A randomized, bilateral, prospective comparison of calcium hydroxylapatite microspheres versus human-based collagen for the correction of nasolabial folds

Author keywords

[No Author keywords available]

Indexed keywords

COLLAGEN; HYDROXYAPATITE; MICROSPHERE; HYALURONIC ACID;

EID: 36849070296     PISSN: 10760512     EISSN: 15244725     Source Type: Journal    
DOI: 10.1111/j.1524-4725.2007.33350.x     Document Type: Article
Times cited : (85)

References (13)
  • 1
    • 36849073176 scopus 로고    scopus 로고
    • The dermal fillers revolution
    • In: Aliso Viejo (CA): Medical Insight, Inc. p.
    • Moretti M. The dermal fillers revolution. In : Aesthetic Buyers Guide. Aliso Viejo (CA) : Medical Insight, Inc 2006. p. 114 34.
    • (2006) Aesthetic Buyers Guide. , pp. 114-134
    • Moretti, M.1
  • 2
    • 36849023883 scopus 로고    scopus 로고
    • Wrinkle fillers could face off in '06: Medicis'drug Restylane could see competition from Inamed's Juvederm in 2006 [monograph on the Internet]. Atlanta: Cable News Network LP; 2006 Jan 11 [accessed 2006 Apr 13]. Available from:
    • Smith A. Wrinkle fillers could face off in '06: Medicis' drug Restylane could see competition from Inamed's Juvederm in 2006 [monograph on the Internet]. Atlanta: Cable News Network LP; 2006 Jan 11 [accessed 2006 Apr 13]. Available from :
    • Smith, A.1
  • 3
    • 0022600011 scopus 로고
    • Biomaterial aspects of calcium phosphates: Properties and applications
    • Jarcho M. Biomaterial aspects of calcium phosphates: properties and applications. Dent Clin North Am 1986 30 : 25 47.
    • (1986) Dent Clin North Am , vol.30 , pp. 25-47
    • Jarcho, M.1
  • 4
    • 0032809031 scopus 로고    scopus 로고
    • Resorbable bioceramics based on stabilized calcium phosphates. Part I. rational design, sample preparation and material characterization
    • Langstaff S, Sayer M, Smith TJ, et al. Resorbable bioceramics based on stabilized calcium phosphates. Part I. rational design, sample preparation and material characterization. Biomaterials 1999 20 : 1727 41.
    • (1999) Biomaterials , vol.20 , pp. 1727-1741
    • Langstaff, S.1    Sayer, M.2    Smith, T.J.3
  • 5
    • 0036561951 scopus 로고    scopus 로고
    • Histologic evaluation of a hydroxyapatite onlay bone graft retrieved after 9 years: A clinical report
    • Proussaefs P, Lozada J, Valencia G, Rohrer MD. Histologic evaluation of a hydroxyapatite onlay bone graft retrieved after 9 years: a clinical report. J Prosthet Dent 2002 87 : 481 4.
    • (2002) J Prosthet Dent , vol.87 , pp. 481-484
    • Proussaefs, P.1    Lozada, J.2    Valencia, G.3    Rohrer, M.D.4
  • 6
  • 7
    • 17444397718 scopus 로고    scopus 로고
    • Clinical, histological and electron microscope findings after injection of a calcium hydroxylapatite filler
    • Marmur ES, Phelps R, Goldberg DJ. Clinical, histological and electron microscope findings after injection of a calcium hydroxylapatite filler. J Cosmet Laser Ther 2004 6 : 223 6.
    • (2004) J Cosmet Laser Ther , vol.6 , pp. 223-226
    • Marmur, E.S.1    Phelps, R.2    Goldberg, D.J.3
  • 8
    • 1642389398 scopus 로고    scopus 로고
    • Human histology and persistence of various injectable filler substances for soft tissue augmentation
    • discussion 367.
    • Lemperle G, Morhenn V, Charrier U. Human histology and persistence of various injectable filler substances for soft tissue augmentation. Aesthetic Plast Surg 2003 27 : 354 discussion 367.
    • (2003) Aesthetic Plast Surg , vol.27 , pp. 354
    • Lemperle, G.1    Morhenn, V.2    Charrier, U.3
  • 10
    • 0038792656 scopus 로고    scopus 로고
    • A randomized, double-blind, multicenter comparison of the efficacy and tolerability of Restylane versus Zyplast for the correction of nasolabial folds
    • Narins R, Brandt F, Leyden J, et al. A randomized, double-blind, multicenter comparison of the efficacy and tolerability of Restylane versus Zyplast for the correction of nasolabial folds. Dermatol Surg 2003 29 : 588 95.
    • (2003) Dermatol Surg , vol.29 , pp. 588-595
    • Narins, R.1    Brandt, F.2    Leyden, J.3
  • 11
    • 0017360990 scopus 로고
    • The measurement of observer variation for categorical data
    • Landis JR, Koch GS. The measurement of observer variation for categorical data. Biometrics 1977 33 : 159 74.
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.S.2
  • 12
    • 33646718141 scopus 로고    scopus 로고
    • Thrombin generation by activated factor VII on platelet activated by different agonists: Extending the cell-based model of hemostasis
    • Altman R, Scazziota AS, Lourdes Herrera DE, Gonzalez C. Thrombin generation by activated factor VII on platelet activated by different agonists: extending the cell-based model of hemostasis. Thromb J 2006 4 : 5.
    • (2006) Thromb J , vol.4 , pp. 5
    • Altman, R.1    Scazziota, A.S.2    Lourdes Herrera, D.E.3    Gonzalez, C.4
  • 13
    • 36849057637 scopus 로고    scopus 로고
    • Use of injectable calcium hydroxlapatite (Radiesse) versus hyaluronic acid (Restylane) for treatment of nasolabial folds. Poster Presentation at the Apr; Orlando, FL.
    • Moers-Carpi M. Use of injectable calcium hydroxlapatite (Radiesse) versus hyaluronic acid (Restylane) for treatment of nasolabial folds. Poster Presentation at the Annual Meeting of the American Society for Aesthetic Plastic Surgery; 2006 Apr; Orlando, FL.
    • (2006) Annual Meeting of the American Society for Aesthetic Plastic Surgery
    • Moers-Carpi, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.