메뉴 건너뛰기




Volumn 45, Issue 10, 2007, Pages 664-670

Capillary flow technology with multi-dimensional gas chromatography for trace analysis of oxygenated compounds in complex hydrocarbon matrices

Author keywords

[No Author keywords available]

Indexed keywords


EID: 36448993000     PISSN: 00219665     EISSN: None     Source Type: Journal    
DOI: 10.1093/chromsci/45.10.664     Document Type: Article
Times cited : (19)

References (14)
  • 1
    • 33744774686 scopus 로고    scopus 로고
    • Stacked injection with low thermal mass gas chromatography for ppb level detection of oxygenated compounds in hydrocarbon
    • J. Luong, R. Gras, H. Cortes, and R. Mustacich. Stacked injection with low thermal mass gas chromatography for ppb level detection of oxygenated compounds in hydrocarbon. J. Chromatogr. Sci. 44(4): 219-226 (2006).
    • (2006) J. Chromatogr. Sci , vol.44 , Issue.4 , pp. 219-226
    • Luong, J.1    Gras, R.2    Cortes, H.3    Mustacich, R.4
  • 2
    • 85036969772 scopus 로고    scopus 로고
    • ASTM. Standard Test Method for Determination of Methanol in Crude Oils by Multidimensional Gas Chromatography. Method # D7059-4E1, ASTM International, West Conshohocken, PA, USA. http://enterprise.astm.org/REDLINE_PAGES/D7059.htm, accessed date: July 8, 2007.
    • ASTM. Standard Test Method for Determination of Methanol in Crude Oils by Multidimensional Gas Chromatography. Method # D7059-4E1, ASTM International, West Conshohocken, PA, USA. http://enterprise.astm.org/REDLINE_PAGES/D7059.htm, accessed date: July 8, 2007.
  • 3
    • 0345936769 scopus 로고
    • Multidimensional Chromatography: Techniques and Applications
    • CRC Press, Marcel Dekker, Inc, New York, USA
    • H. Cortes. Multidimensional Chromatography: Techniques and Applications. Chromatographic Science Series, Volume 50. CRC Press, Marcel Dekker, Inc., New York, USA, 1990, pp. 1-26, 75-189.
    • (1990) Chromatographic Science Series , vol.50
    • Cortes, H.1
  • 4
    • 84986522852 scopus 로고
    • Concepts and comparisons in multi-dimensional chromatography
    • J.C. Giddings. Concepts and comparisons in multi-dimensional chromatography. J. High Resolut. Chromatogr. 10: 319-323, 1987.
    • (1987) J. High Resolut. Chromatogr , vol.10 , pp. 319-323
    • Giddings, J.C.1
  • 5
    • 17444436399 scopus 로고    scopus 로고
    • Comprehensive two-dimensional gas chromatography: A powerful and versatile analytical tool
    • J. Dalluge and J. Beens. Comprehensive two-dimensional gas chromatography: a powerful and versatile analytical tool. J. Chromatogr., A 1000: 69-108 (2003)
    • (2003) J. Chromatogr., A , vol.1000 , pp. 69-108
    • Dalluge, J.1    Beens, J.2
  • 7
    • 0012156155 scopus 로고    scopus 로고
    • Elsevier Science B.V, Amsterdam, The Netherlands
    • C. Poole. The Essence of Chromatography. Elsevier Science B.V., Amsterdam, The Netherlands, 2003, pp. 219-223.
    • (2003) The Essence of Chromatography , pp. 219-223
    • Poole, C.1
  • 8
    • 0003137705 scopus 로고
    • Use of heart-cutting in gas chromatography - a review
    • D.R. Deans. Use of heart-cutting in gas chromatography - a review. J. Chromatogr. 203: 19-28 (1981).
    • (1981) J. Chromatogr , vol.203 , pp. 19-28
    • Deans, D.R.1
  • 9
    • 85037003249 scopus 로고    scopus 로고
    • K. MacNamara and R. Leardi. Developments in 2D GC with heartcutting. LC-GC 16(12a): 14-22 (2003).
    • K. MacNamara and R. Leardi. Developments in 2D GC with heartcutting. LC-GC 16(12a): 14-22 (2003).
  • 10
    • 36448974763 scopus 로고    scopus 로고
    • 2-D analysis of biodiesel using capillary flow technology deans switch. Agilent Publication 07-19
    • Chicago, March
    • J. McCurry and C. Wang. 2-D analysis of biodiesel using capillary flow technology deans switch. Agilent Publication 07-19, Pittsburg Conference, Chicago, March, 2007.
    • (2007) Pittsburg Conference
    • McCurry, J.1    Wang, C.2
  • 12
    • 85037005367 scopus 로고    scopus 로고
    • Agilent Technologies, 7890A GC Product Introduction Brochure, publication number 5989-5929EN, April, 2007
    • Agilent Technologies, 7890A GC Product Introduction Brochure, publication number 5989-5929EN, April, 2007
  • 13
    • 85036993738 scopus 로고    scopus 로고
    • Klee, M., Simplified Backflush Using Agilent 6890C Post Run Command, Agilent Application Note#5989-5111EN
    • Klee, M., "Simplified Backflush Using Agilent 6890C Post Run Command", Agilent Application Note#5989-5111EN
  • 14
    • 0344468228 scopus 로고    scopus 로고
    • Innovations in high-pressure liquid injection technique for gas chromatography: Pressurized liquid injection system
    • J. Luong, R. Gras, and R. Tymko. Innovations in high-pressure liquid injection technique for gas chromatography: pressurized liquid injection system. J. Chromatogr. Sci. 41(10): 550-559 (2003).
    • (2003) J. Chromatogr. Sci , vol.41 , Issue.10 , pp. 550-559
    • Luong, J.1    Gras, R.2    Tymko, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.