메뉴 건너뛰기




Volumn 12, Issue 5, 2007, Pages 527-533

Improving the positioning accuracy of a neurosurgical robot system

Author keywords

Neurosurgical robot; Positioning accuracy; Robot calibration

Indexed keywords

BACKPROPAGATION; CALIBRATION; COMPUTER SIMULATION; KINEMATICS; NEURAL NETWORKS; NEUROSURGERY; POSITION CONTROL;

EID: 36249013151     PISSN: 10834435     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMECH.2007.905694     Document Type: Conference Paper
Times cited : (35)

References (17)
  • 1
    • 0023962312 scopus 로고
    • A robot with improved absolute positioning accuracy for CT guided stereolactic brain surgery
    • Feb
    • Y S. Kwoh, I. Hou, E. A. Lonckheere, and S. Hayati, "A robot with improved absolute positioning accuracy for CT guided stereolactic brain surgery," IEEE Trans. Biomed. Eng., vol. 35, no. 2, pp. 153-160, Feb. 1988.
    • (1988) IEEE Trans. Biomed. Eng , vol.35 , Issue.2 , pp. 153-160
    • Kwoh, Y.S.1    Hou, I.2    Lonckheere, E.A.3    Hayati, S.4
  • 4
    • 0003575886 scopus 로고
    • R. J. Maciunas, Ed, Park Ridge, IL: American Association of Neurological Surgeons
    • R. J. Maciunas, Ed., Interactive Image Guided Neurosurgery. Park Ridge, IL: American Association of Neurological Surgeons, 1993, pp. 17-44.
    • (1993) Interactive Image Guided Neurosurgery , pp. 17-44
  • 5
    • 0028001440 scopus 로고
    • The application accuracy of stereotactic frames
    • R. J. Maciunas, J. R. Galloway, and J. W. Latimar, "The application accuracy of stereotactic frames," Neurosurgery, vol. 35, no. 4, pp. 682-695, 1994.
    • (1994) Neurosurgery , vol.35 , Issue.4 , pp. 682-695
    • Maciunas, R.J.1    Galloway, J.R.2    Latimar, J.W.3
  • 6
    • 0034846492 scopus 로고    scopus 로고
    • Detection and correction of geometric distortion in 3-D MR images
    • M. Breeuwer, M. Holden, and W. Zylka, "Detection and correction of geometric distortion in 3-D MR images," Proc. SPIE, vol. 4322, no. 2, pp. 1110-1120, 2001.
    • (2001) Proc. SPIE , vol.4322 , Issue.2 , pp. 1110-1120
    • Breeuwer, M.1    Holden, M.2    Zylka, W.3
  • 7
    • 0000669245 scopus 로고
    • Studies in the robustness of multidimensional scaling: Perturbational analysis of classical scaling
    • R. Sibson, "Studies in the robustness of multidimensional scaling: Perturbational analysis of classical scaling," J. Royal Statist. Soc. B, vol. 41, pp. 217-229, 1979.
    • (1979) J. Royal Statist. Soc. B , vol.41 , pp. 217-229
    • Sibson, R.1
  • 9
    • 0032173355 scopus 로고    scopus 로고
    • J. M. Fitzpatrick, J. B. West, and C. R. Maurer, Jr., Predicting error in rigid-body point-based registration, IEEE Trans. Med. Imag., 17, no. 5, pp. 694-702, Oct. 1998.
    • J. M. Fitzpatrick, J. B. West, and C. R. Maurer, Jr., "Predicting error in rigid-body point-based registration," IEEE Trans. Med. Imag., vol. 17, no. 5, pp. 694-702, Oct. 1998.
  • 11
    • 0033402358 scopus 로고    scopus 로고
    • Effect of optical digitizer selection on the application accuracy of a surgical localization system - A quantitative comparison between the OPTOTRAK and FlashPoint tracking systems
    • Q. Li, L. Zamorano, Z. W. Jiang, J. X. Gong, A. Pandya, R. Perez, and G. F. Diaz, "Effect of optical digitizer selection on the application accuracy of a surgical localization system - A quantitative comparison between the OPTOTRAK and FlashPoint tracking systems," Comput. Aided Surg., vol. 4, no. 6, pp. 314-321, 1999.
    • (1999) Comput. Aided Surg , vol.4 , Issue.6 , pp. 314-321
    • Li, Q.1    Zamorano, L.2    Jiang, Z.W.3    Gong, J.X.4    Pandya, A.5    Perez, R.6    Diaz, G.F.7
  • 12
    • 0036068318 scopus 로고    scopus 로고
    • The application accuracy of the NeuroMate Robot - A quantitative comparison with frameless and frame-based surgical localization system
    • Q. Li L. Zamorano et al., "The application accuracy of the NeuroMate Robot - A quantitative comparison with frameless and frame-based surgical localization system," Comput. Aided Surg., vol. 7, pp. 90-98, 2002.
    • (2002) Comput. Aided Surg , vol.7 , pp. 90-98
    • Zamorano, Q.L.L.1
  • 13
    • 33748971641 scopus 로고    scopus 로고
    • Robotics in neurosurgery: State of the art and future technological challenges
    • L. Zamorano and Q. Li, "Robotics in neurosurgery: State of the art and future technological challenges," J. Med. Robot. Comput. Assisted. Surg., vol. 1, no. 1, pp. 1-16, 2004.
    • (2004) J. Med. Robot. Comput. Assisted. Surg , vol.1 , Issue.1 , pp. 1-16
    • Zamorano, L.1    Li, Q.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.