메뉴 건너뛰기




Volumn 6589, Issue , 2007, Pages

SMA micro actuators for active shape control, handling technologies and medical applications

Author keywords

Micro actuator; Micro gripper; Shape memory alloys (SMA)

Indexed keywords

BIOMEDICAL ENGINEERING; MICROFABRICATION; MICROSYSTEMS; SHAPE MEMORY EFFECT; SOLDERING; VALVES (MECHANICAL);

EID: 36249017854     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.724192     Document Type: Conference Paper
Times cited : (5)

References (17)
  • 8
    • 36248941895 scopus 로고    scopus 로고
    • th Int. Conf. on New Actuators, H. Borgmann, 579-582, Messe Bremen GmbH, Bremen, Germany, 2000.
    • th Int. Conf. on New Actuators, H. Borgmann, 579-582, Messe Bremen GmbH, Bremen, Germany, 2000.
  • 9
    • 0034985697 scopus 로고    scopus 로고
    • S. Bütefisch, S. Büttgenbach, New Differential-Type SMA Actuator for a Miniature Silicon Gripper, Proc. of SPIE Smart Structures and Devices, D. K. Sood, R. A. Lawes, V. V. Varadan, 4235, 102-107, SPIE, Melbourne, Australia, 2000.
    • S. Bütefisch, S. Büttgenbach, "New Differential-Type SMA Actuator for a Miniature Silicon Gripper", Proc. of SPIE Smart Structures and Devices, D. K. Sood, R. A. Lawes, V. V. Varadan, 4235, 102-107, SPIE, Melbourne, Australia, 2000.
  • 11
    • 2342629966 scopus 로고    scopus 로고
    • TiNi-Based Thin Films in MEMS Applications: A Review
    • Y. Fu, H. Du, W. Huang, S. Zhang, M. Hu, "TiNi-Based Thin Films in MEMS Applications: A Review", Sensors and Actuators A, 112, 395-408, 2004.
    • (2004) Sensors and Actuators A , vol.112 , pp. 395-408
    • Fu, Y.1    Du, H.2    Huang, W.3    Zhang, S.4    Hu, M.5
  • 12
    • 0001359336 scopus 로고    scopus 로고
    • Tactile microgripper for automated handling of microparts
    • G. Greitmann, R. A. Buser, "Tactile microgripper for automated handling of microparts", Sensors and Actuators A, 53, 410-415, 1996.
    • (1996) Sensors and Actuators A , vol.53 , pp. 410-415
    • Greitmann, G.1    Buser, R.A.2
  • 14
    • 41149173365 scopus 로고    scopus 로고
    • th international conference of the european society for precision engineering and nanotechnology (euspen 05), F. Chevrier, T. Taliercio, P. Falgayrettes, P. Gall-Borrut, 01, 325-328, Montpellier, France, 2005.
    • th international conference of the european society for precision engineering and nanotechnology (euspen 05), F. Chevrier, T. Taliercio, P. Falgayrettes, P. Gall-Borrut, Vol. 01, 325-328, Montpellier, France, 2005.
  • 15
    • 36248970017 scopus 로고    scopus 로고
    • SMA Driven Micro Grippers Combining Piezo-Resistive Gripping Force Sensors With Epon SU-8 Mechanics
    • Elsevier, Göteborg, Sweden
    • B. Hoxhold, M. R. Kirchhoff, S. Bütefisch, S. Büttgenbach, "SMA Driven Micro Grippers Combining Piezo-Resistive Gripping Force Sensors With Epon SU-8 Mechanics", Proc. of Eurosensors 2006, Vol. 2, 190-191, Elsevier, Göteborg, Sweden, 2006.
    • (2006) Proc. of Eurosensors 2006 , vol.2 , pp. 190-191
    • Hoxhold, B.1    Kirchhoff, M.R.2    Bütefisch, S.3    Büttgenbach, S.4
  • 16
    • 20444450895 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement: Far from ideal
    • T. Attmann, J. Cremer, G. Lutter, "Percutaneous aortic valve replacement: far from ideal", Thorac Cardiovasc Surg., 53, 131-132, 2005.
    • (2005) Thorac Cardiovasc Surg , vol.53 , pp. 131-132
    • Attmann, T.1    Cremer, J.2    Lutter, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.