메뉴 건너뛰기




Volumn 40, Issue 2, 2008, Pages 71-82

A development of easy-to-use tool for fault detection and diagnosis in building air-conditioning systems

Author keywords

Building air conditioning system; Easy to use tool; Fault detection and diagnosis; Simulation

Indexed keywords

ELECTRIC POWER UTILIZATION; FAILURE ANALYSIS; FAULT DETECTION; MATHEMATICAL MODELS; TEMPERATURE MEASUREMENT;

EID: 36348967762     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2007.01.011     Document Type: Article
Times cited : (32)

References (10)
  • 1
    • 36349029480 scopus 로고    scopus 로고
    • Japan Building Mechanical and Electrical Engineers Association, Troubleshooting for Architectural Equipment, Ohmsha, 2004.
  • 2
    • 0034826027 scopus 로고    scopus 로고
    • Fault detection in HVAC systems using model-based feedforward control
    • Salsbury T.I., and Diamond R.C. Fault detection in HVAC systems using model-based feedforward control. Energy and Buildings 33 (2001) 403-415
    • (2001) Energy and Buildings , vol.33 , pp. 403-415
    • Salsbury, T.I.1    Diamond, R.C.2
  • 4
    • 0035216497 scopus 로고    scopus 로고
    • Development of ARX model based off-line FDD technique for energy efficient buildings
    • Yoshida H., and Kumar S. Development of ARX model based off-line FDD technique for energy efficient buildings. Renewable Energy 22 (2001) 53-59
    • (2001) Renewable Energy , vol.22 , pp. 53-59
    • Yoshida, H.1    Kumar, S.2
  • 5
    • 36349032572 scopus 로고    scopus 로고
    • K. Kuniyoshi, Y. Akashi, T. Hayashi, D. Sumiyoshi, Y.H. Song, T. Izaki, A study on energy-saving diagnosis of the air conditioning system in the building, part 1. Outline of the HVAC&R experimental analysis system, Kyushu Chapter Architectural Research Meeting (Environment) of Architectural Institute of Japan, 2005, pp. 437-440.
  • 7
    • 36349034305 scopus 로고    scopus 로고
    • Japan Building Mechanical and Electrical Engineers Association, Instruction Manual for HASP/ACSS/8502 Program, Standard Simulation Program for Air Conditioning Systems, 1986.
  • 9
    • 36349002631 scopus 로고    scopus 로고
    • Y.H. Song, Y. Akashi, K. Kuniyoshi, T. Hayashi, Study on fault detection and diagnosis of building air-conditioning system, part 2. Investigation of faulty status using calculation, Summaries of Technical Papers of Annual Meeting of Architectural Institute of Japan, D-2, 2005, pp. 1431-1432.
  • 10
    • 36349011137 scopus 로고    scopus 로고
    • K. Tanaka, D. Narumi, Y. Jinno, Y. Shimoda, M. Mizuno, Impact of a short-cut air flow around outdoor units of air conditioners on the energy consumption, Summaries of Technical Papers of Annual Meeting of Architectural Institute of Japan, D-2, 2005, pp. 65-68.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.