메뉴 건너뛰기




Volumn 3, Issue , 2007, Pages 2995-3007

Thrust stand micro-mass balance diagnostic techniques for the direct measurement of specific impulse

Author keywords

[No Author keywords available]

Indexed keywords

LASER ABLATION; MASS TRANSFER; MATHEMATICAL MODELS; ROTATION; SOLID PROPELLANTS;

EID: 36749056926     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.2514/6.2007-5300     Document Type: Conference Paper
Times cited : (2)

References (11)
  • 2
    • 0030144636 scopus 로고    scopus 로고
    • Laboratory-Scale Hybrid Rocket Motor Uncertainty
    • Fredrick, R.A. and Greiner, B.E., "Laboratory-Scale Hybrid Rocket Motor Uncertainty," Journal of Propulsion and Power, Vol. 12, No. 3, pp. 605-611, 1996.
    • (1996) Journal of Propulsion and Power , vol.12 , Issue.3 , pp. 605-611
    • Fredrick, R.A.1    Greiner, B.E.2
  • 6
    • 11844305649 scopus 로고    scopus 로고
    • Ablative Laser Propulsion: Determination of Specific Impulse from Plasma Imaging
    • Lin, J., Thompson, M.S., and Pakhomov,A.V.,"Ablative Laser Propulsion: Determination of Specific Impulse from Plasma Imaging," High-Power Laser Ablation V, SPIE Proceedings, (5448), pp. 465-476, 2004.
    • (2004) High-Power Laser Ablation V, SPIE Proceedings , vol.5448 , pp. 465-476
    • Lin, J.1    Thompson, M.S.2    Pakhomov, A.V.3
  • 7
    • 33845431122 scopus 로고    scopus 로고
    • Investigation of time-dependent forces on a nano-Newton-second impulse balance
    • 015105, pp
    • D'Souza, B.C., and Ketsdever, A.D., "Investigation of time-dependent forces on a nano-Newton-second impulse balance," Review of Scientific Instruments, Vol. 76, No. 1, 015105, pp. 1-10, 2005.
    • (2005) Review of Scientific Instruments , vol.76 , Issue.1 , pp. 1-10
    • D'Souza, B.C.1    Ketsdever, A.D.2
  • 8
    • 18744407839 scopus 로고    scopus 로고
    • Gas Dynamic Calibration of a nano-Newton Thrust Stand
    • Jamison, A., Ketsdever, A.D., and Muntz, E.P., "Gas Dynamic Calibration of a nano-Newton Thrust Stand," Review of Scientific Instruments, Vol. 73, No. 10, pp. 3629-3637, 2002.
    • (2002) Review of Scientific Instruments , vol.73 , Issue.10 , pp. 3629-3637
    • Jamison, A.1    Ketsdever, A.D.2    Muntz, E.P.3
  • 9
    • 0346306073 scopus 로고    scopus 로고
    • Comparison of force balance calibration techniques for the nano-Newton range
    • Selden, N., and Ketsdever, A.D., "Comparison of force balance calibration techniques for the nano-Newton range," Review of Scientific Instruments, Vol. 74, No. 12, pp. 5249-5254, 2003.
    • (2003) Review of Scientific Instruments , vol.74 , Issue.12 , pp. 5249-5254
    • Selden, N.1    Ketsdever, A.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.