Volumn , Issue , 2007, Pages 2285-2291

Development of a Suture/Ligature training system designed to provide quantitative information of the learning progress of trainees

Author keywords

[No Author keywords available]

Indexed keywords

MEDICAL INTERVENTION; QUANTITATIVE INFORMATION;

EID: 36349005825     PISSN: 10504729     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ROBOT.2007.363660     Document Type: Conference Paper
Times cited : (19)

References (10)
  • 1
    • 36349001387 scopus 로고    scopus 로고
    • K. Nishikawa, Y. Park, M. Aizuddin, K. Yoshinaga, K. Ogura, M. Umezu and A. Takanishi: Development of Carbon Microcoils (CMC) Sensor System with High Sensitivity for Effective Acquisition of Tactile Information, Proceedings of the 2005 IEEE International Conference on Intelligent Robots and Systems, 2005.8W.-K. Chen, Linear Networks and Systems (Book style). Belmont, CA: Wadsworth, 1993, pp. 123-135.
    • K. Nishikawa, Y. Park, M. Aizuddin, K. Yoshinaga, K. Ogura, M. Umezu and A. Takanishi: "Development of Carbon Microcoils (CMC) Sensor System with High Sensitivity for Effective Acquisition of Tactile Information", Proceedings of the 2005 IEEE International Conference on Intelligent Robots and Systems, 2005.8W.-K. Chen, Linear Networks and Systems (Book style). Belmont, CA: Wadsworth, 1993, pp. 123-135.
  • 3
    • 0024240183 scopus 로고    scopus 로고
    • S. Seki: Techniques for better suturing, British Journal of Surgery 75,pp. 1181-1184, 1988.12.
    • S. Seki: "Techniques for better suturing", British Journal of Surgery Vol. 75,pp. 1181-1184, 1988.12.
  • 4
    • 0032861335 scopus 로고    scopus 로고
    • Force controlled and teleoperated endoscopic grasper for minimally invasive surgery- experimental performance evaluation
    • Rosen J., Hannaford B., MacFarlane M.P., Sinanan M.A.: "Force controlled and teleoperated endoscopic grasper for minimally invasive surgery- experimental performance evaluation", In Proc. of the IEEE Trans. Biomed. Engineering, pp.1212-1221, 1999.
    • (1999) In Proc. of the IEEE Trans. Biomed. Engineering , pp. 1212-1221
    • Rosen, J.1    Hannaford, B.2    MacFarlane, M.P.3    Sinanan, M.A.4
  • 5
    • 0033982514 scopus 로고    scopus 로고
    • Effect of intracorporeal-extracorporeal instrument length ratio on endoscopic task performance and surgeon movements
    • Emam TA., Hanna G.B., Kimber C., Dunkley P., Cuschieri A.: "Effect of intracorporeal-extracorporeal instrument length ratio on endoscopic task performance and surgeon movements", Arch. Surg., pp. 62-65, 2000.
    • (2000) Arch. Surg , pp. 62-65
    • Emam, T.A.1    Hanna, G.B.2    Kimber, C.3    Dunkley, P.4    Cuschieri, A.5
  • 6
    • 0032984759 scopus 로고    scopus 로고
    • Measuring and developing suturing technique with a virtual reality surgical simulator
    • O' Toole R.V., Playter R.R., et al.: "Measuring and developing suturing technique with a virtual reality surgical simulator", J. Am. Coll. Surg. Vol. 189, pp. 114-127, 1999.
    • (1999) J. Am. Coll. Surg , vol.189 , pp. 114-127
    • O' Toole, R.V.1    Playter, R.R.2
  • 7
    • 0035032844 scopus 로고    scopus 로고
    • Markov modeling of minimally invasive surgery based on tool/ tissue interaction and force/torque signatures for evaluationg surgical skills
    • Rosen J., Hannaford B., Richards C.G., Sinanan M.N.: "Markov modeling of minimally invasive surgery based on tool/ tissue interaction and force/torque signatures for evaluationg surgical skills", in Proc. of the IEEE Trans. Biomed. Engineering, pp.579-591, 2001.
    • (2001) Proc. of the IEEE Trans. Biomed. Engineering , pp. 579-591
    • Rosen, J.1    Hannaford, B.2    Richards, C.G.3    Sinanan, M.N.4
  • 9
    • 0024694753 scopus 로고
    • Suturing Techniques of Individual Surgeons- Differences in Accuracy and Mechanics
    • S. Seki: "Suturing Techniques of Individual Surgeons- Differences in Accuracy and Mechanics", Japanese Journal of Surgery Vol. 19, pp. 424-431, 1989.
    • (1989) Japanese Journal of Surgery , vol.19 , pp. 424-431
    • Seki, S.1