메뉴 건너뛰기




Volumn 2, Issue 4, 2007, Pages 191-196

Acrylic-based hydrogel phantom for in vitro ultrasound contrast agent characterization

Author keywords

Biomimetics; Hydrogels; Medical devices; Photo initiator; Stereolithography apparatus

Indexed keywords


EID: 36549068165     PISSN: 17452759     EISSN: 17452767     Source Type: Journal    
DOI: 10.1080/17452750701747070     Document Type: Conference Paper
Times cited : (3)

References (14)
  • 1
    • 0035062141 scopus 로고    scopus 로고
    • A real vessel phantom for flow imaging: 3-D Doppler ultrasound of steady flow
    • Dabrowski, W., Dunmore-Buyze, J., Cardinal, H.N. and Fenster, A., A real vessel phantom for flow imaging: 3-D Doppler ultrasound of steady flow, Ultrasound Med. Biol., 2001, 27 (1), 135-141.
    • (2001) Ultrasound Med. Biol , vol.27 , Issue.1 , pp. 135-141
    • Dabrowski, W.1    Dunmore-Buyze, J.2    Cardinal, H.N.3    Fenster, A.4
  • 2
    • 25444527941 scopus 로고    scopus 로고
    • Silica moulds built by stereolithography
    • Esposito, Corcione C., et al., Silica moulds built by stereolithography, J. Mater. Sci., 2005, 40, 1-6.
    • (2005) J. Mater. Sci , vol.40 , pp. 1-6
    • Esposito, C.C.1
  • 3
    • 33746605202 scopus 로고    scopus 로고
    • Free form fabrication of silica moulds for aluminium casting by stereolithography
    • Esposito, Corcione C., et al., Free form fabrication of silica moulds for aluminium casting by stereolithography, J. Rapid Prototyping, 2006, 12 (4), 184-188.
    • (2006) J. Rapid Prototyping , vol.12 , Issue.4 , pp. 184-188
    • Esposito, C.C.1
  • 5
    • 0035124681 scopus 로고    scopus 로고
    • Stereolithography of ceramic suspensions
    • Greco, A., Licciulli, A. and Maffezzoli, A., Stereolithography of ceramic suspensions, J. Mater. Sci, 2001, 36, 99-105.
    • (2001) J. Mater. Sci , vol.36 , pp. 99-105
    • Greco, A.1    Licciulli, A.2    Maffezzoli, A.3
  • 6
    • 9544252180 scopus 로고    scopus 로고
    • Comparative study of Polyacrylamid gels and thermo luminescent dosimeters used in external radiotherapy
    • Guillerminet, C., et al., Comparative study of Polyacrylamid gels and thermo luminescent dosimeters used in external radiotherapy, Radiation Measurements, 2005, 39, 39-42.
    • (2005) Radiation Measurements , vol.39 , pp. 39-42
    • Guillerminet, C.1
  • 7
    • 17844400605 scopus 로고    scopus 로고
    • Laser stereolitography of ZrO2 toughened A1203
    • Licciulli, A., et al., Laser stereolitography of ZrO2 toughened A1203, J. Eur. Ceramic Soc., 2005, 25, 1581-1589.
    • (2005) J. Eur. Ceramic Soc , vol.25 , pp. 1581-1589
    • Licciulli, A.1
  • 8
    • 13844272654 scopus 로고    scopus 로고
    • Ultrasonic monitoring of the network formation in superabsorbent cellulose based hydrogels
    • Lionetto, F., et al., Ultrasonic monitoring of the network formation in superabsorbent cellulose based hydrogels, Polymer, 2005, 46 (6), 1796-1803.
    • (2005) Polymer , vol.46 , Issue.6 , pp. 1796-1803
    • Lionetto, F.1
  • 10
    • 0030964904 scopus 로고    scopus 로고
    • Tissue equivalent vessel phantoms for intravascular ultrasound
    • Ryan, L.K. and Foster, F.S., Tissue equivalent vessel phantoms for intravascular ultrasound. Ulrasound Med Biol., 1997, 23 (2), 261-273.
    • (1997) Ulrasound Med Biol , vol.23 , Issue.2 , pp. 261-273
    • Ryan, L.K.1    Foster, F.S.2
  • 11
    • 0036082485 scopus 로고    scopus 로고
    • On the design of a capillary flow phantom for the evaluation of ultrasound contrast agents at very low flow velocities
    • Veltmann, C., et al., On the design of a capillary flow phantom for the evaluation of ultrasound contrast agents at very low flow velocities, Ultrasound Med. Biol., 2002, 28 (5), 625-634.
    • (2002) Ultrasound Med. Biol , vol.28 , Issue.5 , pp. 625-634
    • Veltmann, C.1
  • 12
    • 36549017921 scopus 로고    scopus 로고
    • Product development for Chinese calligraphy using reverse engineering and rapid prototyping
    • Wang et al., Product development for Chinese calligraphy using reverse engineering and rapid prototyping, Virt. Phys. Prototyping, 2006, 1(4), 259-269.
    • (2006) Virt. Phys. Prototyping , vol.1 , Issue.4 , pp. 259-269
    • Wang1
  • 13
    • 33845867448 scopus 로고    scopus 로고
    • The challenges in creating reference maps for verification of ultrasound images
    • Wilhjelm, J.E., et al., The challenges in creating reference maps for verification of ultrasound images, Ultrasonics, 2005, 44, 141-146.
    • (2005) Ultrasonics , vol.44 , pp. 141-146
    • Wilhjelm, J.E.1
  • 14
    • 0035060321 scopus 로고    scopus 로고
    • Dynamics of bubble oscillation in constrained media and mechanism of vessel rupture in swl
    • Zhong, P., Zhou, Y. and Zhu, S., Dynamics of bubble oscillation in constrained media and mechanism of vessel rupture in swl, Ultrasound Med. Biol., 2001, 27 (1), 83-88.
    • (2001) Ultrasound Med. Biol , vol.27 , Issue.1 , pp. 83-88
    • Zhong, P.1    Zhou, Y.2    Zhu, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.