메뉴 건너뛰기




Volumn , Issue , 2007, Pages 328-331

3D fuzzy adaptive unsupervised Bayesian segmentation for volume determination in pet

Author keywords

Fuzzy; PET; Segmentation; Volume

Indexed keywords

FUZZY C-MEANS (FCM); NOISE MODELING; SPATIAL INFORMATION; UNSUPERVISED BAYESIAN SEGMENTATION;

EID: 36348996558     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISBI.2007.356855     Document Type: Conference Paper
Times cited : (3)

References (14)
  • 2
    • 17644421807 scopus 로고    scopus 로고
    • Effects of ROI definition and reconstruction method on quantitative outcome and applicability in a response monitoring trial
    • N.C. Krak, R. Boellaard et al, Effects of ROI definition and reconstruction method on quantitative outcome and applicability in a response monitoring trial. Eur. J. Nucl. Med. MoI. Im., 32, 294-301, 2005.
    • (2005) Eur. J. Nucl. Med. MoI. Im , vol.32 , pp. 294-301
    • Krak, N.C.1    Boellaard, R.2
  • 3
    • 0031360130 scopus 로고    scopus 로고
    • Automated 3D Segmentation of Respiratory-Gated PET Transmission linages
    • BW. Reutter, GJ. Klein, RH. Huesman, Automated 3D Segmentation of Respiratory-Gated PET Transmission linages, IEEE Trans. Nucl. Sci., 44(6):2473-2476, 1997.
    • (1997) IEEE Trans. Nucl. Sci , vol.44 , Issue.6 , pp. 2473-2476
    • Reutter, B.W.1    Klein, G.J.2    Huesman, R.H.3
  • 4
    • 11844273862 scopus 로고    scopus 로고
    • Automation Segmentation of PET Image for Brain Tumors
    • W. Zhu, T. Jiang, Automation Segmentation of PET Image for Brain Tumors, IEEE NSSC Records, 2003.
    • (2003) IEEE NSSC Records
    • Zhu, W.1    Jiang, T.2
  • 5
    • 33645302410 scopus 로고    scopus 로고
    • A multiresolution image based approach for correction of partial volume effects in emission tomography
    • N. Boussion, M. Hatt, F. Lamare, Y. Bizais, A. Turzo, C. Cheze-Le Rest, D. Visvikis, A multiresolution image based approach for correction of partial volume effects in emission tomography, Phys. in Med. Biol., Vol. 51, pp. 1857-1876, 2006.
    • (2006) Phys. in Med. Biol , vol.51 , pp. 1857-1876
    • Boussion, N.1    Hatt, M.2    Lamare, F.3    Bizais, Y.4    Turzo, A.5    Cheze, C.6    Rest, L.7    Visvikis, D.8
  • 6
  • 7
    • 25444452894 scopus 로고    scopus 로고
    • U. Nestle. S. Kremp. A. Schaet'er-Schuler, C. Sebastian-Welch. D. Hellwig, C. Rübe, C-M. Kirsch, Comparison of Different Methods for Delineation of 18F-FDG PET-Positive Tissue for Target Definition in Radiotherapy of Patients with Non-Small Cell Lung Cancer, J. Nucl. Med., 2005.
    • U. Nestle. S. Kremp. A. Schaet'er-Schuler, C. Sebastian-Welch. D. Hellwig, C. Rübe, C-M. Kirsch, Comparison of Different Methods for Delineation of 18F-FDG PET-Positive Tissue for Target Volume Definition in Radiotherapy of Patients with Non-Small Cell Lung Cancer, J. Nucl. Med., 2005.
  • 8
    • 33750949682 scopus 로고    scopus 로고
    • Modèles de Markov en traitement d'images
    • W. Pieczynski, Modèles de Markov en traitement d'images, Traitement du Signal, Vol. 20, No. 3, pp. 255-277, 2003.
    • (2003) Traitement du Signal , vol.20 , Issue.3 , pp. 255-277
    • Pieczynski, W.1
  • 9
    • 36348996147 scopus 로고    scopus 로고
    • M. Hatt, N. Boussion, F. Lamare, C. Collet, F. Salzenstein, C. Roux, Y. Bizais, C. Cheze-Le Rest, D. Visvikis, Fuzzy versus Hard Hidden Markov Chains Segmentation for Determination and Quantitation in Noisy PET Images, ISBI06, pp. 1376- 1379.
    • M. Hatt, N. Boussion, F. Lamare, C. Collet, F. Salzenstein, C. Roux, Y. Bizais, C. Cheze-Le Rest, D. Visvikis, Fuzzy versus Hard Hidden Markov Chains Segmentation for Volume Determination and Quantitation in Noisy PET Images, ISBI06, pp. 1376- 1379.
  • 10
    • 0031103069 scopus 로고    scopus 로고
    • Associate Member, IEEE, Estimation of Fuzzy Gaussian Mixture and Unsupervised Statistical Image Segmentation
    • H. Caillol, W. Pieczynski, A. Hillion, Associate Member, IEEE, Estimation of Fuzzy Gaussian Mixture and Unsupervised Statistical Image Segmentation, IEEE Trans. Im. Process., Vol. 6, No. 3, 1997.
    • (1997) IEEE Trans. Im. Process , vol.6 , Issue.3
    • Caillol, H.1    Pieczynski, W.2    Hillion, A.3
  • 12
    • 36348964384 scopus 로고    scopus 로고
    • K. Jordan, IEC emission phantom Appendix Performance evaluation of positron emission tomographs, Medical and Public Health Research Programme of the European Community
    • K. Jordan, IEC emission phantom Appendix Performance evaluation of positron emission tomographs, Medical and Public Health Research Programme of the European Community.
  • 13
  • 14
    • 0036624497 scopus 로고    scopus 로고
    • One-pass list-mode EM algorithm for high-resolution 3D PET image reconstruction into large array
    • A.J. Reader, S. Ally, F. Bakatselos, R. Manavaki, R.J. Walledge, A.P. Jeavons et al., One-pass list-mode EM algorithm for high-resolution 3D PET image reconstruction into large array, IEEE Trans. Nucl. Sci. 49(3), 693-699, 2002.
    • (2002) IEEE Trans. Nucl. Sci , vol.49 , Issue.3 , pp. 693-699
    • Reader, A.J.1    Ally, S.2    Bakatselos, F.3    Manavaki, R.4    Walledge, R.J.5    Jeavons, A.P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.