Central venous catheter infusions: A laboratory model shows large differences in drug delivery dynamics related to catheter dead volume

Author keywords

Central venous catheter; Drug infusion, dead volume; Medication safety

Indexed keywords

DRUG CARRIER; METHYLENE BLUE;

EID: 36448996189     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.CCM.0000295587.04882.4F     Document Type: Article
Times cited : (41)

References (12)
  • 1
    • 0022226502 scopus 로고
    • Factors affecting drug delivery from a syringe-pump infusion set
    • Geater RE, Leff RD, Roberts RJ: Factors affecting drug delivery from a syringe-pump infusion set. Am J Hosp Pharm 1985; 42:2510-2513
    • (1985) Am J Hosp Pharm , vol.42 , pp. 2510-2513
    • Geater, R.E.1    Leff, R.D.2    Roberts, R.J.3
  • 2
    • 0023684376 scopus 로고
    • Influence of physical characteristics of intravenous systems on drug delivery
    • Kubajak CA, Leff RD, Roberts RJ: Influence of physical characteristics of intravenous systems on drug delivery. Dev Pharmacol Ther 1988; 11:189-195
    • (1988) Dev Pharmacol Ther , vol.11 , pp. 189-195
    • Kubajak, C.A.1    Leff, R.D.2    Roberts, R.J.3
  • 3
    • 15544389982 scopus 로고    scopus 로고
    • The impact of carrier flow rate and infusion set dead-volume on the dynamics of intravenous drug delivery
    • Lovich MA, Doles J, Peterfreund RA: The impact of carrier flow rate and infusion set dead-volume on the dynamics of intravenous drug delivery. Anesth Analg 2005; 100:1048-1055
    • (2005) Anesth Analg , vol.100 , pp. 1048-1055
    • Lovich, M.A.1    Doles, J.2    Peterfreund, R.A.3
  • 4
    • 33645504101 scopus 로고    scopus 로고
    • The delivery of drugs to patients by continuous intravenous infusion: Modeling predicts potential dose fluctuations depending on flow rates and infusion system dead volume
    • Lovich MA, Kinnealley ME, Sims NM, et al: The delivery of drugs to patients by continuous intravenous infusion: Modeling predicts potential dose fluctuations depending on flow rates and infusion system dead volume. Anesth Analg 2006; 102:1147-1153
    • (2006) Anesth Analg , vol.102 , pp. 1147-1153
    • Lovich, M.A.1    Kinnealley, M.E.2    Sims, N.M.3
  • 5
    • 0035723595 scopus 로고    scopus 로고
    • Start-up delays of infusion syringe pumps
    • Neff T, Fischer J, Fehr S, et al: Start-up delays of infusion syringe pumps. Paediatr Anaesth 2001; 11:561-565
    • (2001) Paediatr Anaesth , vol.11 , pp. 561-565
    • Neff, T.1    Fischer, J.2    Fehr, S.3
  • 6
    • 0028044712 scopus 로고
    • Syringe pumps for infusion of vasoactive drugs: Mechanical idiosyncrasies and recommended operating procedures
    • Rooke GA, Bowdle TA: Syringe pumps for infusion of vasoactive drugs: Mechanical idiosyncrasies and recommended operating procedures. Anesth Analg 1994; 78:150-156
    • (1994) Anesth Analg , vol.78 , pp. 150-156
    • Rooke, G.A.1    Bowdle, T.A.2
  • 7
    • 0031795356 scopus 로고    scopus 로고
    • Variations in the composition of spinal anesthetic solutions: The effects of drug addition order and preparation methods
    • Dull RO, Peterfreund RA: Variations in the composition of spinal anesthetic solutions: The effects of drug addition order and preparation methods. Anesth Analg 1998; 87:1326-1330
    • (1998) Anesth Analg , vol.87 , pp. 1326-1330
    • Dull, R.O.1    Peterfreund, R.A.2
  • 8
    • 0022481818 scopus 로고
    • Altered drug infusion rates during syringe-pump infusion
    • Leff RD, Holstad SG, Kubajak CA, et al: Altered drug infusion rates during syringe-pump infusion. Am J Hosp Pharm 1986; 43:2241-2242
    • (1986) Am J Hosp Pharm , vol.43 , pp. 2241-2242
    • Leff, R.D.1    Holstad, S.G.2    Kubajak, C.A.3
  • 9
    • 0032782615 scopus 로고    scopus 로고
    • Imaging of adenosine bolus transit following intravenous administration: Insights into antiarrhythmic efficacy
    • Ng GA, Martin W, Rankin AC: Imaging of adenosine bolus transit following intravenous administration: Insights into antiarrhythmic efficacy. Heart 1999; 82:163-169
    • (1999) Heart , vol.82 , pp. 163-169
    • GA, N.1    Martin, W.2    Rankin, A.C.3
  • 10
    • 0026656229 scopus 로고
    • The influence of arm position and cardiac output on bolus clearance from the arm
    • McLintic AJ, Martin W, Tweddel AC: The influence of arm position and cardiac output on bolus clearance from the arm. Anaesthesia 1992; 47:838-841
    • (1992) Anaesthesia , vol.47 , pp. 838-841
    • McLintic, A.J.1    Martin, W.2    Tweddel, A.C.3
  • 11
    • 0242500741 scopus 로고    scopus 로고
    • Analysis of cardiopulmonary transit times at contrast material-enhanced MR imaging in patients with heart disease
    • Francois CJ, Shors SM, Bonow RO, et al: Analysis of cardiopulmonary transit times at contrast material-enhanced MR imaging in patients with heart disease. Radiology 2003; 227:447-452
    • (2003) Radiology , vol.227 , pp. 447-452
    • Francois, C.J.1    Shors, S.M.2    Bonow, R.O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.