메뉴 건너뛰기




Volumn , Issue , 2007, Pages

Dynamic modelling, simulation and analysis of an offshore variable-speed directly-driven permanent-magnet wind energy conversion and storage system (WECSS)

Author keywords

Modelling; Permanent magnet generators; Pulse width modulated (PWM) power converters; Wind power generation

Indexed keywords

COMPUTER SIMULATION; ENERGY STORAGE; PERMANENT MAGNETS; POWER CONVERTERS; PULSE WIDTH MODULATION; SYNCHRONOUS GENERATORS; VARIABLE SPEED DRIVES; WIND POWER;

EID: 36348972230     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/oceanse.2007.4302438     Document Type: Conference Paper
Times cited : (40)

References (13)
  • 1
    • 0037291008 scopus 로고    scopus 로고
    • General model for representing variable speed wind turbines in power system dynamics simulations
    • Feb
    • J.G. Slootweg, S.W.H. De Haan, H. Polinder, and W.L. Kling, "General model for representing variable speed wind turbines in power system dynamics simulations," IEEE Trans. Power Systems, vol. 8, no. 1, pp. 144-151, Feb. 2003.
    • (2003) IEEE Trans. Power Systems , vol.8 , Issue.1 , pp. 144-151
    • Slootweg, J.G.1    De Haan, S.W.H.2    Polinder, H.3    Kling, W.L.4
  • 2
    • 35348879126 scopus 로고    scopus 로고
    • Interconnecting offshore wind farms using multiterminal VSC-based HVDC
    • Montreal, June, 7pp
    • D.Jovcic, "Interconnecting offshore wind farms using multiterminal VSC-based HVDC," in Proc. 2006 IEEE Power Engineering Society General Meeting, Montreal, June 2006, 7pp.
    • (2006) Proc. 2006 IEEE Power Engineering Society General Meeting
    • Jovcic, D.1
  • 3
    • 34250802384 scopus 로고    scopus 로고
    • Comparison of International Regulations for Connection of Wind Turbines to the Network
    • Sweden, Mar
    • J.Matevosyan, T. Ackermann, S. Bolik, and L. Söder, "Comparison of International Regulations for Connection of Wind Turbines to the Network," 2004 Nordic Wind Power, Sweden, Mar. 2004.
    • (2004) 2004 Nordic Wind Power
    • Matevosyan, J.1    Ackermann, T.2    Bolik, S.3    Söder, L.4
  • 4
    • 30944445974 scopus 로고    scopus 로고
    • International review of grid connection requirements for wind turbines
    • Sweden, Mar
    • J. Jauch, P. Sorensen, B Bak-Jensen, "International review of grid connection requirements for wind turbines," 2004 Nordic Wind Power, Sweden, Mar. 2004.
    • (2004) 2004 Nordic Wind Power
    • Jauch, J.1    Sorensen, P.2    Bak-Jensen, B.3
  • 5
    • 33244483622 scopus 로고    scopus 로고
    • Control of permanent-magnet generators applied to variable-speed wind-energy systems connected to the grid
    • Mar
    • M. Chinchilla, S. Arnaltes, and J. C. Burgos, "Control of permanent-magnet generators applied to variable-speed wind-energy systems connected to the grid," IEEE Trans. Energy Conversion, vol. 21, no. 1, pp. 130-135, Mar. 2006.
    • (2006) IEEE Trans. Energy Conversion , vol.21 , Issue.1 , pp. 130-135
    • Chinchilla, M.1    Arnaltes, S.2    Burgos, J.C.3
  • 8
    • 33645730360 scopus 로고    scopus 로고
    • Compensation of particle accelerator load using converter controlled pulse compensator
    • Apr
    • D. Jovic, and K. Kahle, "Compensation of particle accelerator load using converter controlled pulse compensator," IEEE Trans Power Del., vol. 21, no. 2, pp. 801-808, Apr. 2006.
    • (2006) IEEE Trans Power Del , vol.21 , Issue.2 , pp. 801-808
    • Jovic, D.1    Kahle, K.2
  • 9
    • 33744513173 scopus 로고    scopus 로고
    • A neutral-point clamped converter system for direct-drive variable-speed wind power unit
    • Jun
    • A. Yazdani, R. Iravani, "A neutral-point clamped converter system for direct-drive variable-speed wind power unit," IEEE Trans. Energy Conversion., vol. 21, no. 2, pp. 596-607, Jun. 2006.
    • (2006) IEEE Trans. Energy Conversion , vol.21 , Issue.2 , pp. 596-607
    • Yazdani, A.1    Iravani, R.2
  • 11
    • 13844299159 scopus 로고    scopus 로고
    • Sensorless output maximization control for variable-speed wind generation system using IPMSG
    • Jan/Feb
    • S. Morimoto, H. Nakayama, M. Sanada, Y. Takeda, "Sensorless output maximization control for variable-speed wind generation system using IPMSG," IEEE Trans. Ind. Applications, vol. 41, no. 1, pp. 60-67, Jan/Feb. 2005.
    • (2005) IEEE Trans. Ind. Applications , vol.41 , Issue.1 , pp. 60-67
    • Morimoto, S.1    Nakayama, H.2    Sanada, M.3    Takeda, Y.4
  • 12
    • 33645725164 scopus 로고    scopus 로고
    • Design of a maximum power tracking system for wind-energy-conversion applications
    • Apr
    • E. koutroulis, K. kalaitzakis, "Design of a maximum power tracking system for wind-energy-conversion applications," IEEE Trans. Ind Elec., vol. 53, no. 2, pp. 486-494, Apr. 2006.
    • (2006) IEEE Trans. Ind Elec , vol.53 , Issue.2 , pp. 486-494
    • koutroulis, E.1    kalaitzakis, K.2
  • 13
    • 0031269266 scopus 로고    scopus 로고
    • Basic control of unified power flow controller
    • Nov
    • I. Papic, P. Zunko, D. Povh, and M. Weinhold, "Basic control of unified power flow controller," IEEE Trans. Power Systems, vol. 12, no. 4, pp. 1734-1739, Nov. 1997.
    • (1997) IEEE Trans. Power Systems , vol.12 , Issue.4 , pp. 1734-1739
    • Papic, I.1    Zunko, P.2    Povh, D.3    Weinhold, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.