메뉴 건너뛰기




Volumn 18, Issue 12, 2007, Pages 2233-2241

A Low-Noise, Wideband Preamplifier for a Fourier-Transform Ion Cyclotron Resonance Mass Spectrometer

Author keywords

[No Author keywords available]

Indexed keywords

AMPLIFIERS (ELECTRONIC); BANDWIDTH; MASS SPECTROMETERS; OPTICAL RESOLVING POWER; SPECTROSCOPIC ANALYSIS;

EID: 36349021257     PISSN: 10440305     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jasms.2007.09.013     Document Type: Article
Times cited : (12)

References (35)
  • 1
    • 0035241690 scopus 로고    scopus 로고
    • Mass Spectrometry in Proteomics
    • [Review]
    • Aebersold R., and Goodlett D.R. Mass Spectrometry in Proteomics. Chem. Rev. 101 (2001) 269-295 [Review]
    • (2001) Chem. Rev. , vol.101 , pp. 269-295
    • Aebersold, R.1    Goodlett, D.R.2
  • 2
    • 0032979179 scopus 로고    scopus 로고
    • Protein Analysis by Mass Spectrometry and Sequence Database Searching: Tools for Cancer Research in the Post-Genomic Era
    • Gygi S.P., Han D.K., Gingras A.C., Sonenberg N., and Aebersold R. Protein Analysis by Mass Spectrometry and Sequence Database Searching: Tools for Cancer Research in the Post-Genomic Era. Electrophoresis 20 (1999) 310-319
    • (1999) Electrophoresis , vol.20 , pp. 310-319
    • Gygi, S.P.1    Han, D.K.2    Gingras, A.C.3    Sonenberg, N.4    Aebersold, R.5
  • 3
    • 0027608882 scopus 로고
    • Use of Mass Spectrometric Molecular Weight Information to Identify Proteins in Sequence Databases
    • Mann M., Hojrup P., and Roepstorff P. Use of Mass Spectrometric Molecular Weight Information to Identify Proteins in Sequence Databases. Biol. Mass Spectrom. 22 (1993) 338-345
    • (1993) Biol. Mass Spectrom. , vol.22 , pp. 338-345
    • Mann, M.1    Hojrup, P.2    Roepstorff, P.3
  • 5
    • 0001268221 scopus 로고
    • Fourier Transform Ion Cyclotron Resonance Spectroscopy
    • Comisarow M.B., and Marshall A.G. Fourier Transform Ion Cyclotron Resonance Spectroscopy. Chem. Phys. Lett. 25 (1974) 282-283
    • (1974) Chem. Phys. Lett. , vol.25 , pp. 282-283
    • Comisarow, M.B.1    Marshall, A.G.2
  • 6
    • 49549153202 scopus 로고
    • Frequency-Sweep Fourier Transform Ion Cyclotron Resonance Spectroscopy
    • Comisarow M.B., and Marshall A.G. Frequency-Sweep Fourier Transform Ion Cyclotron Resonance Spectroscopy. Chem. Phys. Lett. 26 (1974) 489-490
    • (1974) Chem. Phys. Lett. , vol.26 , pp. 489-490
    • Comisarow, M.B.1    Marshall, A.G.2
  • 7
    • 0030461690 scopus 로고    scopus 로고
    • Fourier Transform Mass Spectrometry
    • Amster I.J. Fourier Transform Mass Spectrometry. J. Mass Spectrom. 31 (1996) 1325-1337
    • (1996) J. Mass Spectrom. , vol.31 , pp. 1325-1337
    • Amster, I.J.1
  • 8
    • 0345862096 scopus 로고    scopus 로고
    • A High Pressure Matrix-Assisted Laser Desorption Ion Source for Fourier Transform Mass Spectrometry Designed to Accommodate Large Targets with Diverse Surfaces
    • O'Connor P.B., Budnik B.A., Ivleva V.B., Kaur P., Moyer S.C., Pittman J.L., and Costello C.E. A High Pressure Matrix-Assisted Laser Desorption Ion Source for Fourier Transform Mass Spectrometry Designed to Accommodate Large Targets with Diverse Surfaces. J. Am. Soc. Mass Spectrom. 15 (2004) 128-132
    • (2004) J. Am. Soc. Mass Spectrom. , vol.15 , pp. 128-132
    • O'Connor, P.B.1    Budnik, B.A.2    Ivleva, V.B.3    Kaur, P.4    Moyer, S.C.5    Pittman, J.L.6    Costello, C.E.7
  • 10
    • 0040295109 scopus 로고
    • Signal Modeling for Ion Cyclotron Resonance
    • Comisarow M.B. Signal Modeling for Ion Cyclotron Resonance. J. Chem. Phys. 69 (1978) 4097-4104
    • (1978) J. Chem. Phys. , vol.69 , pp. 4097-4104
    • Comisarow, M.B.1
  • 11
    • 36749105769 scopus 로고
    • Theory of Fourier Transform Ion Cyclotron Resonance Mass Spectroscopy
    • Comisarow M.B., and Marshall A.G. Theory of Fourier Transform Ion Cyclotron Resonance Mass Spectroscopy. J. Chem. Phys. 64 (1976) 110-119
    • (1976) J. Chem. Phys. , vol.64 , pp. 110-119
    • Comisarow, M.B.1    Marshall, A.G.2
  • 12
    • 0001130980 scopus 로고
    • Experimental Determination of the Number of Trapped Ions, Detection Limit, and Dynamic Range in FTICR-MS
    • Limbach P.A., Grosshans P.B., and Marshall A.G. Experimental Determination of the Number of Trapped Ions, Detection Limit, and Dynamic Range in FTICR-MS. Anal. Chem. 65 (1993) 135-140
    • (1993) Anal. Chem. , vol.65 , pp. 135-140
    • Limbach, P.A.1    Grosshans, P.B.2    Marshall, A.G.3
  • 13
    • 2442695484 scopus 로고    scopus 로고
    • Use of Statistical Methods for Estimation of Total Number of Charges in a Mass Spectrometry Experiment
    • Kaur P., and O'Connor P.B. Use of Statistical Methods for Estimation of Total Number of Charges in a Mass Spectrometry Experiment. Anal. Chem. 76 (2004) 2756-2762
    • (2004) Anal. Chem. , vol.76 , pp. 2756-2762
    • Kaur, P.1    O'Connor, P.B.2
  • 14
    • 0033083537 scopus 로고    scopus 로고
    • Routine Part-Per-Million Mass Accuracy for High-Mass Ions: Space-Charge Effects in MALDI FT-ICR
    • Easterling M.L., Mize T.H., and Amster I.J. Routine Part-Per-Million Mass Accuracy for High-Mass Ions: Space-Charge Effects in MALDI FT-ICR. Anal. Chem. 71 (1999) 624-632
    • (1999) Anal. Chem. , vol.71 , pp. 624-632
    • Easterling, M.L.1    Mize, T.H.2    Amster, I.J.3
  • 15
    • 0001053972 scopus 로고
    • Accurate Atomic Mass Measurements from Penning Trap Mass Comparisons of Individual Ions
    • Difilippo F., Natarajan V., Bradley M., Palmer F., and Pritchard D. Accurate Atomic Mass Measurements from Penning Trap Mass Comparisons of Individual Ions. Phys. Scripta 63 (1995) 144-154
    • (1995) Phys. Scripta , vol.63 , pp. 144-154
    • Difilippo, F.1    Natarajan, V.2    Bradley, M.3    Palmer, F.4    Pritchard, D.5
  • 18
    • 0021705942 scopus 로고
    • Space Charge Effects in Fourier Transform Mass Spectrometry. Mass Calibration
    • J.
    • Ledford E.B., Rempel D.L., and Gross M.L. Space Charge Effects in Fourier Transform Mass Spectrometry. Mass Calibration. J. Anal. Chem. 56 (1984) 2744-2748
    • (1984) Anal. Chem. , vol.56 , pp. 2744-2748
    • Ledford, E.B.1    Rempel, D.L.2    Gross, M.L.3
  • 19
    • 14744267430 scopus 로고    scopus 로고
    • Accurate Mass Measurements by Fourier Transform Mass Spectrometry
    • Zhang L.K., Rempel D., Pramanik B.N., and Gross M.L. Accurate Mass Measurements by Fourier Transform Mass Spectrometry. Mass Spectrom. Rev. 24 (2005) 286-309
    • (2005) Mass Spectrom. Rev. , vol.24 , pp. 286-309
    • Zhang, L.K.1    Rempel, D.2    Pramanik, B.N.3    Gross, M.L.4
  • 20
    • 0001196937 scopus 로고
    • Comprehensive Theory of the Fourier Transform Ion Cyclotron Resonance Signal for All Ion Trap Geometries
    • Grosshans P.B., Shields P.J., and Marshall A.G. Comprehensive Theory of the Fourier Transform Ion Cyclotron Resonance Signal for All Ion Trap Geometries. J. Chem. Phys. 94 (1991) 5341-5352
    • (1991) J. Chem. Phys. , vol.94 , pp. 5341-5352
    • Grosshans, P.B.1    Shields, P.J.2    Marshall, A.G.3
  • 22
    • 36849131315 scopus 로고
    • Currents to Conductors Induced by a Moving Point Charge
    • Shockley W. Currents to Conductors Induced by a Moving Point Charge. J. Appl. Phys. 9 (1938) 635-636
    • (1938) J. Appl. Phys. , vol.9 , pp. 635-636
    • Shockley, W.1
  • 23
    • 0037212589 scopus 로고    scopus 로고
    • Space Charge Effects on Mass Accuracy for Multiply Charged Ions in ESI-FTICR
    • Amster I.J., and Kristina T.P. Space Charge Effects on Mass Accuracy for Multiply Charged Ions in ESI-FTICR. Int. J. Mass Spectrom 222 (2003) 351-361
    • (2003) Int. J. Mass Spectrom , vol.222 , pp. 351-361
    • Amster, I.J.1    Kristina, T.P.2
  • 25
    • 0001443498 scopus 로고
    • On a New Action of the Magnet on Electric Currents
    • Edwin H. On a New Action of the Magnet on Electric Currents. Am. J. Math. 2 (1879) 287-292
    • (1879) Am. J. Math. , vol.2 , pp. 287-292
    • Edwin, H.1
  • 26
    • 36149025974 scopus 로고
    • Thermal Agitation of Electricity in Conductors
    • Johnson J.B. Thermal Agitation of Electricity in Conductors. Phy. Rev. 32 (1928) 97-109
    • (1928) Phy. Rev. , vol.32 , pp. 97-109
    • Johnson, J.B.1
  • 27
    • 4344611591 scopus 로고
    • Open Trapped Ion Cell Geometries for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Beu S.C., and Laude D.A.J. Open Trapped Ion Cell Geometries for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Int. J. Mass Spectrom. Ion Processes 112 (1992) 215-230
    • (1992) Int. J. Mass Spectrom. Ion Processes , vol.112 , pp. 215-230
    • Beu, S.C.1    Laude, D.A.J.2
  • 30
    • 84961835646 scopus 로고
    • Über Spontane Stromschwankungen In Verschiedenen Elektrizitätsleitern
    • Schottky W. Über Spontane Stromschwankungen In Verschiedenen Elektrizitätsleitern. Ann. Phys. 57 (1918) 541-568
    • (1918) Ann. Phys. , vol.57 , pp. 541-568
    • Schottky, W.1
  • 31
    • 8744298128 scopus 로고
    • Dependence of the Input Impedance of a Three-Electrode Vacuum Tube upon the Load in the Plate Circuit
    • Miller J.M. Dependence of the Input Impedance of a Three-Electrode Vacuum Tube upon the Load in the Plate Circuit. Scientific Papers of the Bureau of Standards 15 (1920) 367-385
    • (1920) Scientific Papers of the Bureau of Standards , vol.15 , pp. 367-385
    • Miller, J.M.1
  • 32
    • 0034224321 scopus 로고    scopus 로고
    • Noise of the JFET Amplifier
    • Levinzon F.A. Noise of the JFET Amplifier. IEEE T Circuits Syst. 47 (2000) 981-985
    • (2000) IEEE T Circuits Syst. , vol.47 , pp. 981-985
    • Levinzon, F.A.1
  • 34
    • 33751556484 scopus 로고    scopus 로고
    • Design and Implementation of a High Power rf Oscillator on a Printed Circuit Board for Multipole Ion Guides
    • Mathur R., and O'Connor P.B. Design and Implementation of a High Power rf Oscillator on a Printed Circuit Board for Multipole Ion Guides. Rev. Sci. Instrum. 77 (2006) 114101
    • (2006) Rev. Sci. Instrum. , vol.77 , pp. 114101
    • Mathur, R.1    O'Connor, P.B.2