메뉴 건너뛰기




Volumn 31, Issue 11, 2007, Pages 842-845

Personal digital assistant-based, internet-enabled remote communication system for a wearable pneumatic biventricular assist device

Author keywords

Cellular phone; Mobile communication; Pneumatic ventricular assist device; Telemanagement

Indexed keywords

DIGITAL DEVICES; FIBER OPTIC SENSORS; MOBILE TELECOMMUNICATION SYSTEMS; PERSONAL DIGITAL ASSISTANTS; PNEUMATICS;

EID: 36248970664     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2007.00475.x     Document Type: Article
Times cited : (2)

References (13)
  • 1
    • 0031239271 scopus 로고    scopus 로고
    • Portable pneumatic biventricular driver for the Thoratec ventricular assist device
    • Farrar DJ, Buck KE, Coulter JH, Kupa EJ. Portable pneumatic biventricular driver for the Thoratec ventricular assist device. ASAIO J 1997 43 : 631 4.
    • (1997) ASAIO J , vol.43 , pp. 631-634
    • Farrar, D.J.1    Buck, K.E.2    Coulter, J.H.3    Kupa, E.J.4
  • 3
    • 0032763407 scopus 로고    scopus 로고
    • A remote monitoring system for patients with implantable ventricular assist devices with a personal handy phone system
    • Okamoto E, Shimanaka M, Suzuki S, Baba K, Mitamura Y. A remote monitoring system for patients with implantable ventricular assist devices with a personal handy phone system. ASAIO J 1999 45 : 194 8.
    • (1999) ASAIO J , vol.45 , pp. 194-198
    • Okamoto, E.1    Shimanaka, M.2    Suzuki, S.3    Baba, K.4    Mitamura, Y.5
  • 4
    • 36248969383 scopus 로고    scopus 로고
    • Compact biventricular assist device with pneumatic actuation mechanism
    • Hwang CM, Nam KW, Lee JJ, et al. Compact biventricular assist device with pneumatic actuation mechanism. ASAIO J 2006 52 : 37A.
    • (2006) ASAIO J , vol.52
    • Hwang, C.M.1    Nam, K.W.2    Lee, J.J.3
  • 5
    • 33746814021 scopus 로고    scopus 로고
    • Ventricular assist device implantation using a right thoracotomy
    • Son HS, Sun K, Hwang CM, et al. Ventricular assist device implantation using a right thoracotomy. ASAIO J 2006 52 : 386 90.
    • (2006) ASAIO J , vol.52 , pp. 386-390
    • Son, H.S.1    Sun, K.2    Hwang, C.M.3
  • 6
    • 33845883552 scopus 로고    scopus 로고
    • Wireless patient monitoring system for a moving-actuator type artificial heart
    • Nam KW, Chung J, Choi SW, Sun K, Min BG. Wireless patient monitoring system for a moving-actuator type artificial heart. Int J Artif Organs 2006 29 : 973 80.
    • (2006) Int J Artif Organs , vol.29 , pp. 973-980
    • Nam, K.W.1    Chung, J.2    Choi, S.W.3    Sun, K.4    Min, B.G.5
  • 7
    • 0034573560 scopus 로고    scopus 로고
    • A new generation of remote data entry: Using WAP-phones in clinical trials
    • Eikemeier C, Grutter R, Heitmann K. A new generation of remote data entry: using WAP-phones in clinical trials. Stud Health Technol Inform 2000 77 : 338 42.
    • (2000) Stud Health Technol Inform , vol.77 , pp. 338-342
    • Eikemeier, C.1    Grutter, R.2    Heitmann, K.3
  • 8
    • 0037774678 scopus 로고    scopus 로고
    • Implementation of a WAP-based telemedicine system for patient monitoring. IEEE
    • Hung K, Zhang YT. Implementation of a WAP-based telemedicine system for patient monitoring. IEEE. Trans Inform Technol Biomed 2003 7 : 101 7.
    • (2003) Trans Inform Technol Biomed , vol.7 , pp. 101-107
    • Hung, K.1    Zhang, Y.T.2
  • 9
    • 33845905777 scopus 로고    scopus 로고
    • Self-management protocol for a moving-actuator type artificial heart
    • Nam KW, Chung J, Choi SW, Sun K, Min BG. Self-management protocol for a moving-actuator type artificial heart. Int J Artif Organs 2006 29 : 981 89.
    • (2006) Int J Artif Organs , vol.29 , pp. 981-989
    • Nam, K.W.1    Chung, J.2    Choi, S.W.3    Sun, K.4    Min, B.G.5
  • 11
    • 31444446088 scopus 로고    scopus 로고
    • Applying the ISO/IEEE 11073 standards to wearable home health monitoring systems
    • Yao J, Warren S. Applying the ISO/IEEE 11073 standards to wearable home health monitoring systems. J Clin Monit Comput 2005 19 : 427 36.
    • (2005) J Clin Monit Comput , vol.19 , pp. 427-436
    • Yao, J.1    Warren, S.2
  • 13
    • 0036675119 scopus 로고    scopus 로고
    • Negligible electromagnetic interaction between medical electronic equipment and 2.4 GHz band wireless LAN
    • Hanada E, Hoshino Y, Oyama H, Watanabe Y, Nose Y. Negligible electromagnetic interaction between medical electronic equipment and 2.4 GHz band wireless LAN. J Med Syst 2002 26 : 301 8.
    • (2002) J Med Syst , vol.26 , pp. 301-308
    • Hanada, E.1    Hoshino, Y.2    Oyama, H.3    Watanabe, Y.4    Nose, Y.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.