메뉴 건너뛰기




Volumn 189, Issue 6, 2007, Pages 1457-1463

Quality assessment for CT colonography: Validation of automated measurement of colonic distention and residual fluid

Author keywords

Colon; Colonography; CT; Quality; Virtual colonoscopy

Indexed keywords

ADULT; AGED; ARTICLE; AUTOMATION; CLINICAL ARTICLE; CLINICAL ASSESSMENT; COMPUTED TOMOGRAPHIC COLONOGRAPHY; COMPUTER PROGRAM; FEMALE; GASTROINTESTINAL TRACT; HUMAN; IMAGE ANALYSIS; INTESTINE DISTENSION; MALE; PRIORITY JOURNAL; QUALITY CONTROL; RADIOLOGIST; SCORING SYSTEM; VALIDITY;

EID: 36448973048     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/AJR.07.2327     Document Type: Article
Times cited : (13)

References (18)
  • 1
    • 0345690179 scopus 로고    scopus 로고
    • Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults
    • Pickhardt PJ, Choi JR, Hwang I, et al. Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults. N Engl J Med 2003; 349:2191-2200
    • (2003) N Engl J Med , vol.349 , pp. 2191-2200
    • Pickhardt, P.J.1    Choi, J.R.2    Hwang, I.3
  • 2
    • 11144358036 scopus 로고    scopus 로고
    • Computed tomographic colonography (virtual colonoscopy): A multicenter comparison with standard colonoscopy for detection of colorectal neoplasia
    • Cotton PB, Durkalski VL, Benoit PC, et al. Computed tomographic colonography (virtual colonoscopy): a multicenter comparison with standard colonoscopy for detection of colorectal neoplasia. JAMA 2004; 291:1713-1719
    • (2004) JAMA , vol.291 , pp. 1713-1719
    • Cotton, P.B.1    Durkalski, V.L.2    Benoit, P.C.3
  • 4
    • 0036081920 scopus 로고    scopus 로고
    • Quality in the technical performance of colonoscopy and the continuous quality improvement process for colonoscopy: Recommendations of the U.S. Multi-Society Task Force on Colorectal Cancer
    • Rex DK, Bond JH, Winawer S, et al. Quality in the technical performance of colonoscopy and the continuous quality improvement process for colonoscopy: recommendations of the U.S. Multi-Society Task Force on Colorectal Cancer. Am J Gastroenterol 2002; 97:1296-1308
    • (2002) Am J Gastroenterol , vol.97 , pp. 1296-1308
    • Rex, D.K.1    Bond, J.H.2    Winawer, S.3
  • 5
    • 0035138187 scopus 로고    scopus 로고
    • Effect of different bowel preparations on residual fluid at CT colonography
    • Macari M, Lavelle M, Pedrosa I, et al. Effect of different bowel preparations on residual fluid at CT colonography. Radiology 2001; 218:274-277
    • (2001) Radiology , vol.218 , pp. 274-277
    • Macari, M.1    Lavelle, M.2    Pedrosa, I.3
  • 6
    • 33644841724 scopus 로고    scopus 로고
    • Automated insufflation of carbon dioxide for MDCT colonography: Distension and patient experience compared with manual insufflation
    • Burling D, Taylor SA, Halligan S, et al. Automated insufflation of carbon dioxide for MDCT colonography: distension and patient experience compared with manual insufflation. AJR 2006; 186:96-103
    • (2006) AJR , vol.186 , pp. 96-103
    • Burling, D.1    Taylor, S.A.2    Halligan, S.3
  • 7
    • 0032965930 scopus 로고    scopus 로고
    • The usefulness of glucagon hydrochloride for colonic distention in CT colonography
    • Yee J, Hung RK, Akerkar GA, Wall SD. The usefulness of glucagon hydrochloride for colonic distention in CT colonography. AJR 1999; 173:169-172
    • (1999) AJR , vol.173 , pp. 169-172
    • Yee, J.1    Hung, R.K.2    Akerkar, G.A.3    Wall, S.D.4
  • 8
    • 33745493238 scopus 로고    scopus 로고
    • Patient-controlled room air insufflation versus automated carbon dioxide delivery for CT colonography
    • Shinners TJ, Pickhardt PJ, Taylor AJ, Jones DA, Olsen CH. Patient-controlled room air insufflation versus automated carbon dioxide delivery for CT colonography. AJR 2006; 186:1491-1496
    • (2006) AJR , vol.186 , pp. 1491-1496
    • Shinners, T.J.1    Pickhardt, P.J.2    Taylor, A.J.3    Jones, D.A.4    Olsen, C.H.5
  • 9
    • 0141518442 scopus 로고    scopus 로고
    • Optimizing colonic distention for multi-detector row CT colonography: Effect of hyoscine butylbromide and rectal balloon catheter
    • Taylor SA, Halligan S, Goh V, et al. Optimizing colonic distention for multi-detector row CT colonography: effect of hyoscine butylbromide and rectal balloon catheter. Radiology 2003; 229:99-108
    • (2003) Radiology , vol.229 , pp. 99-108
    • Taylor, S.A.1    Halligan, S.2    Goh, V.3
  • 10
    • 33646161486 scopus 로고    scopus 로고
    • Advice for optimizing colonic distention and minimizing risk of perforation during CT colonography
    • Dachman AH. Advice for optimizing colonic distention and minimizing risk of perforation during CT colonography. Radiology 2006; 239:317-321
    • (2006) Radiology , vol.239 , pp. 317-321
    • Dachman, A.H.1
  • 11
    • 0036156493 scopus 로고    scopus 로고
    • Quantification of distention in CT colonography: Development and validation of three computer algorithms
    • Hung PW, Paik DS, Napel S, et al. Quantification of distention in CT colonography: development and validation of three computer algorithms. Radiology 2002; 222:543-554
    • (2002) Radiology , vol.222 , pp. 543-554
    • Hung, P.W.1    Paik, D.S.2    Napel, S.3
  • 13
    • 0242268001 scopus 로고    scopus 로고
    • Automated centerline for computed tomography colonography
    • Iordanescu G, Summers RM. Automated centerline for computed tomography colonography. Acad Radiol 2003; 10:1291-1301
    • (2003) Acad Radiol , vol.10 , pp. 1291-1301
    • Iordanescu, G.1    Summers, R.M.2
  • 15
    • 0033065857 scopus 로고    scopus 로고
    • CT colonography: Value of scanning in both the supine and prone positions
    • Chen SC, Lu DS, Hecht JR, Kadell BM. CT colonography: value of scanning in both the supine and prone positions. AJR 1999; 172:595-599
    • (1999) AJR , vol.172 , pp. 595-599
    • Chen, S.C.1    Lu, D.S.2    Hecht, J.R.3    Kadell, B.M.4
  • 16
    • 20244374240 scopus 로고    scopus 로고
    • False-negative results at multi-detector row CT colonography: Multivariate analysis of causes for missed lesions
    • Park SH, Ha HK, Kim MJ, et al. False-negative results at multi-detector row CT colonography: multivariate analysis of causes for missed lesions. Radiology 2005; 235:495-502
    • (2005) Radiology , vol.235 , pp. 495-502
    • Park, S.H.1    Ha, H.K.2    Kim, M.J.3
  • 18
    • 2542500667 scopus 로고    scopus 로고
    • Supine/left decubitus scanning: A valuable alternative to supine/prone scanning in CT colonography
    • Gryspeerdt SS, Herman MJ, Baekelandt MA, van Holsbeeck BG, Lefere PA. Supine/left decubitus scanning: a valuable alternative to supine/prone scanning in CT colonography. Eur Radiol 2004; 14:768-777
    • (2004) Eur Radiol , vol.14 , pp. 768-777
    • Gryspeerdt, S.S.1    Herman, M.J.2    Baekelandt, M.A.3    van Holsbeeck, B.G.4    Lefere, P.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.