-
1
-
-
0033450732
-
Management of phenylketonuria for optimal outcome: A review of guidelines for phenylketonuria management and a report of surveys of parents, patients, and clinic directors
-
Wappner R, Cho S, Kronmal RA, Schuett V, et al. Management of phenylketonuria for optimal outcome: a review of guidelines for phenylketonuria management and a report of surveys of parents, patients, and clinic directors. Pediatrics 1999;104:e68.
-
(1999)
Pediatrics
, vol.104
-
-
Wappner, R.1
Cho, S.2
Kronmal, R.A.3
Schuett, V.4
-
2
-
-
0034675572
-
Phenylketonuria: Screening and Management
-
October 16-18
-
Phenylketonuria: Screening and Management: NIH Consensus Statement; October 16-18, 2000;17:1-27.
-
(2000)
NIH Consensus Statement
, vol.17
, pp. 1-27
-
-
-
3
-
-
0031046763
-
Maternal Phenylketonuria Collaborative Study (MPKUCS) offspring: Facial anomalies, malformations, and early neurological sequelae
-
Rouse B, Azen C, Koch R, Matalon R, et al. Maternal Phenylketonuria Collaborative Study (MPKUCS) offspring: facial anomalies, malformations, and early neurological sequelae. Am J Med Genet 1997;69:89-95.
-
(1997)
Am J Med Genet
, vol.69
, pp. 89-95
-
-
Rouse, B.1
Azen, C.2
Koch, R.3
Matalon, R.4
-
4
-
-
75449123150
-
A simple phenylalanine method for detecting phenylketonuria in large populations of newborn infants
-
Guthrie R, Susi A. A simple phenylalanine method for detecting phenylketonuria in large populations of newborn infants. Pediatrics 1963;32:338-343.
-
(1963)
Pediatrics
, vol.32
, pp. 338-343
-
-
Guthrie, R.1
Susi, A.2
-
5
-
-
0024423690
-
Fluorometric method for phenylalanine microplate assay adapted for phenylketonuria screening
-
Gerasimova NS, Steklova IV, Tuuminen T. Fluorometric method for phenylalanine microplate assay adapted for phenylketonuria screening. Clin Chem 1989;35:2112-2115.
-
(1989)
Clin Chem
, vol.35
, pp. 2112-2115
-
-
Gerasimova, N.S.1
Steklova, I.V.2
Tuuminen, T.3
-
6
-
-
0022501338
-
HPLC assay of phenylalanine and tyrosine in blood spots on filter paper
-
Roesel RA, Blankenship PR, Hommes FA. HPLC assay of phenylalanine and tyrosine in blood spots on filter paper. Clin Chim Acta 1986;156:91-96.
-
(1986)
Clin Chim Acta
, vol.156
, pp. 91-96
-
-
Roesel, R.A.1
Blankenship, P.R.2
Hommes, F.A.3
-
7
-
-
0023618929
-
Phenylalanine and tyrosine in serum and eluates from dried blood spots as determined by reversed-phase liquid chromatography
-
Rudy JL, Rutledge JC, Lewis SL. Phenylalanine and tyrosine in serum and eluates from dried blood spots as determined by reversed-phase liquid chromatography. Clin Chem 1987;33:1152-1154.
-
(1987)
Clin Chem
, vol.33
, pp. 1152-1154
-
-
Rudy, J.L.1
Rutledge, J.C.2
Lewis, S.L.3
-
8
-
-
0031648856
-
Use of phenylalanine-to-tyrosine ratio determined by tandem mass spectrometry to improve newborn screening for phenylketonuria of early discharge specimens collected in the first 24 hours
-
Chace DH, Sherwin JE, Hillman SL, Lorey F, et al. Use of phenylalanine-to-tyrosine ratio determined by tandem mass spectrometry to improve newborn screening for phenylketonuria of early discharge specimens collected in the first 24 hours. Clin Chem 1998;44:2405-2409.
-
(1998)
Clin Chem
, vol.44
, pp. 2405-2409
-
-
Chace, D.H.1
Sherwin, J.E.2
Hillman, S.L.3
Lorey, F.4
-
9
-
-
0029121111
-
Diagnosis of inborn errors of metabolism from blood spots by acylcarnitines and amino acids profiling using automated electrospray tandem mass spectrometry
-
Rashed MS, Ozand PT, Bucknall MP, Little D. Diagnosis of inborn errors of metabolism from blood spots by acylcarnitines and amino acids profiling using automated electrospray tandem mass spectrometry. Pediatr Res 1995;38:324-331.
-
(1995)
Pediatr Res
, vol.38
, pp. 324-331
-
-
Rashed, M.S.1
Ozand, P.T.2
Bucknall, M.P.3
Little, D.4
-
10
-
-
0036367077
-
Validation of the phenylalanine/tyrosine ratio determined by tandem mass spectrometry: Sensitive newborn screening for phenylketonuria
-
Ceglarek U, Muller P, Stach B, Buhrdel P, et al. Validation of the phenylalanine/tyrosine ratio determined by tandem mass spectrometry: sensitive newborn screening for phenylketonuria. Clin Chem Lab Med 2002;40:693-697.
-
(2002)
Clin Chem Lab Med
, vol.40
, pp. 693-697
-
-
Ceglarek, U.1
Muller, P.2
Stach, B.3
Buhrdel, P.4
-
11
-
-
0037639877
-
Expanded newborn screening for inborn errors of metabolism by electrospray ionization-tandem mass spectrometry: Results, outcome, and implications
-
Schulze A, Lindner M, Kohlmuller D, Olgemoller K, et al. Expanded newborn screening for inborn errors of metabolism by electrospray ionization-tandem mass spectrometry: results, outcome, and implications. Pediatrics 2003;111:1399-1406.
-
(2003)
Pediatrics
, vol.111
, pp. 1399-1406
-
-
Schulze, A.1
Lindner, M.2
Kohlmuller, D.3
Olgemoller, K.4
-
12
-
-
0034218476
-
Impact of a camp experience on phenylalanine levels, knowledge, attitudes, and health beliefs relevant to nutrition management of phenylketonuria in adolescent girls
-
Singh RH, Kable JA, Guerrero NV, Sullivan KM, et al. Impact of a camp experience on phenylalanine levels, knowledge, attitudes, and health beliefs relevant to nutrition management of phenylketonuria in adolescent girls. J Am Diet Assoc 2000;100:797-803.
-
(2000)
J Am Diet Assoc
, vol.100
, pp. 797-803
-
-
Singh, R.H.1
Kable, J.A.2
Guerrero, N.V.3
Sullivan, K.M.4
-
14
-
-
0027305020
-
Synthesis of a fluorescent derivatizing reagent, 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate, and its application for the analysis of hydrolysate amino acids via high-performance liquid chromatography
-
Cohen SA, Michaud DP. Synthesis of a fluorescent derivatizing reagent, 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate, and its application for the analysis of hydrolysate amino acids via high-performance liquid chromatography. Anal Biochem 1993;211:279-287.
-
(1993)
Anal Biochem
, vol.211
, pp. 279-287
-
-
Cohen, S.A.1
Michaud, D.P.2
-
15
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
16
-
-
0029118956
-
Evaluation of factors influencing precision in the analysis of samples taken from blood spots on filter paper
-
O'Broin SD, Kelleher BP, Gunter E. Evaluation of factors influencing precision in the analysis of samples taken from blood spots on filter paper. Clin Lab Haematol 1995;17:185-188.
-
(1995)
Clin Lab Haematol
, vol.17
, pp. 185-188
-
-
O'Broin, S.D.1
Kelleher, B.P.2
Gunter, E.3
-
17
-
-
0033961921
-
Recoveries of phenylalanine from two sets of dried-blood-spot reference materials: Prediction from hematocrit, spot volume, and paper matrix
-
Adam BW, Alexander JR, Smith SJ, Chace DH, et al. Recoveries of phenylalanine from two sets of dried-blood-spot reference materials: prediction from hematocrit, spot volume, and paper matrix. Clin Chem 2000;46:126-128.
-
(2000)
Clin Chem
, vol.46
, pp. 126-128
-
-
Adam, B.W.1
Alexander, J.R.2
Smith, S.J.3
Chace, D.H.4
-
18
-
-
4444271263
-
Determination of phenylalanine and tyrosine in dried blood specimens by ion-exchange chromatography using the Hitachi L-8800 analyzer
-
Allard P, Cowell LD, Zytkovicz TH, Korson MS, et al. Determination of phenylalanine and tyrosine in dried blood specimens by ion-exchange chromatography using the Hitachi L-8800 analyzer. Clin Biochem 2004;37:857-862.
-
(2004)
Clin Biochem
, vol.37
, pp. 857-862
-
-
Allard, P.1
Cowell, L.D.2
Zytkovicz, T.H.3
Korson, M.S.4
-
19
-
-
0037420705
-
Simultaneous measurement of phenylalanine and tyrosine in phenylketonuric plasma and dried blood by high-performance liquid chromatography
-
Dale Y, Mackey V, Mushi R, Nyanda A, et al. Simultaneous measurement of phenylalanine and tyrosine in phenylketonuric plasma and dried blood by high-performance liquid chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2003;788:1-8.
-
(2003)
J Chromatogr B Analyt Technol Biomed Life Sci
, vol.788
, pp. 1-8
-
-
Dale, Y.1
Mackey, V.2
Mushi, R.3
Nyanda, A.4
|