메뉴 건너뛰기




Volumn 34, Issue 12, 2007, Pages 4609-4611

The x-ray light valve: A low-cost digital radiographic imaging system

Author keywords

[No Author keywords available]

Indexed keywords

COSTS;

EID: 36649023493     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2799490     Document Type: Article
Times cited : (3)

References (16)
  • 1
    • 0000899259 scopus 로고    scopus 로고
    • Flat panel detectors for digital radiography
    • edited by J.Beutel, H.Kundel, and R. L.Van Metter (SPIE, Bellingham, 2000), p
    • J. A. Rowlands and J. Yorkston, " Flat panel detectors for digital radiography., " in Handbook of Medical Imaging, Vol. 1 Physics and Psychophysics, edited by, J. Beutel,,, H. Kundel,, and, R. L. Van Metter, (SPIE, Bellingham, 2000), pp. 223-328.
    • Handbook of Medical Imaging, Vol. 1 Physics and Psychophysics , pp. 223-328
    • Rowlands, J.A.1    Yorkston, J.2
  • 2
    • 0037038876 scopus 로고    scopus 로고
    • Physics of computed radiography
    • J. A. Rowlands, " Physics of computed radiography., " Phys. Med. Biol. 47, R123-R166 (2002).
    • (2002) Phys. Med. Biol. , vol.47
    • Rowlands, J.A.1
  • 3
    • 0031029041 scopus 로고    scopus 로고
    • X-ray detectors for digital radiology
    • M. J. Yaffe and J. A. Rowlands, " X-ray detectors for digital radiology., " Phys. Med. Biol. 42, 1-39 (1997).
    • (1997) Phys. Med. Biol. , vol.42 , pp. 1-39
    • Yaffe, M.J.1    Rowlands, J.A.2
  • 4
    • 0027868292 scopus 로고
    • High resolution computed radiography by scanned luminescent toner radiography
    • J. W. May and A. R. Lubinski, " High resolution computed radiography by scanned luminescent toner radiography., " Proc. SPIE 1896, 292-312 (1993).
    • (1993) Proc. SPIE , vol.1896 , pp. 292-312
    • May, J.W.1    Lubinski, A.R.2
  • 6
    • 0016509344 scopus 로고
    • A new real time non-coherent to coherent light image converter-The hybrid field effect liquid crystal light valve
    • J. Grinberg, A. Jacobson, W. Bleha, L. Miller, L. Fraas, D. Boswell, and G. A. Myer, " A new real time non-coherent to coherent light image converter-The hybrid field effect liquid crystal light valve., " Opt. Eng. 14, 217-225 (1975).
    • (1975) Opt. Eng. , vol.14 , pp. 217-225
    • Grinberg, J.1    Jacobson, A.2    Bleha, W.3    Miller, L.4    Fraas, L.5    Boswell, D.6    Myer, G.A.7
  • 7
    • 0001003944 scopus 로고
    • Photoaddressed liquid crystal spatial light modulators
    • D. Armitage, J. I. Thackara, and W. D. Eades, " Photoaddressed liquid crystal spatial light modulators., " Appl. Opt. 28, 4763-4771 (1989).
    • (1989) Appl. Opt. , vol.28 , pp. 4763-4771
    • Armitage, D.1    Thackara, J.I.2    Eades, W.D.3
  • 8
    • 0015710368 scopus 로고
    • Xeroradiography
    • J. W. Boag, " Xeroradiography., " Phys. Med. Biol. 18, 3-37 (1973).
    • (1973) Phys. Med. Biol. , vol.18 , pp. 3-37
    • Boag, J.W.1
  • 11
    • 0028784806 scopus 로고
    • X-ray imaging using amorphous selenium: Feasibility of a flat panel self-scanned detector for digital radiology
    • W. Zhao and J. A. Rowlands, " X-ray imaging using amorphous selenium: Feasibility of a flat panel self-scanned detector for digital radiology., " Med. Phys. 22, 1595-1604 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1595-1604
    • Zhao, W.1    Rowlands, J.A.2
  • 12
    • 0029459059 scopus 로고
    • Amorphous selenium liquid crystal light valve for x-ray imaging
    • edited by R. L.Van Metter and J.Beutel
    • P. K. Rieppo, B. Bahadur, and J. A. Rowlands, " Amorphous selenium liquid crystal light valve for x-ray imaging., " in Physics of Medical Imaging, edited by, R. L. Van Metter, and, J. Beutel,, Proc. SPIE 2432, 228-236 (1995).
    • (1995) Proc. SPIE , vol.2432 , pp. 228-236
    • Rieppo, P.K.1    Bahadur, B.2    Rowlands, J.A.3
  • 14
    • 0030767980 scopus 로고    scopus 로고
    • X-ray imaging using amorphous selenium: Theoretical feasibility of the liquid crystal light valve for radiology
    • P. K. Rieppo and J. A. Rowlands, " X-ray imaging using amorphous selenium: Theoretical feasibility of the liquid crystal light valve for radiology., " Med. Phys. 24, 1279-1292 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1279-1292
    • Rieppo, P.K.1    Rowlands, J.A.2
  • 15
    • 0028941060 scopus 로고
    • X-ray imaging using amorphous selenium: Inherent spatial resolution
    • W. Que and J. A. Rowlands, " X-ray imaging using amorphous selenium: Inherent spatial resolution., " Med. Phys. 22, 365-374 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 365-374
    • Que, W.1    Rowlands, J.A.2
  • 16
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using and edge test device
    • E. Samei, M. J. Flynn, and D. A. Reinmann, " A method for measuring the presampled MTF of digital radiographic systems using and edge test device., " Med. Phys. 25, 102-113 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2    Reinmann, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.