메뉴 건너뛰기




Volumn 48, Issue 12, 2007, Pages 2080-2086

Posttherapy radiation safety considerations in radiomicrosphere treatment with 90Y-microspheres

Author keywords

90Y; Microspheres; Radiation safety; Radiomicrosphere treatment; Selective internal radiation treatment

Indexed keywords

MICROSPHERE Y 90; TRACER; UNCLASSIFIED DRUG;

EID: 36849008049     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: 10.2967/jnumed.107.045443     Document Type: Article
Times cited : (46)

References (26)
  • 1
    • 0014082152 scopus 로고
    • Treatment of inoperable cancer of the liver by intra-arterial radioactive isotopes and chemotherapy
    • Ariel IM, Pack GT. Treatment of inoperable cancer of the liver by intra-arterial radioactive isotopes and chemotherapy. Cancer. 1967;20:793-804.
    • (1967) Cancer , vol.20 , pp. 793-804
    • Ariel, I.M.1    Pack, G.T.2
  • 3
    • 0035700227 scopus 로고    scopus 로고
    • Randomized trial of SIR-spheres plus chemotherapy vs chemotherapy alone for treating patients with liver metastases from primary large bowel cancer
    • Gray B, Van Hazel G, Hope M, et al. Randomized trial of SIR-spheres plus chemotherapy vs chemotherapy alone for treating patients with liver metastases from primary large bowel cancer. Ann Oncol. 2001;12:1711-1720.
    • (2001) Ann Oncol , vol.12 , pp. 1711-1720
    • Gray, B.1    Van Hazel, G.2    Hope, M.3
  • 4
    • 33750156243 scopus 로고    scopus 로고
    • Radioembolization with yttrium-90 microspheres: A state-of-the-art brachytherapy treatment for primary and secondary liver malignancies: part 3 - comprehensive literature review and future direction
    • Salem R, Thurston KG. Radioembolization with yttrium-90 microspheres: a state-of-the-art brachytherapy treatment for primary and secondary liver malignancies: part 3 - comprehensive literature review and future direction. J Vasc Interv Radiol. 2006;17:1571-1593.
    • (2006) J Vasc Interv Radiol , vol.17 , pp. 1571-1593
    • Salem, R.1    Thurston, K.G.2
  • 5
    • 34447502039 scopus 로고    scopus 로고
    • Yttrium 90 microsphere selective internal radiation treatment of hepatic colorectal metastases
    • Gulec SA, Fong Y. Yttrium 90 microsphere selective internal radiation treatment of hepatic colorectal metastases. Arch Surg. 2007;142:675-682.
    • (2007) Arch Surg , vol.142 , pp. 675-682
    • Gulec, S.A.1    Fong, Y.2
  • 6
    • 36849043908 scopus 로고    scopus 로고
    • Sirtex Medical. SIR-Spheres yttrium-90 microspheres, package insert, Available at:, Accessed October 16, 2007
    • Sirtex Medical. SIR-Spheres (yttrium-90 microspheres) [package insert]. Available at: http://www.sirtex.com/. Accessed October 16, 2007.
  • 8
    • 36849011328 scopus 로고    scopus 로고
    • MDS Nordion. TheraSphere yttrium-90 glass microsphere, package insert, Available at:, Accessed October 16, 2007
    • MDS Nordion. TheraSphere (yttrium-90 glass microsphere) [package insert]. Available at: http://www.mdsnordion.com/. Accessed October 16, 2007.
  • 9
    • 36849043907 scopus 로고    scopus 로고
    • U.S. Nuclear Regulatory Commission, Washington, DC: U.S. Nuclear Regulatory Commission;, NRC Information Notice
    • U.S. Nuclear Regulatory Commission. 2007-10: Yttrium-90 Theraspheres and SirSpheres Impurities. Washington, DC: U.S. Nuclear Regulatory Commission; 2007. NRC Information Notice.
    • (2007) 2007-10: Yttrium-90 Theraspheres and SirSpheres Impurities
  • 10
    • 0027676322 scopus 로고
    • 2 glasses for the in vivo delivery of beta radiation
    • 2 glasses for the in vivo delivery of beta radiation. J Biomed Mater Res. 1993;27:1301-1308.
    • (1993) J Biomed Mater Res , vol.27 , pp. 1301-1308
    • Erbe, E.M.1    Day, D.E.2
  • 11
    • 36849095330 scopus 로고    scopus 로고
    • U.S. Nuclear Regulatory Commission. Criteria for the Release of Individuals Administered Radioactive Material. 10 CFR Parts 20 and 35: 62 FR 4120. Washington, DC: U.S. Nuclear Regulatory Commission; 1997.
    • U.S. Nuclear Regulatory Commission. Criteria for the Release of Individuals Administered Radioactive Material. 10 CFR Parts 20 and 35: 62 FR 4120. Washington, DC: U.S. Nuclear Regulatory Commission; 1997.
  • 12
    • 36849079113 scopus 로고    scopus 로고
    • U.S. Nuclear Regulatory Commission. Model Procedure for Release of Patients or Human Research Subjects Administered Radioactive Materials. NUREG-1556, 9, Rev. 1, Appendix U. Washington, DC: U.S. Nuclear Regulatory Commission; 2005:U-5.
    • U.S. Nuclear Regulatory Commission. Model Procedure for Release of Patients or Human Research Subjects Administered Radioactive Materials. NUREG-1556, Vol. 9, Rev. 1, Appendix U. Washington, DC: U.S. Nuclear Regulatory Commission; 2005:U-5.
  • 13
    • 0033029005 scopus 로고    scopus 로고
    • Bremsstrahlung radiation exposure from pure β-ray emitters
    • Zanzonico PB, Binkert BL, Goldsmith SJ. Bremsstrahlung radiation exposure from pure β-ray emitters. J Nucl Med. 1999;40:1024-1028.
    • (1999) J Nucl Med , vol.40 , pp. 1024-1028
    • Zanzonico, P.B.1    Binkert, B.L.2    Goldsmith, S.J.3
  • 15
    • 0036733627 scopus 로고    scopus 로고
    • Calculating the absorbed dose to others from the radioactive patient: Line source model versus point source model
    • Siegel JA, Marcus CS, Sparks RB. Calculating the absorbed dose to others from the radioactive patient: line source model versus point source model. J Nucl Med. 2002;43:1241-1244.
    • (2002) J Nucl Med , vol.43 , pp. 1241-1244
    • Siegel, J.A.1    Marcus, C.S.2    Sparks, R.B.3
  • 17
    • 0008335626 scopus 로고    scopus 로고
    • Radiation exposure is very low to the family members of patients treated with yttrium-90 Zevalin anti-CD20 monoclonal antibody therapy for lymphoma [abstract]
    • Wiseman GA, Leigh B, Witzig T, Gansen D, White C. Radiation exposure is very low to the family members of patients treated with yttrium-90 Zevalin anti-CD20 monoclonal antibody therapy for lymphoma [abstract]. Eur J Nucl Med. 2001;28:1198.
    • (2001) Eur J Nucl Med , vol.28 , pp. 1198
    • Wiseman, G.A.1    Leigh, B.2    Witzig, T.3    Gansen, D.4    White, C.5
  • 18
    • 0034118365 scopus 로고    scopus 로고
    • Breast milk excretion of radiopharmaceuticals: Mechanisms, findings, and radiation dosimetry
    • Stabin MG, Breitz HB. Breast milk excretion of radiopharmaceuticals: mechanisms, findings, and radiation dosimetry. J Nucl Med. 2000;41:863-873.
    • (2000) J Nucl Med , vol.41 , pp. 863-873
    • Stabin, M.G.1    Breitz, H.B.2
  • 19
    • 0030002992 scopus 로고    scopus 로고
    • Stabin MG. MIRDOSE: personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 1996;37:538-546
    • Stabin MG. MIRDOSE: personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 1996;37:538-546.
  • 20
    • 19444373467 scopus 로고    scopus 로고
    • Estimation of the dose to the nursing infant due to direct irradiation from activity present in maternal organs and tissues
    • Hunt JG, Nosske D, dos Santos DS. Estimation of the dose to the nursing infant due to direct irradiation from activity present in maternal organs and tissues. Radiat Prot Dosimetry. 2005;113:290-299.
    • (2005) Radiat Prot Dosimetry , vol.113 , pp. 290-299
    • Hunt, J.G.1    Nosske, D.2    dos Santos, D.S.3
  • 21
    • 0028016185 scopus 로고
    • Bremsstrahlung radiation dose in yttrium-90 therapy applications
    • Stabin MG, Eckerman KF, Ryman JC, Williams LE. Bremsstrahlung radiation dose in yttrium-90 therapy applications. J Nucl Med. 1994;35:1377-1380.
    • (1994) J Nucl Med , vol.35 , pp. 1377-1380
    • Stabin, M.G.1    Eckerman, K.F.2    Ryman, J.C.3    Williams, L.E.4
  • 22
    • 36849001618 scopus 로고    scopus 로고
    • Brent RL. Developmental and reproductive risks of radiological procedures utilizing ionizing radiation during pregnancy. In: Radiation Protection in Medicine: Contemporary Issues. Proceedings of the Thirty-Fifth Annual Meeting of the National Council on Radiation Protection and Measurements. Proceedings No. 21. Arlington, VA: National Council on Radiation Protection and Measurements; 1999:43-47.
    • Brent RL. Developmental and reproductive risks of radiological procedures utilizing ionizing radiation during pregnancy. In: Radiation Protection in Medicine: Contemporary Issues. Proceedings of the Thirty-Fifth Annual Meeting of the National Council on Radiation Protection and Measurements. Proceedings No. 21. Arlington, VA: National Council on Radiation Protection and Measurements; 1999:43-47.
  • 24
    • 0028227876 scopus 로고
    • Quantitative bremsstrahlung SPECT imaging: Attenuation-corrected activity determination
    • Siegel JA. Quantitative bremsstrahlung SPECT imaging: attenuation-corrected activity determination. J Nucl Med. 1994;35:1213-1216.
    • (1994) J Nucl Med , vol.35 , pp. 1213-1216
    • Siegel, J.A.1
  • 25
    • 0027937092 scopus 로고
    • Quantitative bremsstrahlung imaging of Y-90 using a Wiener filter
    • Shen S, DeNardo GL, DeNardo SJ. Quantitative bremsstrahlung imaging of Y-90 using a Wiener filter. Med Phys. 1994;21:1409-1417.
    • (1994) Med Phys , vol.21 , pp. 1409-1417
    • Shen, S.1    DeNardo, G.L.2    DeNardo, S.J.3
  • 26
    • 0028962714 scopus 로고    scopus 로고
    • Siegel JA, Zeiger LS, Order SE, Wallner PE. Quantitative bremsstrahlung SPECT imaging: use for activity, and absorbed dose calculations. Int J Radiat Oncol Biol Phys. 1995;31:953-958.
    • Siegel JA, Zeiger LS, Order SE, Wallner PE. Quantitative bremsstrahlung SPECT imaging: use for volume, activity, and absorbed dose calculations. Int J Radiat Oncol Biol Phys. 1995;31:953-958.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.