메뉴 건너뛰기




Volumn 6631, Issue , 2007, Pages

Laser Doppler perfusion imaging with a high-speed CMOS-camera

Author keywords

Blood flow; CMOS; Laser Doppler; Medical imaging; Perfusion monitoring

Indexed keywords

BLOOD; CAMERAS; DOPPLER EFFECT; IMAGE ANALYSIS; PHOTODETECTORS;

EID: 36249003477     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (25)
  • 1
    • 0019583049 scopus 로고
    • Model for laser doppler measurements of blood flow in tissue
    • R. Bonner and R. Nossal, "Model for laser doppler measurements of blood flow in tissue," Applied Optics 20(12), pp. 2097-2107, 1981.
    • (1981) Applied Optics , vol.20 , Issue.12 , pp. 2097-2107
    • Bonner, R.1    Nossal, R.2
  • 2
    • 0026207688 scopus 로고
    • Bio-speckle phenomena and their application to the evaluation of blood flow
    • Y. Aizu and T. Asakura, "Bio-speckle phenomena and their application to the evaluation of blood flow," Optics & Laser Technology 23(4), pp. 205-219, 1991.
    • (1991) Optics & Laser Technology , vol.23 , Issue.4 , pp. 205-219
    • Aizu, Y.1    Asakura, T.2
  • 3
    • 0026156875 scopus 로고
    • A laser doppler scanner for imaging blood flow in skin
    • T. Essex and P. Byrne, "A laser doppler scanner for imaging blood flow in skin," Journal of Biomedical Engineering 13, pp. 189-194, 1991.
    • (1991) Journal of Biomedical Engineering , vol.13 , pp. 189-194
    • Essex, T.1    Byrne, P.2
  • 5
    • 0036507635 scopus 로고    scopus 로고
    • Laser doppler perfusion imaging with a complimentary metal oxide semiconductor image sensor
    • A. Serov, W. Steenbergen, and F. de Mul, "Laser doppler perfusion imaging with a complimentary metal oxide semiconductor image sensor," Opt.Lett. 27(5), pp. 300-302, 2002.
    • (2002) Opt.Lett , vol.27 , Issue.5 , pp. 300-302
    • Serov, A.1    Steenbergen, W.2    de Mul, F.3
  • 6
    • 0000099185 scopus 로고    scopus 로고
    • Laser doppler and time-varying speckle: A reconciliations
    • J. Briers, "Laser doppler and time-varying speckle: A reconciliations," Journal of The Optical Society of America, A 13(2), pp. 45-350, 1996.
    • (1996) Journal of The Optical Society of America, A , vol.13 , Issue.2 , pp. 45-350
    • Briers, J.1
  • 7
    • 0035181228 scopus 로고    scopus 로고
    • Laser doppler, speckle and related techniques for blood perfusion mappingand imaging
    • J. D. Briers, "Laser doppler, speckle and related techniques for blood perfusion mappingand imaging," Physiological Measurements 22, pp. R35-R66, 2001.
    • (2001) Physiological Measurements , vol.22
    • Briers, J.D.1
  • 8
    • 23944507285 scopus 로고    scopus 로고
    • A comparison of two laser-based methods for determination of burn scar perfusion: Laser doppler versus laser speckle imaging
    • C. Stewart, R. Frank, K. Forrester, J. Tulip, R. Lindsay, and R. Bray, "A comparison of two laser-based methods for determination of burn scar perfusion: Laser doppler versus laser speckle imaging," Burns 31, pp. 744-752, 2005.
    • (2005) Burns , vol.31 , pp. 744-752
    • Stewart, C.1    Frank, R.2    Forrester, K.3    Tulip, J.4    Lindsay, R.5    Bray, R.6
  • 9
    • 21244498202 scopus 로고    scopus 로고
    • Full-field laser doppler perfusion imaging and monitoring with an intelligentcmos camera
    • A. Serov, B. Steinacher, and T. Lasser, "Full-field laser doppler perfusion imaging and monitoring with an intelligentcmos camera," Optics Express 13(10), pp. 3681-3689, 2005.
    • (2005) Optics Express , vol.13 , Issue.10 , pp. 3681-3689
    • Serov, A.1    Steinacher, B.2    Lasser, T.3
  • 10
    • 24144454179 scopus 로고    scopus 로고
    • High-speed laser doppler perfusion imaging using an integrating cmos imagesensor
    • A. Serov and T. Lasser, "High-speed laser doppler perfusion imaging using an integrating cmos imagesensor," Optic Express 13(17), pp. 6416-6428, 2005.
    • (2005) Optic Express , vol.13 , Issue.17 , pp. 6416-6428
    • Serov, A.1    Lasser, T.2
  • 11
    • 0036662524 scopus 로고    scopus 로고
    • New laser speckle flowgraphy system using ccd camera
    • N. Konishi, Y. Tokimoto, K. Kohra, and H. Fujii, "New laser speckle flowgraphy system using ccd camera," Optical Review 9(4), pp. 163-196, 2002.
    • (2002) Optical Review , vol.9 , Issue.4 , pp. 163-196
    • Konishi, N.1    Tokimoto, Y.2    Kohra, K.3    Fujii, H.4
  • 12
    • 0141644107 scopus 로고    scopus 로고
    • Modified laser speckle imaging method with improved spatial resolution
    • Jul
    • H. Cheng, Q. Luo, S. Zeng, S. Chen, J. Cen, and H. Gong, "Modified laser speckle imaging method with improved spatial resolution.," Journal of Biomedical Optics 8, pp. 559-564, Jul 2003.
    • (2003) Journal of Biomedical Optics , vol.8 , pp. 559-564
    • Cheng, H.1    Luo, Q.2    Zeng, S.3    Chen, S.4    Cen, J.5    Gong, H.6
  • 13
    • 33745302821 scopus 로고    scopus 로고
    • Combined laser doppler and laser speckle imaging for real-time blood flow measurements
    • Mar
    • A. Serov and T. Lasser, "Combined laser doppler and laser speckle imaging for real-time blood flow measurements," Proc. SPIE 6094, pp. 33-40, Mar. 2006.
    • (2006) Proc. SPIE , vol.6094 , pp. 33-40
    • Serov, A.1    Lasser, T.2
  • 14
    • 0019579052 scopus 로고
    • Flow visualization by means of single-exposure speckle photography
    • A. F. Fercher and J. D. Briers, "Flow visualization by means of single-exposure speckle photography," Optics Communications 37(5), pp. 326-330, 1981.
    • (1981) Optics Communications , vol.37 , Issue.5 , pp. 326-330
    • Fercher, A.F.1    Briers, J.D.2
  • 15
    • 0000823973 scopus 로고    scopus 로고
    • Laser speckle contrast analysis (lasca): A nonscanning, full-field technique for monitoring capillary blood flow
    • Apr
    • J. Briers and S. Webster, "Laser speckle contrast analysis (lasca): a nonscanning, full-field technique for monitoring capillary blood flow," Journal of Biomedical Optics 1, pp. 174-179, Apr. 1996.
    • (1996) Journal of Biomedical Optics , vol.1 , pp. 174-179
    • Briers, J.1    Webster, S.2
  • 16
    • 0000602849 scopus 로고    scopus 로고
    • Capillary-blood-flow monitoring using laser speckle contrast analysis (lasca): Improving the dynamic range
    • May
    • G. Richards and J. Briers, "Capillary-blood-flow monitoring using laser speckle contrast analysis (lasca): improving the dynamic range," Proc. SPIE 2981, pp. 160-171, May 1997.
    • (1997) Proc. SPIE , vol.2981 , pp. 160-171
    • Richards, G.1    Briers, J.2
  • 17
    • 0032403966 scopus 로고    scopus 로고
    • Laser speckle contrast analysis (lasca): A real-time solution for monitoring capillary blood flow and velocity
    • July
    • X.-W. He and J. D. Briers, "Laser speckle contrast analysis (lasca): a real-time solution for monitoring capillary blood flow and velocity," Proc. SPIE 3337, pp. 98-107, July 1998.
    • (1998) Proc. SPIE , vol.3337 , pp. 98-107
    • He, X.-W.1    Briers, J.D.2
  • 18
    • 0032225589 scopus 로고    scopus 로고
    • Laser speckle contrast analysis (lasca) for blood flow visualization: Improved image processing
    • June
    • J. D. Briers and X.-W. He, "Laser speckle contrast analysis (lasca) for blood flow visualization: improved image processing," Proc. SPIE 3252, pp. 26-33, June 1998.
    • (1998) Proc. SPIE , vol.3252 , pp. 26-33
    • Briers, J.D.1    He, X.-W.2
  • 19
    • 0032735763 scopus 로고    scopus 로고
    • Capillary blood flow monitoring using laser speckle contrast analysis (lasca)
    • January
    • J. D. Briers, G. Richards, and X. Wei He, "Capillary blood flow monitoring using laser speckle contrast analysis (lasca)," Journal of Biomedical Optics A, pp. 164-175, January 1999.
    • (1999) Journal of Biomedical Optics A , pp. 164-175
    • Briers, J.D.1    Richards, G.2    Wei He, X.3
  • 20
    • 0032648168 scopus 로고    scopus 로고
    • Time-dependent speckle contrast measurements for blood microcirculation monitoring
    • May
    • D. Zimnyakov, A. Mishin, A. Bednov, C. Cheung, V. Tuchin, and A. Yodh, "Time-dependent speckle contrast measurements for blood microcirculation monitoring," Proc. SPIE 3599, pp. 157-166, May 1999.
    • (1999) Proc. SPIE , vol.3599 , pp. 157-166
    • Zimnyakov, D.1    Mishin, A.2    Bednov, A.3    Cheung, C.4    Tuchin, V.5    Yodh, A.6
  • 21
    • 0037405441 scopus 로고    scopus 로고
    • R. Bray, K. Forrester, C. Leonard, R. Mcarthur, and R. Tulip, J.and Lindsay, Laser doppler imaging of burn scars: A comparison of wavelength andscanningmethods, Burns 29(3), pp. 199-206, 2003.
    • R. Bray, K. Forrester, C. Leonard, R. Mcarthur, and R. Tulip, J.and Lindsay, "Laser doppler imaging of burn scars: A comparison of wavelength andscanningmethods," Burns 29(3), pp. 199-206, 2003.
  • 23
    • 23844468849 scopus 로고    scopus 로고
    • S. Nadkarni, B. Bouma, T. Helg, R. Chan, A. Halpern, E.and Chau, M. Minsky, J. Motz, S. Houser, and G. Tearney, Characterization of atheroslerotic plaques by laser speckle imaging, Circulation 112, pp. 885-892, 2005.
    • S. Nadkarni, B. Bouma, T. Helg, R. Chan, A. Halpern, E.and Chau, M. Minsky, J. Motz, S. Houser, and G. Tearney, "Characterization of atheroslerotic plaques by laser speckle imaging," Circulation 112, pp. 885-892, 2005.
  • 25
    • 0026794438 scopus 로고
    • The relevance of posturally induced microvascular constriction after revascularisation in patients with chronic leg ischaemia
    • Sep
    • D. T. Ubbink, P. J. Kitslaar, J. H. Tordoir, G. J. Tangelder, R. S. Reneman, and M. J. Jacobs, "The relevance of posturally induced microvascular constriction after revascularisation in patients with chronic leg ischaemia.," European Journal of Vascular Surgery 6, pp. 525-532, Sep 1992.
    • (1992) European Journal of Vascular Surgery , vol.6 , pp. 525-532
    • Ubbink, D.T.1    Kitslaar, P.J.2    Tordoir, J.H.3    Tangelder, G.J.4    Reneman, R.S.5    Jacobs, M.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.