메뉴 건너뛰기




Volumn 51, Issue 1-2, 2008, Pages 283-293

Free convective heat transfer in an enclosure with an internal louvered blind

Author keywords

Blind; Correlation; Fenestration; Free convection; Louvers; Numerical simulation

Indexed keywords

COMPUTER SIMULATION; CORRELATION METHODS; NUMERICAL METHODS; NUSSELT NUMBER;

EID: 36849084661     PISSN: 00179310     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijheatmasstransfer.2007.03.042     Document Type: Article
Times cited : (32)

References (29)
  • 1
    • 36849017173 scopus 로고    scopus 로고
    • E.U. Finlayson, D.K. Arasteh, C. Huizenga, M.D. Rubin, M.S. Reilly, WINDOW: Documentation of calculation procedures, Energy and Environmental Division, Lawrence Berkeley Laboratory, Berkeley, CA, USA, 1993.
  • 2
    • 36849023603 scopus 로고    scopus 로고
    • National Fenestration Rating Council Incorporated, Procedure for determining fenestration product U-factors, NFRC 100:2001, Silver Spring, MD, USA, 2002.
  • 3
    • 36849005715 scopus 로고    scopus 로고
    • Canadian Standards Association, Energy performance of windows and other fenestration systems, Standard A440.2-98, Etobicoke, Ontario, Canada, 1998.
  • 4
    • 36849072144 scopus 로고    scopus 로고
    • J.L. Wright, H.F. Sullivan, VISION3 Glazing system thermal analysis: Reference manual, Advanced Glazing Laboratory, Department of Mechanical Engineering, University of Waterloo, Waterloo, Ontario, Canada, 1992.
  • 5
    • 2442444281 scopus 로고    scopus 로고
    • Heat transfer analysis of a between-panes venetian blind using effective longwave radiative properties
    • Yahoda D.S., and Wright J.L. Heat transfer analysis of a between-panes venetian blind using effective longwave radiative properties. ASHRAE Trans. 110 1 (2004) 455-462
    • (2004) ASHRAE Trans. , vol.110 , Issue.1 , pp. 455-462
    • Yahoda, D.S.1    Wright, J.L.2
  • 6
    • 18844396456 scopus 로고    scopus 로고
    • Energy performance of a window with a horizontal venetian blind
    • Shahid H., and Naylor D. Energy performance of a window with a horizontal venetian blind. Energy Build. 37 8 (2005) 836-843
    • (2005) Energy Build. , vol.37 , Issue.8 , pp. 836-843
    • Shahid, H.1    Naylor, D.2
  • 7
    • 33744464491 scopus 로고    scopus 로고
    • A simplified method for modeling the effect of blinds on window thermal performance
    • Naylor D., Shahid D.H., Harrison S.J., and Oosthuizen P.H. A simplified method for modeling the effect of blinds on window thermal performance. Int. J. Energy Res. 30 (2006) 471-488
    • (2006) Int. J. Energy Res. , vol.30 , pp. 471-488
    • Naylor, D.1    Shahid, D.H.2    Harrison, S.J.3    Oosthuizen, P.H.4
  • 8
    • 0029140211 scopus 로고
    • The effect of slat angle of windows with venetian blinds on heating and cooling loads of buildings in South Korea
    • Cho S.-W., Shin K.-S., and Zaheer-Uddin M. The effect of slat angle of windows with venetian blinds on heating and cooling loads of buildings in South Korea. Energy 20 12 (1995) 1125-1236
    • (1995) Energy , vol.20 , Issue.12 , pp. 1125-1236
    • Cho, S.-W.1    Shin, K.-S.2    Zaheer-Uddin, M.3
  • 9
    • 0346323081 scopus 로고
    • Heat transfer analysis in an automated venetian blind window system
    • Rheault S., and Bilgen E. Heat transfer analysis in an automated venetian blind window system. J. Sol. Energy Eng. 111 (1989) 89-95
    • (1989) J. Sol. Energy Eng. , vol.111 , pp. 89-95
    • Rheault, S.1    Bilgen, E.2
  • 10
    • 0034459202 scopus 로고    scopus 로고
    • Estimation of annual energy-savings contribution of an automated blind system
    • Ullah M.B., and Lefebvre G. Estimation of annual energy-savings contribution of an automated blind system. ASHRAE Trans. 106 (2000) 408-418
    • (2000) ASHRAE Trans. , vol.106 , pp. 408-418
    • Ullah, M.B.1    Lefebvre, G.2
  • 11
    • 0026155766 scopus 로고
    • Natural convection in a vertical enclosure with permeable screen
    • Zhang Z., Bejan A., and Lage J.L. Natural convection in a vertical enclosure with permeable screen. J. Heat Transfer 113 (1991) 337-383
    • (1991) J. Heat Transfer , vol.113 , pp. 337-383
    • Zhang, Z.1    Bejan, A.2    Lage, J.L.3
  • 12
    • 36849050473 scopus 로고    scopus 로고
    • J.M. Garnet, Thermal performance of windows with inter-pane venetian blinds, M.A.Sc. thesis, University of Waterloo, Waterloo, Ontario, Canada, 1999.
  • 13
    • 36849089330 scopus 로고    scopus 로고
    • R. Dalal, Thermal analysis of a double glazed window with a between-panes pleated blind, M.Eng. Thesis, Ryerson University, Toronto, Ontario, Canada, 2004.
  • 14
    • 36849009949 scopus 로고    scopus 로고
    • N.Y.-T. Huang, Thermal performance of double glazed windows with inter-pane venetian blinds, Masters Thesis, University of Waterloo, Waterloo, Ontario, Canada, 2005.
  • 15
    • 33847092020 scopus 로고    scopus 로고
    • Experimental study of natural convection in a window with a between-panes venetian blind
    • Naylor D., and Lai B.Y. Experimental study of natural convection in a window with a between-panes venetian blind. Exp. Heat Transfer 20 (2007) 1-17
    • (2007) Exp. Heat Transfer , vol.20 , pp. 1-17
    • Naylor, D.1    Lai, B.Y.2
  • 16
    • 21744435260 scopus 로고    scopus 로고
    • Three-dimensional simulation with a CFD tool of airflow phenomena in a single floor double-skin facade equipped with a venetian blind
    • Safer N., Woloszyn M., and Roux J.J. Three-dimensional simulation with a CFD tool of airflow phenomena in a single floor double-skin facade equipped with a venetian blind. Solar Energy 79 (2005) 193-203
    • (2005) Solar Energy , vol.79 , pp. 193-203
    • Safer, N.1    Woloszyn, M.2    Roux, J.J.3
  • 17
    • 0034140468 scopus 로고    scopus 로고
    • A study of the U-factor of the window with a high-reflectivity venetian blind
    • Fang X.D. A study of the U-factor of the window with a high-reflectivity venetian blind. Solar Energy 60 2 (2000) 207-214
    • (2000) Solar Energy , vol.60 , Issue.2 , pp. 207-214
    • Fang, X.D.1
  • 18
    • 0026221978 scopus 로고
    • Natural convection in slender cavities with multiple fins attached to an active wall
    • Scozia R., and Frederick R.L. Natural convection in slender cavities with multiple fins attached to an active wall. Numer. Heat Transfer, Part A: Appl. 20 2 (1991) 127-158
    • (1991) Numer. Heat Transfer, Part A: Appl. , vol.20 , Issue.2 , pp. 127-158
    • Scozia, R.1    Frederick, R.L.2
  • 19
    • 36849010420 scopus 로고    scopus 로고
    • N.A. Kotey, J.L. Wright, Simplified solar optical calculations for windows with venetian blinds, in: Proceedings of the 31st Conference of the Solar Energy Society of Canada, Montreal, Canada, 2006, pp. 1-8.
  • 20
    • 0029706382 scopus 로고    scopus 로고
    • Calorimetric measurements of inward-flowing fraction for complex glazing and shading systems
    • Klems J.H., and Kelly G.O. Calorimetric measurements of inward-flowing fraction for complex glazing and shading systems. ASHRAE Trans. 102 1 (1996) 947-954
    • (1996) ASHRAE Trans. , vol.102 , Issue.1 , pp. 947-954
    • Klems, J.H.1    Kelly, G.O.2
  • 22
    • 0021412675 scopus 로고
    • Enhancement of the simple method for predicting incompressible flows
    • Van Doormal J.P., and Raithby G.D. Enhancement of the simple method for predicting incompressible flows. Numer. Heat Transfer 7 (1984) 47-163
    • (1984) Numer. Heat Transfer , vol.7 , pp. 47-163
    • Van Doormal, J.P.1    Raithby, G.D.2
  • 23
    • 36849051626 scopus 로고    scopus 로고
    • T. Avedissian, A numerical study of free convective heat transfer in a double glazed window with a between-pane venetian blind, M.A.Sc Thesis, Ryerson University, Toronto, Ontario, Canada, 2006.
  • 24
    • 36849086647 scopus 로고    scopus 로고
    • B. Lai, An interferometric study of free convective heat transfer in a double glazed window with a between-panes venetian blind, M.A.Sc Thesis, Ryerson University, Toronto, Ontario, Canada, 2004.
  • 25
    • 2442476930 scopus 로고
    • Glazing system U-value measurement using a guarded heater plate apparatus
    • Wright J.L., and Sullivan H.F. Glazing system U-value measurement using a guarded heater plate apparatus. ASHRAE Trans. 94 2 (1988) 1325-1337
    • (1988) ASHRAE Trans. , vol.94 , Issue.2 , pp. 1325-1337
    • Wright, J.L.1    Sullivan, H.F.2
  • 26
    • 36849081593 scopus 로고    scopus 로고
    • Personal conversation with Professor J.L. Wright at the Department of Mechanical Engineering, University of Waterloo, Waterloo, Ontario, Canada, February 20, 2004.
  • 27
    • 0029697557 scopus 로고    scopus 로고
    • A correlation to quantify convective heat transfer between vertical window glazings
    • Wright J.L. A correlation to quantify convective heat transfer between vertical window glazings. ASHRAE Trans. 102 1 (1996) 940-946
    • (1996) ASHRAE Trans. , vol.102 , Issue.1 , pp. 940-946
    • Wright, J.L.1
  • 28
    • 13844267049 scopus 로고    scopus 로고
    • Evaluation of an approximate method for predicting the U-value of a window with a between-panes blind
    • Naylor D., and Collins M.R. Evaluation of an approximate method for predicting the U-value of a window with a between-panes blind. Numer. Heat Transfer, Part A - Appl. 47 3 (2005) 233-250
    • (2005) Numer. Heat Transfer, Part A - Appl. , vol.47 , Issue.3 , pp. 233-250
    • Naylor, D.1    Collins, M.R.2
  • 29
    • 33750289860 scopus 로고    scopus 로고
    • Calculating performance indices for windows with diathermanous layers
    • Collins M.R., and Wright J.L. Calculating performance indices for windows with diathermanous layers. ASHRAE Trans. 112 2 (2006) 22-29
    • (2006) ASHRAE Trans. , vol.112 , Issue.2 , pp. 22-29
    • Collins, M.R.1    Wright, J.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.