메뉴 건너뛰기




Volumn 45, Issue 11, 2007, Pages 1143-1152

Robust border enhancement and detection for measurement of fetal nuchal translucency in ultrasound images

Author keywords

Border detection; Dynamic programming; Edge enhancing filtering; Fetal nuchal translucency; Semi automatic measurement

Indexed keywords

DYNAMIC PROGRAMMING; EDGE DETECTION; MEDICAL IMAGING; THICKNESS MEASUREMENT;

EID: 36448974879     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/s11517-007-0225-7     Document Type: Article
Times cited : (34)

References (19)
  • 1
    • 0036721081 scopus 로고    scopus 로고
    • Real-time speckle reduction and coherence enhancement in ultrasound imaging via nonlinear anisotropic diffusion
    • Abd-Elmoniem KZ, Youssef AM, Kadah YM (2002) Real-time speckle reduction and coherence enhancement in ultrasound imaging via nonlinear anisotropic diffusion. IEEE Trans Biomed Eng 49(9):997-1014
    • (2002) IEEE Trans Biomed Eng , vol.49 , Issue.9 , pp. 997-1014
    • Abd-Elmoniem, K.Z.1    Youssef, A.M.2    Kadah, Y.M.3
  • 2
    • 33644913401 scopus 로고    scopus 로고
    • Technical aspects of nuchal translucency measurement
    • Alfred A (2005) Technical aspects of nuchal translucency measurement. Semin Perinatol 29(6):376-379
    • (2005) Semin Perinatol , vol.29 , Issue.6 , pp. 376-379
    • Alfred, A.1
  • 3
    • 33645939539 scopus 로고    scopus 로고
    • Detection of congenital heart disease in the first trimester of pregnancy
    • Bebbington M, Wilson RD, Johnson MP (2006) Detection of congenital heart disease in the first trimester of pregnancy. Prog Pediatr Cardiol 22(1):3-8
    • (2006) Prog Pediatr Cardiol , vol.22 , Issue.1 , pp. 3-8
    • Bebbington, M.1    Wilson, R.D.2    Johnson, M.P.3
  • 4
    • 0031974123 scopus 로고    scopus 로고
    • Semiautomated ultrasonographic measurement of fetal nuchal translucency using a computer software tool
    • Bernadino F, Cardoso R, Montenegro N, Bernardes J, Marques de Sa J (1998) Semiautomated ultrasonographic measurement of fetal nuchal translucency using a computer software tool. Ultrasound Med Biol 24(1):51-54
    • (1998) Ultrasound Med Biol , vol.24 , Issue.1 , pp. 51-54
    • Bernadino, F.1    Cardoso, R.2    Montenegro, N.3    Bernardes, J.4    Marques de Sa, J.5
  • 5
    • 0036139071 scopus 로고    scopus 로고
    • Using snakes to detect the intimal and adventitial layers of the common carotid artery wall in sonographic images
    • Cheng D, Schmidt-Trucksaess A, Cheng K, Burkhardt H (2002) Using snakes to detect the intimal and adventitial layers of the common carotid artery wall in sonographic images. Comput Methods Programs Biomed 67(1):27-37
    • (2002) Comput Methods Programs Biomed , vol.67 , Issue.1 , pp. 27-37
    • Cheng, D.1    Schmidt-Trucksaess, A.2    Cheng, K.3    Burkhardt, H.4
  • 6
    • 0035354918 scopus 로고    scopus 로고
    • Fast edge-preserving noise reduction for ultrasound images
    • Chinrungrueng C, Suvichakorn A (2001) Fast edge-preserving noise reduction for ultrasound images. IEEE Trans Nucl Sci 48(3):849-854
    • (2001) IEEE Trans Nucl Sci , vol.48 , Issue.3 , pp. 849-854
    • Chinrungrueng, C.1    Suvichakorn, A.2
  • 8
    • 0000815211 scopus 로고
    • A dynamic programming procedure for automated ultrasonic measurement of the carotid artery
    • Gustavsson T, Liang Q, Wendelhag I, Wilkstrand J (1994) A dynamic programming procedure for automated ultrasonic measurement of the carotid artery. IEEE Comput Cardiol, pp 297-300
    • (1994) IEEE Comput Cardiol , pp. 297-300
    • Gustavsson, T.1    Liang, Q.2    Wendelhag, I.3    Wilkstrand, J.4
  • 9
    • 0028790490 scopus 로고
    • Cardiac defects in 1st trimester fetus with trisomy 18
    • Hyett J, Moscosco G, Nicolaides KH (1995) Cardiac defects in 1st trimester fetus with trisomy 18. Fetal Diag Ther 10(6):381-386
    • (1995) Fetal Diag Ther , vol.10 , Issue.6 , pp. 381-386
    • Hyett, J.1    Moscosco, G.2    Nicolaides, K.H.3
  • 10
    • 0033624995 scopus 로고    scopus 로고
    • A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images
    • Liang Q, Wendelhag I, Wilkstrand J, Gustavsson T (2000) A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images. IEEE Trans Med Imaging 19(2):127-142
    • (2000) IEEE Trans Med Imaging , vol.19 , Issue.2 , pp. 127-142
    • Liang, Q.1    Wendelhag, I.2    Wilkstrand, J.3    Gustavsson, T.4
  • 13
    • 0025465145 scopus 로고
    • Scale space and edge detection using anisotropic diffusion
    • Perona P, Malik J (1990) Scale space and edge detection using anisotropic diffusion. IEEE Trans Pattern Anal Mach Intell 12(7):629-639
    • (1990) IEEE Trans Pattern Anal Mach Intell , vol.12 , Issue.7 , pp. 629-639
    • Perona, P.1    Malik, J.2
  • 14
    • 0032146382 scopus 로고    scopus 로고
    • UK multicentre project on assessment of risk of trisomy 21 by maternal age and fetal nuchal translucency thickness at 10-14 weeks of gestation
    • Snijders RJ, Noble P, Sebire N, Souka A, Nicolaides KH (1998) UK multicentre project on assessment of risk of trisomy 21 by maternal age and fetal nuchal translucency thickness at 10-14 weeks of gestation. Lancet 352(9125):343-346
    • (1998) Lancet , vol.352 , Issue.9125 , pp. 343-346
    • Snijders, R.J.1    Noble, P.2    Sebire, N.3    Souka, A.4    Nicolaides, K.H.5
  • 15
    • 0034920539 scopus 로고    scopus 로고
    • Outcome of pregnancy in chromosomally normal fetuses with increased nuchal translucency in the first trimester
    • Souka AP, Krampl E, Bakalis S, Heath V, Nicolaides KH (2001) Outcome of pregnancy in chromosomally normal fetuses with increased nuchal translucency in the first trimester. Ultrasound Obstet Gynecol 18(1):9-17
    • (2001) Ultrasound Obstet Gynecol , vol.18 , Issue.1 , pp. 9-17
    • Souka, A.P.1    Krampl, E.2    Bakalis, S.3    Heath, V.4    Nicolaides, K.H.5
  • 16
    • 0032666007 scopus 로고    scopus 로고
    • Coherence-enhancing diffusion filtering
    • Weickert J (1999) Coherence-enhancing diffusion filtering. Int J Comput Vis 31(2-3):111-127
    • (1999) Int J Comput Vis , vol.31 , Issue.2-3 , pp. 111-127
    • Weickert, J.1
  • 17
    • 0030710511 scopus 로고    scopus 로고
    • A new automated computerized analyzing system simplifies readings and reduces the variability in ultrasound measurement of intima-media thickness
    • Wendelhag I, Liang Q, Gustavson T, Wilkstrand J (1997) A new automated computerized analyzing system simplifies readings and reduces the variability in ultrasound measurement of intima-media thickness. Stroke 28(11):2195-2200
    • (1997) Stroke , vol.28 , Issue.11 , pp. 2195-2200
    • Wendelhag, I.1    Liang, Q.2    Gustavson, T.3    Wilkstrand, J.4
  • 18
    • 0026741340 scopus 로고
    • A fast algorithm for active contours and curvature estimation
    • Williams DJ, Shah M (1992) A fast algorithm for active contours and curvature estimation. CVGIP Image Underst 55(1):14-26
    • (1992) CVGIP Image Underst , vol.55 , Issue.1 , pp. 14-26
    • Williams, D.J.1    Shah, M.2
  • 19
    • 0032797668 scopus 로고    scopus 로고
    • Early diagnosis of major cardiac defects in chromosomally normal fetuses with increased nuchal translucency
    • Zosmer N, Souter VL, Chan CS, Huggon IC, Nicolaides KH (1999) Early diagnosis of major cardiac defects in chromosomally normal fetuses with increased nuchal translucency. Br J Obstet Gynaecol 106(8):829-833
    • (1999) Br J Obstet Gynaecol , vol.106 , Issue.8 , pp. 829-833
    • Zosmer, N.1    Souter, V.L.2    Chan, C.S.3    Huggon, I.C.4    Nicolaides, K.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.