33 , pp. 162-164
    • ter Haar, G.R.1    Daniels, S.2    Morton, K.3
  • 5
    • 0026090542 scopus 로고
    • Threshold for thermally significant cavitation in dog's thigh muscle in vivo
    • K. Hynynen, "Threshold for thermally significant cavitation in dog's thigh muscle in vivo," Ultrasound Med. Biol., vol. 17, pp. 157-169, 1991.
    • (1991) Ultrasound Med. Biol , vol.17 , pp. 157-169
    • Hynynen, K.1
  • 6
    • 0026452503 scopus 로고
    • In vivo effects of high-intensity ultrasound on prostatic adenocarcinoma Dunning R3327
    • J. Y. Chapelon, J. Margonari, F. Vernier, F. Gorry, R. Ecochard, and A. Gelet, "In vivo effects of high-intensity ultrasound on prostatic adenocarcinoma Dunning R3327," Cancer Res., vol. 52, pp. 6353-6357, 1992.
    • (1992) Cancer Res , vol.52 , pp. 6353-6357
    • Chapelon, J.Y.1    Margonari, J.2    Vernier, F.3    Gorry, F.4    Ecochard, R.5    Gelet, A.6
  • 7
    • 0032169282 scopus 로고    scopus 로고
    • The feasibility of using focused ultrasound for transmyocardial revascularization
    • N. B. Smith and K. Hynynen, "The feasibility of using focused ultrasound for transmyocardial revascularization," Ultrasound Med. Biol., vol. 24, pp. 1045-1054, 1998.
    • (1998) Ultrasound Med. Biol , vol.24 , pp. 1045-1054
    • Smith, N.B.1    Hynynen, K.2
  • 9
    • 8844226733 scopus 로고    scopus 로고
    • Sonodynamic treatment of murine tumor through second-harmonic superimposition
    • K. Sasaki, K. Kawabata, N. Yumita, and S. Umemura, "Sonodynamic treatment of murine tumor through second-harmonic superimposition," Ultrasound Med. Biol., vol. 30, pp. 1233-1238, 2004.
    • (2004) Ultrasound Med. Biol , vol.30 , pp. 1233-1238
    • Sasaki, K.1    Kawabata, K.2    Yumita, N.3    Umemura, S.4
  • 10
    • 0026047860 scopus 로고
    • Treatment of the Dunning prostate rat tumor R3327-AT1 with pulsed high energy ultrasound shock waves (PHEUS): Growth delay and histomorphologic changes
    • J. Debus, P. Peschke, E. W. Hahn, W. J. Lorenz, A. Lorenz, H. Ifflaender, H. J. Zabel, G. Van Kaick, and M. Pfeiler, "Treatment of the Dunning prostate rat tumor R3327-AT1 with pulsed high energy ultrasound shock waves (PHEUS): Growth delay and histomorphologic changes," J. Urol., vol. 146, pp. 1143-1146, 1991.
    • (1991) J. Urol , vol.146 , pp. 1143-1146
    • Debus, J.1    Peschke, P.2    Hahn, E.W.3    Lorenz, W.J.4    Lorenz, A.5    Ifflaender, H.6    Zabel, H.J.7    Van Kaick, G.8    Pfeiler, M.9
  • 11
    • 0028906017 scopus 로고
    • The cavitation threshold of human tissue exposed to 0.2-MHz pulsed ultrasound: Preliminary measurements based on a study of clinical lithotripsy
    • A. J. Coleman, T. Kodama, M. J. Choi, T. Adams, and J. E. Saunders, "The cavitation threshold of human tissue exposed to 0.2-MHz pulsed ultrasound: preliminary measurements based on a study of clinical lithotripsy," Ultrasound Med. Biol., vol. 21, pp. 405-117, 1995.
    • (1995) Ultrasound Med. Biol , vol.21 , pp. 405-117
    • Coleman, A.J.1    Kodama, T.2    Choi, M.J.3    Adams, T.4    Saunders, J.E.5
  • 13
    • 29144507666 scopus 로고    scopus 로고
    • Pulsed cavitational ultrasound therapy for controlled tissue homogenization
    • J. E. Parsons, C. A. Cain, G. D. Abrams, and J. B. Fowlkes, "Pulsed cavitational ultrasound therapy for controlled tissue homogenization," Ultrasound Med. Biol., vol. 32, pp. 115-129, 2006.
    • (2006) Ultrasound Med. Biol , vol.32 , pp. 115-129
    • Parsons, J.E.1    Cain, C.A.2    Abrams, G.D.3    Fowlkes, J.B.4
  • 14
    • 30344464424 scopus 로고    scopus 로고
    • Pulsed cavitational ultrasound: A noninvasive technology for controlled tissue ablation (histotripsy) in the rabbit kidney
    • W. W. Roberts, T. J. Hall, K. Ives, J. J. S. Wolf, J. B. Fowlkes, and C. A. Cain, "Pulsed cavitational ultrasound: A noninvasive technology for controlled tissue ablation (histotripsy) in the rabbit kidney," J. Urol., vol. 175, pp. 734-738, 2006.
    • (2006) J. Urol , vol.175 , pp. 734-738
    • Roberts, W.W.1    Hall, T.J.2    Ives, K.3    Wolf, J.J.S.4    Fowlkes, J.B.5    Cain, C.A.6
  • 15
    • 0025355280 scopus 로고
    • Hypoplastic left heart syndrome
    • L. L. Bailey and S. R. Gundry, "Hypoplastic left heart syndrome," Pediatr. Clin. No. Amer., vol. 37, pp. 137-150, 1990.
    • (1990) Pediatr. Clin. No. Amer , vol.37 , pp. 137-150
    • Bailey, L.L.1    Gundry, S.R.2
  • 16
    • 0021249783 scopus 로고
    • Thermal model for ultrasonic treatment of glaucoma
    • F. L. Lizzi, J. Driller, and M. Ostromogilsky, "Thermal model for ultrasonic treatment of glaucoma," Ultrasound Med. Biol., vol. 10, pp. 289-298, 1984.
    • (1984) Ultrasound Med. Biol , vol.10 , pp. 289-298
    • Lizzi, F.L.1    Driller, J.2    Ostromogilsky, M.3
  • 18
    • 84955015716 scopus 로고
    • Cavitation as a mechanism for the biological effects of ultrasound on plant roots
    • E. L. Carstensen, S. Z. Child, W. K. Law, D. R. Horowitz, and M. W. Miller, "Cavitation as a mechanism for the biological effects of ultrasound on plant roots," J. Acoust. Soc. Amer., vol. 66, pp. 1285-1291, 1979.
    • (1979) J. Acoust. Soc. Amer , vol.66 , pp. 1285-1291
    • Carstensen, E.L.1    Child, S.Z.2    Law, W.K.3    Horowitz, D.R.4    Miller, M.W.5
  • 19
    • 34447103095 scopus 로고    scopus 로고
    • Refining histotripsy: Defining the parameter space for the creation of nonthermal lesions with high intensity, pulsed focused ultrasound of the in vitro kidney
    • K. Kieran, T. L. Hall, J. E. Parsons, J. S. Wolf, J. B. Fowlkes, C. A. Cain, and W. W. Roberts, "Refining histotripsy: Defining the parameter space for the creation of nonthermal lesions with high intensity, pulsed focused ultrasound of the in vitro kidney," J. Urol., vol. 178, pp. 272-276, 2007.
    • (2007) J. Urol , vol.178 , pp. 272-276
    • Kieran, K.1    Hall, T.L.2    Parsons, J.E.3    Wolf, J.S.4    Fowlkes, J.B.5    Cain, C.A.6    Roberts, W.W.7
  • 20
    • 12344327720 scopus 로고    scopus 로고
    • Controlled ultrasound tissue erosion: The role of dynamic interaction between insonation and microbubble activity
    • Z. Xu, J. B. Fowlkes, E. D. Rothman, A. M. Levin, and C. A. Cain, "Controlled ultrasound tissue erosion: The role of dynamic interaction between insonation and microbubble activity," J. Acoust. Soc. Amer., vol. 117, pp. 424-135, 2005.
    • (2005) J. Acoust. Soc. Amer , vol.117 , pp. 424-135
    • Xu, Z.1    Fowlkes, J.B.2    Rothman, E.D.3    Levin, A.M.4    Cain, C.A.5
  • 21
    • 33947621117 scopus 로고    scopus 로고
    • Spatial variability in acoustic backscatter as an indicator of tissue homogenate production in pulsed cavitational ultrasound therapy
    • J. E. Parsons, C. A. Cain, G. D. Abrams, and J. B. Fowlkes, "Spatial variability in acoustic backscatter as an indicator of tissue homogenate production in pulsed cavitational ultrasound therapy," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 54, pp. 576-590, 2007.
    • (2007) IEEE Trans. Ultrason., Ferroelect., Freq. Contr , vol.54 , pp. 576-590
    • Parsons, J.E.1    Cain, C.A.2    Abrams, G.D.3    Fowlkes, J.B.4
  • 22
    • 0028076096 scopus 로고
    • In vivo detection of ultrasonically induced cavitation by a fibreoptic technique
    • P. Huber, J. Debus, P. Peschke, E. W. Hahn, and W. J. Lorenz, "In vivo detection of ultrasonically induced cavitation by a fibreoptic technique," Ultrasound Med. Biol., vol. 20, pp. 811-825, 1994.
    • (1994) Ultrasound Med. Biol , vol.20 , pp. 811-825
    • Huber, P.1    Debus, J.2    Peschke, P.3    Hahn, E.W.4    Lorenz, W.J.5
  • 23
    • 20444501636 scopus 로고    scopus 로고
    • Hyperecho in ultrasound images of HIFU therapy: Involvement of cavitation
    • S. Vaezy, B. A. Rabkin, and V. Zderic, "Hyperecho in ultrasound images of HIFU therapy: Involvement of cavitation," Ultrasound Med. Biol., vol. 31, pp. 947-956, 2005.
    • (2005) Ultrasound Med. Biol , vol.31 , pp. 947-956
    • Vaezy, S.1    Rabkin, B.A.2    Zderic, V.3
  • 24
    • 14344250450 scopus 로고    scopus 로고
    • Behaviour of a bubble cluster in an ultrasound field
    • Y. Matsumoto and S. Yoshizawa, "Behaviour of a bubble cluster in an ultrasound field," Int. J. Numer. Meth. Fluids, vol. 47, pp. 591-601, 2005.
    • (2005) Int. J. Numer. Meth. Fluids , vol.47 , pp. 591-601
    • Matsumoto, Y.1    Yoshizawa, S.2
  • 26
    • 0001572603 scopus 로고    scopus 로고
    • Cavitation nuclei and bubble formation-a dynamic liquid-solid interface problem
    • K. A. Mørch, "Cavitation nuclei and bubble formation-a dynamic liquid-solid interface problem," Trans. ASME, J. Fluids Eng., vol. 122, pp. 494-498, 2000.
    • (2000) Trans. ASME, J. Fluids Eng , vol.122 , pp. 494-498
    • Mørch, K.A.1
  • 27
    • 0022154262 scopus 로고
    • A precise technique for the measurement of acoustic cavitation thresholds and some preliminary results
    • R. A. Roy, A. A. Atchley, L. A. Crum, J. B. Fowlkes, and J. J. Reidy, "A precise technique for the measurement of acoustic cavitation thresholds and some preliminary results," J. Acoust. Soc. Amer., vol. 78, pp. 1799-1805, 1985.
    • (1985) J. Acoust. Soc. Amer , vol.78 , pp. 1799-1805
    • Roy, R.A.1    Atchley, A.A.2    Crum, L.A.3    Fowlkes, J.B.4    Reidy, J.J.5
  • 29
    • 0025258575 scopus 로고
    • Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment
    • C. K. Holland and R. E. Apfel, "Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment," J. Acoust. Soc. Amer., vol. 88, pp. 2059-2069, 1990.
    • (1990) J. Acoust. Soc. Amer , vol.88 , pp. 2059-2069
    • Holland, C.K.1    Apfel, R.E.2
  • 30
    • 28844454163 scopus 로고    scopus 로고
    • Investigation of intensity threshold for ultrasound tissue erosion
    • Z. Xu, J. B. Fowlkes, A. Ludomirsky, and C. A. Cain, "Investigation of intensity threshold for ultrasound tissue erosion," Ultrasound Med. Biol., vol. 31, pp. 1673-1682, 2005.
    • (2005) Ultrasound Med. Biol , vol.31 , pp. 1673-1682
    • Xu, Z.1    Fowlkes, J.B.2    Ludomirsky, A.3    Cain, C.A.4
  • 33
    • 33644661136 scopus 로고    scopus 로고
    • Cost-effective assembly of a basic fiber-optic hydrophone for measurement of high-amplitude therapeutic ultrasound fields
    • J. E. Parsons, C. A. Cain, and J. B. Fowlkes, "Cost-effective assembly of a basic fiber-optic hydrophone for measurement of high-amplitude therapeutic ultrasound fields," J. Acoust. Soc. Amer., vol. 119, pp. 1432-1440, 2006.
    • (2006) J. Acoust. Soc. Amer , vol.119 , pp. 1432-1440
    • Parsons, J.E.1    Cain, C.A.2    Fowlkes, J.B.3
  • 34
    • 37049009851 scopus 로고    scopus 로고
    • AIUM, Acoustic Output Measurement Standard for Diagnostic Ultrasound Equipment UD2-98. Laurel, MD: AIUM/NEMA, 1998.
    • AIUM, Acoustic Output Measurement Standard for Diagnostic Ultrasound Equipment UD2-98. Laurel, MD: AIUM/NEMA, 1998.
  • 37
    • 33947660790 scopus 로고    scopus 로고
    • Acoustic backscatter features associated with production of tissue homogenate using pulsed cavitational ultrasound therapy
    • J. E. Parsons, J. B. Fowlkes, and C. A. Cain, "Acoustic backscatter features associated with production of tissue homogenate using pulsed cavitational ultrasound therapy," in Proc. Int. Symp. Therapeut Ultrasound, 2005, pp. 323-327.
    • (2005) Proc. Int. Symp. Therapeut Ultrasound , pp. 323-327
    • Parsons, J.E.1    Fowlkes, J.B.2    Cain, C.A.3
  • 38
    • 33947615606 scopus 로고    scopus 로고
    • Optical and acoustic monitoring of bubble dynamics at a tissue-fluid interface in ultrasound tissue erosion
    • Z. Xu, J. B. Fowlkes, and C. A. Cain, "Optical and acoustic monitoring of bubble dynamics at a tissue-fluid interface in ultrasound tissue erosion," in Proc. Int. Symp. Therapeut. Ultrasound, 2005, pp. 343-347.
    • (2005) Proc. Int. Symp. Therapeut. Ultrasound , pp. 343-347
    • Xu, Z.1    Fowlkes, J.B.2    Cain, C.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.