Volumn 116, Issue , 2005, Pages 447-452

Computed quality assessment of MPEG4-compressed DICOM video data

Author keywords

Computer Assisted image processing; Coronary angiography; Quality control; Telemedicine

Indexed keywords

ANGIOGRAPHY; COMPUTERIZED TOMOGRAPHY; DIGITAL DEVICES; DIGITAL STORAGE; ECHOCARDIOGRAPHY; IMAGE COMPRESSION; MEDICAL IMAGING; QUALITY CONTROL; TELEMEDICINE; ULTRASONIC IMAGING;

EID: 36248989300     PISSN: 09269630     EISSN: 18798365     Source Type: Book Series    
DOI: None     Document Type: Conference Paper
Times cited : (14)

References (25)
  • 1
    • 0031136809 scopus 로고    scopus 로고
    • Understanding and using DICOM, the data interchange standard for biomedical imaging
    • Bidgood WD, Jr., Horii SC, Prior FW, Van Syckle DE. Understanding and using DICOM, the data interchange standard for biomedical imaging. J Am Med Inform Assoc 1997; 4(3): 199-212.
    • (1997) J Am Med Inform Assoc , vol.4 , Issue.3 , pp. 199-212
    • Bidgood Jr., W.D.1    Horii, S.C.2    Prior, F.W.3    Van Syckle, D.E.4
  • 2
    • 0030754140 scopus 로고    scopus 로고
    • Digital imaging standards and system interoperability
    • Balis UJ. Digital imaging standards and system interoperability. Clin Lab Med 1997; 17(2): 315-322.
    • (1997) Clin Lab Med , vol.17 , Issue.2 , pp. 315-322
    • Balis, U.J.1
  • 3
    • 0032588476 scopus 로고    scopus 로고
    • Anatomy of picture archiving and communications systems: Nuts and bolts- -image acquisition: Getting digital images from imaging modalities
    • Andriole KP. Anatomy of picture archiving and Communications systems: nuts and bolts- -image acquisition: getting digital images from imaging modalities. J Digit Imaging 1999; 12(2 Suppl 1): 216-217.
    • (1999) J Digit Imaging , vol.12 , Issue.2 SUPPL. 1 , pp. 216-217
    • Andriole, K.P.1
  • 4
    • 0035354125 scopus 로고    scopus 로고
    • Breast magnetic resonance imaging: A computer-based analysis of enhancement curves
    • Setti E, Trecate G, Ferrari M, Mainardi L, Musumeci R. Breast magnetic resonance imaging: A computer-based analysis of enhancement curves. J Digit Imaging 2001; 14(2 Suppl 1): 226-228.
    • (2001) J Digit Imaging , vol.14 , Issue.2 SUPPL. 1 , pp. 226-228
    • Setti, E.1    Trecate, G.2    Ferrari, M.3    Mainardi, L.4    Musumeci, R.5
  • 5
    • 0034760796 scopus 로고    scopus 로고
    • DICOM - A new approach in medical under- And postgraduate education
    • Burger R, Kunzel KH, Brenner E. DICOM - A new approach in medical under- And postgraduate education. Med Educ 2001; 35(11): 1076-1077.
    • (2001) Med Educ , vol.35 , Issue.11 , pp. 1076-1077
    • Burger, R.1    Kunzel, K.H.2    Brenner, E.3
  • 6
    • 0036364860 scopus 로고    scopus 로고
    • A review of guidelines and standards for telemedicine
    • Loane M, Wootton R. A review of guidelines and standards for telemedicine. J Telemed Telecare 2002; 8(2): 63-71.
    • (2002) J Telemed Telecare , vol.8 , Issue.2 , pp. 63-71
    • Loane, M.1    Wootton, R.2
  • 7
    • 0036359189 scopus 로고    scopus 로고
    • Experience with a DICOM-compatible digital pediatric echocardiography laboratory
    • Frommelt PC, Whitstone EN, Frommelt MA. Experience with a DICOM-compatible digital pediatric echocardiography laboratory. Pediatr Cardiol 2002; 23(1): 53-57.
    • (2002) Pediatr Cardiol , vol.23 , Issue.1 , pp. 53-57
    • Frommelt, P.C.1    Whitstone, E.N.2    Frommelt, M.A.3
  • 9
    • 0036362813 scopus 로고    scopus 로고
    • NLM tele-educational application for radiologists to interpret mammography
    • Wu M, Zheng Y, North M, Pisano E. NLM tele-educational application for radiologists to interpret mammography. Proc AMIA Symp 2002; 909-913.
    • (2002) Proc AMIA Symp , pp. 909-913
    • Wu, M.1    Zheng, Y.2    North, M.3    Pisano, E.4
  • 10
    • 0031266507 scopus 로고    scopus 로고
    • Improving the interactivity and functionality of web-based radiology teaching files with the Java programming language
    • Eng J. Improving the interactivity and functionality of Web-based radiology teaching files with the Java programming language. Radiographics 1997; 17(6): 1567-1574.
    • (1997) Radiographics , vol.17 , Issue.6 , pp. 1567-1574
    • Eng, J.1
  • 12
    • 84886907816 scopus 로고    scopus 로고
    • Röntgenverordnung. 2005. http://www.laekb.de/40/10aesqr/05Gesetz/ Roentgenverordnung.pdf.
    • (2005) Röntgenverordnung
  • 13
    • 12944254587 scopus 로고    scopus 로고
    • Effects of MPEG compression on the quality and diagnostic accuracy of digital echocardiography studies
    • Spencer K, Solomon L, Mor-Avi V, Dean K, Weinert L, Gulati M et al. Effects of MPEG compression on the quality and diagnostic accuracy of digital echocardiography studies. J Am Soc Echocardiogr 2000; 13(1): 51-57.
    • (2000) J Am Soc Echocardiogr , vol.13 , Issue.1 , pp. 51-57
    • Spencer, K.1    Solomon, L.2    Mor-Avi, V.3    Dean, K.4    Weinert, L.5    Gulati, M.6
  • 14
    • 0037838683 scopus 로고    scopus 로고
    • Evaluation of the effect of varying MPEG-2 compression ratios on digital coronary angiographic assessment of stenosis severity
    • Okura Y, Matsumura Y, Hidaka K, Yokoyama H, Inada H, Harauchi H et al. Evaluation of the effect of varying MPEG-2 compression ratios on digital coronary angiographic assessment of stenosis severity. J Digit Imaging 2002; 15(4): 210-215.
    • (2002) J Digit Imaging , vol.15 , Issue.4 , pp. 210-215
    • Okura, Y.1    Matsumura, Y.2    Hidaka, K.3    Yokoyama, H.4    Inada, H.5    Harauchi, H.6
  • 15
    • 18544393430 scopus 로고    scopus 로고
    • Lossy (15:1) JPEG compression of digital coronary angiograms does not limit detection of subtle morphological features
    • Baker WA, Hearne SE, Spero LA, Morris KG, Harrington RA, Sketch MH, Jr. et al. Lossy (15:1) JPEG compression of digital coronary angiograms does not limit detection of subtle morphological features. Circulation 1997; 96(4): 1157-1164.
    • (1997) Circulation , vol.96 , Issue.4 , pp. 1157-1164
    • Baker, W.A.1    Hearne, S.E.2    Spero, L.A.3    Morris, K.G.4    Harrington, R.A.5    Sketch Jr., M.H.6
  • 16
    • 0034923310 scopus 로고    scopus 로고
    • Comparison of image compression viability for lossy and lossless JPEG and wavelet data reduction in coronary angiography
    • Brennecke R, Burgel U, Rippin G, Post F, Rupprecht HJ, Meyer J. Comparison of image compression viability for lossy and lossless JPEG and Wavelet data reduction in coronary angiography. Int J Cardiovasc Imaging 2001; 17(1): 1-12.
    • (2001) Int J Cardiovasc Imaging , vol.17 , Issue.1 , pp. 1-12
    • Brennecke, R.1    Burgel, U.2    Rippin, G.3    Post, F.4    Rupprecht, H.J.5    Meyer, J.6
  • 17
    • 0032588401 scopus 로고    scopus 로고
    • A comparison of wavelet and joint photographic experts group lossy compression methods applied to medical images
    • Iyriboz TA, Zukoski MJ, Hopper KD, Stagg PL. A comparison of wavelet and Joint Photographic Experts Group lossy compression methods applied to medical images. J Digit Imaging 1999; 12(2 Suppl 1): 14-17.
    • (1999) J Digit Imaging , vol.12 , Issue.2 SUPPL. 1 , pp. 14-17
    • Iyriboz, T.A.1    Zukoski, M.J.2    Hopper, K.D.3    Stagg, P.L.4
  • 18
    • 0034072318 scopus 로고    scopus 로고
    • The effect of lossy data compression on recognition of diagnostic features in digital coronary angiography
    • American College of Cardiology/European Society of Cardiology International Study of Angiographic Data Compression Phase I
    • Kerensky RA, Cusma JT, Kubilis P, Simon R, Bashore TM, Hirshfeld JW, Jr. et al. American College of Cardiology/European Society of Cardiology International Study of Angiographic Data Compression Phase I: The effect of lossy data compression on recognition of diagnostic features in digital coronary angiography. J Am Coll Cardiol 2000; 35(5): 1370-1379.
    • (2000) J Am Coll Cardiol , vol.35 , Issue.5 , pp. 1370-1379
    • Kerensky, R.A.1    Cusma, J.T.2    Kubilis, P.3    Simon, R.4    Bashore, T.M.5    Hirshfeld Jr., J.W.6
  • 20
    • 84886912949 scopus 로고    scopus 로고
    • Working Group on Multimedia Communications Coding and Performance: Objective Video Quality Measurement Using a Peak-Signal-to-Noise-Ratio (PSNR)
    • Working Group on Multimedia Communications Coding and Performance: Objective Video Quality Measurement Using a Peak-Signal-to-Noise-Ratio (PSNR). Committee T1 - Telecommunications. T1A1.1/2001-026R7. 2001.
    • (2001) Committee T1 - Telecommunications. T1A1.1/2001-026R7
  • 21
    • 0035061121 scopus 로고    scopus 로고
    • DVQ: A digital video quality metric based on human vision
    • Watson A, Hu J, McGowan J. DVQ: A digital video Quality metric based on human vision. Journal of Electronic Imaging 2001; 10(1): 20-29.
    • (2001) Journal of Electronic Imaging , vol.10 , Issue.1 , pp. 20-29
    • Watson, A.1    Hu, J.2    McGowan, J.3
  • 22
    • 84886881206 scopus 로고    scopus 로고
    • Offis. www.offis.org, 2005.
    • (2005) Offis
  • 24
    • 3242815330 scopus 로고    scopus 로고
    • Web-based delivery of medical multimedia contents using an MPEG-4 system
    • Yamakawa T, Toyabe S, Cao P, Akazawa K. Web-based delivery of medical multimedia contents using an MPEG-4 system. Comput Methods Programs Biomed 2004; 75(3): 259-264.
    • (2004) Comput Methods Programs Biomed , vol.75 , Issue.3 , pp. 259-264
    • Yamakawa, T.1    Toyabe, S.2    Cao, P.3    Akazawa, K.4
  • 25
    • 21644486184 scopus 로고    scopus 로고
    • Clinical validation of different echocardiographic motion pictures expert group-4 algorythms and compression levels for telemedicine
    • Barbier P, Alimento M, Berna G, Cavoretto D, Celeste F, Muratori M et al. Clinical validation of different echocardiographic motion pictures expert group-4 algorythms and compression levels for telemedicine. Medinfo 2004; 2004: 1339-1342.
    • (2004) Medinfo , vol.2004 , pp. 1339-1342
    • Barbier, P.1    Alimento, M.2    Berna, G.3    Cavoretto, D.4    Celeste, F.5    Muratori, M.6