메뉴 건너뛰기




Volumn 41, Issue 4, 2007, Pages 283-290

CFD modeling to improve the design of a fog system for cooling greenhouses

Author keywords

CFD; Fog cooling system; Glasshouse; Natural ventilation; Wind speed

Indexed keywords


EID: 36749025692     PISSN: 00213551     EISSN: None     Source Type: Journal    
DOI: 10.6090/jarq.41.283     Document Type: Article
Times cited : (12)

References (18)
  • 2
    • 85036992452 scopus 로고    scopus 로고
    • Al-Helal, I. M. (1998) A computational fluid dynamics study of natural ventilation in arid region greenhouses. Ph.D. diss. Ohio State University, Columbus, USA, pp.186.
    • Al-Helal, I. M. (1998) A computational fluid dynamics study of natural ventilation in arid region greenhouses. Ph.D. diss. Ohio State University, Columbus, USA, pp.186.
  • 3
    • 0000896792 scopus 로고    scopus 로고
    • Performance of a fog system for cooling greenhouses
    • Arbel, A., Yekutieli, O. & Barak, M. (1999) Performance of a fog system for cooling greenhouses. J. Agric. Eng. Res., 72, 129-136.
    • (1999) J. Agric. Eng. Res , vol.72 , pp. 129-136
    • Arbel, A.1    Yekutieli, O.2    Barak, M.3
  • 4
    • 0037239324 scopus 로고    scopus 로고
    • Combination of forced ventilation and fogging systems for cooling greenhouses
    • Arbel, A., Barak, M. & Shklyar, A. (2003) Combination of forced ventilation and fogging systems for cooling greenhouses. Biosystems Eng., 84(1), 45-55.
    • (2003) Biosystems Eng , vol.84 , Issue.1 , pp. 45-55
    • Arbel, A.1    Barak, M.2    Shklyar, A.3
  • 5
    • 2342506123 scopus 로고
    • Environmental control for animals and plants
    • ASHRAE , ASHRAE, Atlanta, USA
    • ASHRAE (1972) Environmental control for animals and plants. In ASHRAE handbook of fundamentals, ASHRAE, Atlanta, USA, 177-186.
    • (1972) ASHRAE handbook of fundamentals , pp. 177-186
  • 7
    • 0037242094 scopus 로고    scopus 로고
    • Determination of greenhouse-specific aspects of ventilation using three-dimensional computational fluid dynamics
    • Campen, J. B. & Bot, G. P. A. (2003) Determination of greenhouse-specific aspects of ventilation using three-dimensional computational fluid dynamics. Biosystems Eng., 84(1), 69-77.
    • (2003) Biosystems Eng , vol.84 , Issue.1 , pp. 69-77
    • Campen, J.B.1    Bot, G.P.A.2
  • 8
    • 85037001048 scopus 로고    scopus 로고
    • Fluent Inc. (1998) FLUENT 5 user's guide. Lebanon, USA. Available online at http://venus.imp.mx/hilario/ SuperComputo/Fluent.Inc/manuals/fluent5/ug/.
    • Fluent Inc. (1998) FLUENT 5 user's guide. Lebanon, USA. Available online at http://venus.imp.mx/hilario/ SuperComputo/Fluent.Inc/manuals/fluent5/ug/.
  • 9
    • 0016462499 scopus 로고
    • 2nd ed. McGraw-Hill, New York, USA, pp
    • Hinze, J. O. (1975) Turbulence, 2nd ed. McGraw-Hill, New York, USA, pp.790.
    • (1975) Turbulence , pp. 790
    • Hinze, J.O.1
  • 10
    • 0032079209 scopus 로고    scopus 로고
    • A CFD evaluation of naturally ventilated, multi-span, sawtooth greenhouses
    • Kacira, M., Short, T. H. & Stowell, R. R. (1998) A CFD evaluation of naturally ventilated, multi-span, sawtooth greenhouses. Trans. ASAE, 41(3), 833-836.
    • (1998) Trans. ASAE , vol.41 , Issue.3 , pp. 833-836
    • Kacira, M.1    Short, T.H.2    Stowell, R.R.3
  • 12
    • 0034190626 scopus 로고    scopus 로고
    • Two-dimensional numerical simulation of natural ventilation in a multi-span greenhouse
    • Lee, I. & Short, T. H. (2000) Two-dimensional numerical simulation of natural ventilation in a multi-span greenhouse. Trans. ASAE, 43(3), 745-753.
    • (2000) Trans. ASAE , vol.43 , Issue.3 , pp. 745-753
    • Lee, I.1    Short, T.H.2
  • 13
    • 0034816510 scopus 로고    scopus 로고
    • Verification of computational fluid dynamic temperature simulations in a full-scale naturally ventilated greenhouse
    • Lee, I. & Short T. H. (2001) Verification of computational fluid dynamic temperature simulations in a full-scale naturally ventilated greenhouse. Trans. ASAE, 44(1), 119-127.
    • (2001) Trans. ASAE , vol.44 , Issue.1 , pp. 119-127
    • Lee, I.1    Short, T.H.2
  • 14
    • 0030952077 scopus 로고    scopus 로고
    • Analysis of the efficiency of greenhouse ventilation using computational fluid dynamics
    • Mistriotis, A. et al. (1997) Analysis of the efficiency of greenhouse ventilation using computational fluid dynamics. Agric. For. Meteorol., 85, 217-228.
    • (1997) Agric. For. Meteorol , vol.85 , pp. 217-228
    • Mistriotis, A.1
  • 15
    • 0019621417 scopus 로고
    • A calculation procedure for two-dimensional elliptic situations
    • Patankar, S. V. (1981) A calculation procedure for two-dimensional elliptic situations. Numer. Heat Transfer, 4(4), 409-425.
    • (1981) Numer. Heat Transfer , vol.4 , Issue.4 , pp. 409-425
    • Patankar, S.V.1
  • 16
    • 0000363327 scopus 로고
    • Wind tunnel testing on airflow and temperature distribution of a naturally ventilated greenhouse
    • Sase, S., Takakura, T. & Nara, M. (1984) Wind tunnel testing on airflow and temperature distribution of a naturally ventilated greenhouse. Acta Hortic., 148, 329-336.
    • (1984) Acta Hortic , vol.148 , pp. 329-336
    • Sase, S.1    Takakura, T.2    Nara, M.3
  • 17
    • 0003471874 scopus 로고    scopus 로고
    • Selecting the greenhouse structure your crop needs
    • July
    • Short, T. H. (1996) Selecting the greenhouse structure your crop needs. GrowerTalks, Summer Issue, July, 8-9.
    • (1996) GrowerTalks, Summer Issue , pp. 8-9
    • Short, T.H.1
  • 18
    • 36749045306 scopus 로고    scopus 로고
    • Development of CFD model for estimation of cooling effect of fog cooling system in greenhouse
    • Yu, I. H. (2002) Development of CFD model for estimation of cooling effect of fog cooling system in greenhouse. J. Bio-environ. Control, 11(2), 93-100.
    • (2002) J. Bio-environ. Control , vol.11 , Issue.2 , pp. 93-100
    • Yu, I.H.1