메뉴 건너뛰기




Volumn 22, Issue 4, 2006, Pages 335-345

Swan-Ganz catheter in hemodynamic monitoring

Author keywords

Catheter : Swan Ganz; Monitoring : Hemodynamic

Indexed keywords

OXYGEN;

EID: 36348970522     PISSN: 09709185     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (9)

References (42)
  • 1
    • 0033788304 scopus 로고    scopus 로고
    • Non invasive cardiac output monitoring by aortic blood flow measurement with Dynemo 3000
    • Boulnois JI, Pechoux T: Non invasive cardiac output monitoring by aortic blood flow measurement with Dynemo 3000. JCMC 2000; 16: 127-140.
    • (2000) JCMC , vol.16 , pp. 127-140
    • Boulnois, J.I.1    Pechoux, T.2
  • 2
    • 0036174728 scopus 로고    scopus 로고
    • Clinical review: Hemodynamic monitoring in the intensive care unit
    • Boldt J: Clinical review: Hemodynamic monitoring in the intensive care unit. Critical Care 2002; 6: 52-59.
    • (2002) Critical Care , vol.6 , pp. 52-59
    • Boldt, J.1
  • 3
    • 0020636555 scopus 로고
    • Pulmonary artery occlusion pressure: Clinical Physiology, measurement and interpretation
    • O'Quin R, Marini J. J: Pulmonary artery occlusion pressure: Clinical Physiology, measurement and interpretation. Am Rev Respir Dis 1983; 128: 319.
    • (1983) Am Rev Respir Dis , vol.128 , pp. 319
    • O'Quin, R.1    Marini, J.J.2
  • 4
    • 0021247767 scopus 로고
    • Cardiovascular pulmonary monitoring in the intensive care unit. Part 1
    • Weidmann H. P, Matthay M. A, Matthay R. A: Cardiovascular pulmonary monitoring in the intensive care unit. Part 1. Chest 1984; 85: 537.
    • (1984) Chest , vol.85 , pp. 537
    • Weidmann, H.P.1    Matthay, M.A.2    Matthay, R.A.3
  • 5
    • 0014964972 scopus 로고
    • Catheterization of the heart in man with the use of a flow directed balloon- tipped catheter
    • Swan H. J. C, Ganz W, Forrester J et al: Catheterization of the heart in man with the use of a flow directed balloon- tipped catheter. N Engl J Med 1970; 283: 447.
    • (1970) N Engl J Med , vol.283 , pp. 447
    • Swan, H.J.C.1    Ganz, W.2    Forrester, J.3
  • 6
    • 0027499422 scopus 로고
    • Practice guidelines for pulmonary artery catheterization: A report by the American Society of Anaesthesiologists Task Force on Pulmonary artery catheterization
    • Roizen M. F, Berger D. L, Gabel R. A et al: Practice guidelines for pulmonary artery catheterization: A report by the American Society of Anaesthesiologists Task Force on Pulmonary artery catheterization. Anesthesiology 1993; 78: 380.
    • (1993) Anesthesiology , vol.78 , pp. 380
    • Roizen, M.F.1    Berger, D.L.2    Gabel, R.A.3
  • 7
    • 36348959639 scopus 로고
    • Where pulmonary catheters go: Intrathoracic distribution
    • Benumof J. L et al. Where pulmonary catheters go: Intrathoracic distribution. Anesthesiology 1977; 47: 455-65.
    • (1977) Anesthesiology , vol.47 , pp. 455-465
    • Benumof, J.L.1
  • 8
    • 0022395743 scopus 로고
    • Wedge pressure in large versus small pulmonary arteries to detect pulmonary vasoconstriction
    • Zidulka A, Hakim T. S: Wedge pressure in large versus small pulmonary arteries to detect pulmonary vasoconstriction. J Appl Physiol 1985; 59: 1329.
    • (1985) J Appl Physiol , vol.59 , pp. 1329
    • Zidulka, A.1    Hakim, T.S.2
  • 9
    • 36348996573 scopus 로고    scopus 로고
    • Mark J. B: Pulmonary artery wedge pressure. In: Atlas of Cardiovascular monitoring. Mark J. B, Churchill Livingstone, 1998, p 39.
    • Mark J. B: Pulmonary artery wedge pressure. In: Atlas of Cardiovascular monitoring. Mark J. B, Churchill Livingstone, 1998, p 39.
  • 10
    • 0015789991 scopus 로고
    • Comparison of pulmonary wedge and left atrial preesure in man
    • Waltson A, Kendall M. E. Comparison of pulmonary wedge and left atrial preesure in man. Am Heart J 1973; 86: 159-64.
    • (1973) Am Heart J , vol.86 , pp. 159-164
    • Waltson, A.1    Kendall, M.E.2
  • 11
    • 78651150557 scopus 로고
    • Distribution of blood flow in isolated lung: Relation to vascular and alveolar pressures
    • West J. B, Dollery C. T, Naimark A. Distribution of blood flow in isolated lung: Relation to vascular and alveolar pressures. J Appl Physiol 1964; 19: 713.
    • (1964) J Appl Physiol , vol.19 , pp. 713
    • West, J.B.1    Dollery, C.T.2    Naimark, A.3
  • 13
    • 0021076099 scopus 로고
    • Cardiac output by the thermodilution technique; effect of injectate volume and temperature on accuracy and reproducibility in critically ill patients
    • Elkazan Y et al. Cardiac output by the thermodilution technique; effect of injectate volume and temperature on accuracy and reproducibility in critically ill patients. Chest 1983; 84: 418-22.
    • (1983) Chest , vol.84 , pp. 418-422
    • Elkazan, Y.1
  • 14
    • 0016812061 scopus 로고
    • Measurement of cardiac output by thermodilution
    • Weisel R. D, Berger R. L, Hechtman H. B: Measurement of cardiac output by thermodilution. N Engl J Med 1975; 292: 682.
    • (1975) N Engl J Med , vol.292 , pp. 682
    • Weisel, R.D.1    Berger, R.L.2    Hechtman, H.B.3
  • 16
    • 0020956220 scopus 로고
    • Right ventricular function in acute disease etates: Pathophysiologic consideration
    • Sibbald W. S, Drieger A. A. Right ventricular function in acute disease etates: Pathophysiologic consideration. Crit Care Med 1983; 11: 339-345.
    • (1983) Crit Care Med , vol.11 , pp. 339-345
    • Sibbald, W.S.1    Drieger, A.A.2
  • 18
    • 0019412741 scopus 로고
    • Thermodilution right ventricular volume: A novel and better predictor of volume replacement in acute thermal injury
    • Martyn J. A. J, Snider M. T, Farago L. F, Burke J. F: Thermodilution right ventricular volume: A novel and better predictor of volume replacement in acute thermal injury. J Trauma 1981; 21: 619-624.
    • (1981) J Trauma , vol.21 , pp. 619-624
    • Martyn, J.A.J.1    Snider, M.T.2    Farago, L.F.3    Burke, J.F.4
  • 19
    • 0020602774 scopus 로고
    • Unsuspected right ventricular dysfunction in shock and sepsis
    • Hoffman M. J, Greenfield L. L, Sugerman H. J: Unsuspected right ventricular dysfunction in shock and sepsis. Nucl Med 1983; 198: 307-312.
    • (1983) Nucl Med , vol.198 , pp. 307-312
    • Hoffman, M.J.1    Greenfield, L.L.2    Sugerman, H.J.3
  • 20
    • 0020569247 scopus 로고
    • Measurement of ejection fraction by thermodilution techniques
    • Kay H, Afshan M, Barash P G, Measurement of ejection fraction by thermodilution techniques, J surg Res 1983; 34: 337.
    • (1983) J surg Res , vol.34 , pp. 337
    • Kay, H.1    Afshan, M.2    Barash, P.G.3
  • 21
    • 0023225234 scopus 로고
    • Thermodilution measurement of the right ventricular ejection fraction
    • Morrison DA, Stovall R, Sensecqua J, Thermodilution measurement of the right ventricular ejection fraction, Cathet Cardiovasc Diagn 1987; 13: 167.
    • (1987) Cathet Cardiovasc Diagn , vol.13 , pp. 167
    • Morrison, D.A.1    Stovall, R.2    Sensecqua, J.3
  • 22
    • 0023150039 scopus 로고
    • Bedside evaluation of right ventricular performance using a rapid computerized thermodilution method
    • Dhainaut J-F, Brunet F, Monsallier J F, Bedside evaluation of right ventricular performance using a rapid computerized thermodilution method, Crit Care Med 1987; 15: 148.
    • (1987) Crit Care Med , vol.15 , pp. 148
    • Dhainaut, J.-F.1    Brunet, F.2    Monsallier, J.F.3
  • 23
    • 0030851401 scopus 로고    scopus 로고
    • The new pulmonary artery catheters: Continuous venous oximetry, 'right ventricular ejection fraction, and continous cardiac output
    • Nelson L D, The new pulmonary artery catheters: continuous venous oximetry, 'right ventricular ejection fraction, and continous cardiac output, New Horiz 5: 251, 1997.
    • (1997) New Horiz , vol.5 , pp. 251
    • Nelson, L.D.1
  • 24
    • 0027382320 scopus 로고
    • Accurate assessment of right ventricular function in acute respiratory failure
    • Her C, Lees D E, Accurate assessment of right ventricular function in acute respiratory failure, Crit Care Med 21: 1665, 1993.
    • (1993) Crit Care Med , vol.21 , pp. 1665
    • Her, C.1    Lees, D.E.2
  • 25
    • 0027382868 scopus 로고
    • Hemodynamic monitoring: A new day dawning
    • Nelson L D, Hemodynamic monitoring: A new day dawning, Crit Care Med 1993; 21: 1626.
    • (1993) Crit Care Med , vol.21 , pp. 1626
    • Nelson, L.D.1
  • 26
    • 0025663363 scopus 로고
    • Measuirement of right ventricular volume measurement during fluid challenge
    • Reuse C, Vincent J L, Pinsky M R, Measuirement of right ventricular volume measurement during fluid challenge, Chest 1990; 98: 1450.
    • (1990) Chest , vol.98 , pp. 1450
    • Reuse, C.1    Vincent, J.L.2    Pinsky, M.R.3
  • 27
    • 0031159572 scopus 로고    scopus 로고
    • Clinical application of ventricular end-systolic elastance and the ventricular pressure-volume diagram
    • Chang M C, Mondy J S, Meredith J W, Clinical application of ventricular end-systolic elastance and the ventricular pressure-volume diagram Shock 1997; 7: 413.
    • (1997) Shock , vol.7 , pp. 413
    • Chang, M.C.1    Mondy, J.S.2    Meredith, J.W.3
  • 28
    • 0022356941 scopus 로고
    • Continuous mixed venous oxygen saturation measurement: A significant advance in hemodynamic monitoring?
    • Norfleet E. A, Watson C. B: Continuous mixed venous oxygen saturation measurement: A significant advance in hemodynamic monitoring? J Clin Monit 1985; 1: 245.
    • (1985) J Clin Monit , vol.1 , pp. 245
    • Norfleet, E.A.1    Watson, C.B.2
  • 29
    • 0021273264 scopus 로고
    • A review of pulmonary artery catheterization in 6245 patients
    • Shah K. B, Rao T. L. K, Laughlin S et al. A review of pulmonary artery catheterization in 6245 patients. Anesthesiology 1984; 61: 271
    • (1984) Anesthesiology , vol.61 , pp. 271
    • Shah, K.B.1    Rao, T.L.K.2    Laughlin, S.3
  • 30
    • 0008584799 scopus 로고    scopus 로고
    • A review of pulmonary artey catheterization in 5306 consecutive patients undergoing cardiac surgery
    • Procaccini B, Clementi G, Miletti E et al. A review of pulmonary artey catheterization in 5306 consecutive patients undergoing cardiac surgery. Br J Anaesth 1998; 80: A26.
    • (1998) Br J Anaesth , vol.80
    • Procaccini, B.1    Clementi, G.2    Miletti, E.3
  • 31
    • 0019557638 scopus 로고
    • Complications of the flow directed pulmonary artery catheter: A peospective analysis in 219 patients
    • Sise C. J, Hollingsworth P, Brimm J. E et al. Complications of the flow directed pulmonary artery catheter: A peospective analysis in 219 patients. Crit Care Med 1981; 9: 315.
    • (1981) Crit Care Med , vol.9 , pp. 315
    • Sise, C.J.1    Hollingsworth, P.2    Brimm, J.E.3
  • 32
    • 0020072115 scopus 로고
    • Thrombosis as a complication of pulmonary artery catheterization via the internal jugular vein
    • Chastre J, Cormud F, Bouchama A et al. Thrombosis as a complication of pulmonary artery catheterization via the internal jugular vein. N Engl J Med 1982l; 306: 278.
    • (1982) N Engl J Med , vol.306 , pp. 278
    • Chastre, J.1    Cormud, F.2    Bouchama, A.3
  • 33
    • 0016401628 scopus 로고
    • Pulmonary complications of the flow directed balloon tipped catheter
    • Foote G. A, Schabel S. I, Hodges M: Pulmonary complications of the flow directed balloon tipped catheter. N Engl Med 1974; 290: 927.
    • (1974) N Engl Med , vol.290 , pp. 927
    • Foote, G.A.1    Schabel, S.I.2    Hodges, M.3
  • 34
    • 36348964240 scopus 로고
    • Assessment of the sterility of long term catheterization using the thermodilution Swan Ganz catheter
    • Applefield J. J, Caruthers T. E, Reno D. J: Assessment of the sterility of long term catheterization using the thermodilution Swan Ganz catheter. Chest 1974; 65: 682.
    • (1974) Chest , vol.65 , pp. 682
    • Applefield, J.J.1    Caruthers, T.E.2    Reno, D.J.3
  • 35
    • 0022003312 scopus 로고
    • The cult of Swan Ganz catheter. Overuse and abuse of pulmonary artery flow catheters
    • Robin ED: The cult of Swan Ganz catheter. Overuse and abuse of pulmonary artery flow catheters. Ann Intern Med, 1985; 103: 445-449.
    • (1985) Ann Intern Med , vol.103 , pp. 445-449
    • Robin, E.D.1
  • 36
    • 0018939258 scopus 로고
    • (PA) catheterize or not to (PA ) catheterize that is the question
    • Lowenstein E, Teplic T : (PA) catheterize or not to (PA ) catheterize that is the question. Anesthesiology, 1980; 53: 361-363.
    • (1980) Anesthesiology , vol.53 , pp. 361-363
    • Lowenstein, E.1    Teplic, T.2
  • 37
    • 9544228424 scopus 로고    scopus 로고
    • The effectiveness of right heart catheterization in initial care of critically ill patients
    • Connors AFJ, Speroff T, Dawson NV etal : The effectiveness of right heart catheterization in initial care of critically ill patients. JAMA 1996; 276: 889-897.
    • (1996) JAMA , vol.276 , pp. 889-897
    • Connors, A.F.J.1    Speroff, T.2    Dawson, N.V.3
  • 38
    • 0034078655 scopus 로고    scopus 로고
    • The incidence of major morbidity in critically ill patients managed with pulmonary artery catheters : A meta - analysis
    • Ivanov R,Allen J, Calvin J : The incidence of major morbidity in critically ill patients managed with pulmonary artery catheters : A meta - analysis. Crit Care Med, 2000; 28: 615-619.
    • (2000) Crit Care Med , vol.28 , pp. 615-619
    • Ivanov, R.1    Allen, J.2    Calvin, J.3
  • 39
    • 0027427633 scopus 로고
    • A randomized clinical trial of the effect of deliberate increase of oxygen delivery on mortality in high-risk surgical patients
    • Boyd O, Grounds R M, Bennett E D: A randomized clinical trial of the effect of deliberate increase of oxygen delivery on mortality in high-risk surgical patients. JAMA, 1993; 270: 2699-2707.
    • (1993) JAMA , vol.270 , pp. 2699-2707
    • Boyd, O.1    Grounds, R.M.2    Bennett, E.D.3
  • 40
    • 0030448751 scopus 로고    scopus 로고
    • Enhancement of perioperative tissue perfusion as a therapeutic strategy for major surgery
    • Boyd O, Bennett E D: Enhancement of perioperative tissue perfusion as a therapeutic strategy for major surgery. New Horiz, 1996; 4: 453-465.
    • (1996) New Horiz , vol.4 , pp. 453-465
    • Boyd, O.1    Bennett, E.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.