메뉴 건너뛰기




Volumn 6512, Issue PART 1, 2007, Pages

Automatic detection of abrupt patient motion in SPECT data acquisition

Author keywords

Image restoration and enhancement

Indexed keywords

ALGORITHMS; DATA ACQUISITION; IMAGE ENHANCEMENT; IMAGE RECONSTRUCTION; IMAGING TECHNIQUES; PATIENT TREATMENT;

EID: 36248953779     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.708375     Document Type: Conference Paper
Times cited : (6)

References (17)
  • 1
    • 10144242449 scopus 로고    scopus 로고
    • Incidence and characterization of patient motion in myocardial perfusion spect: Part 1
    • June
    • J. Wheat and G. Currie, "Incidence and characterization of patient motion in myocardial perfusion spect: Part 1," Journal of Nuclear Medicine Technology 32, pp. 60-65, June 2004.
    • (2004) Journal of Nuclear Medicine Technology , vol.32 , pp. 60-65
    • Wheat, J.1    Currie, G.2
  • 2
    • 0027396030 scopus 로고
    • A quantitative assessment of patient motion and its effect on myocardial perfusion SPECT images
    • E. H. Botvinick, Y. Y. Zhu, W. J. O'Connell, and M. W. Dae, "A quantitative assessment of patient motion and its effect on myocardial perfusion SPECT images," J Nucl Med 34(2), pp. 303-310, 1993.
    • (1993) J Nucl Med , vol.34 , Issue.2 , pp. 303-310
    • Botvinick, E.H.1    Zhu, Y.Y.2    O'Connell, W.J.3    Dae, M.W.4
  • 3
    • 0026655069 scopus 로고
    • Effect of patient motion on tomographic myocardial perfusion imaging
    • J. A. Cooper, P. H. Neumann, and B. K. McCandless, "Effect of patient motion on tomographic myocardial perfusion imaging," J Nucl Med 33(8), pp. 1566-1571, 1992.
    • (1992) J Nucl Med , vol.33 , Issue.8 , pp. 1566-1571
    • Cooper, J.A.1    Neumann, P.H.2    McCandless, B.K.3
  • 4
    • 0024447286 scopus 로고
    • upward creep of the heart: A frequent source of false-positive reversible defects during thallium201 stress-redistribution SPECT
    • J, Friedman, K. Van Train, J. Maddahi, A. Rozanski, F. Prigent, J. Bietendorf, A. Waxman, and D. S, Berman, ""upward creep" of the heart: A frequent source of false-positive reversible defects during thallium201 stress-redistribution SPECT," J Nucl Med 30(10), pp. 1718-1722, 1989.
    • (1989) J Nucl Med , vol.30 , Issue.10 , pp. 1718-1722
    • Friedman, J.1    Van Train, K.2    Maddahi, J.3    Rozanski, A.4    Prigent, F.5    Bietendorf, J.6    Waxman, A.7    Berman, D.S.8
  • 6
    • 0029226302 scopus 로고
    • Patient motion correction of SPECT images: Dual scan approach
    • 94, Norfolk, VA 3, pp
    • A. M. Passalaqua and R. Narayanaswamy, "Patient motion correction of SPECT images: dual scan approach," IEEE Proc. NSSS'94, Norfolk, VA 3, pp. 1270-1274, 1995.
    • (1995) IEEE Proc. NSSS , pp. 1270-1274
    • Passalaqua, A.M.1    Narayanaswamy, R.2
  • 7
    • 0031938747 scopus 로고    scopus 로고
    • Use of forward projection to correct patient motion during SPECT imaging
    • K. J. Lee and D, C. Barber, "Use of forward projection to correct patient motion during SPECT imaging," Phys Med Biol 43, pp. 171-187, 1998.
    • (1998) Phys Med Biol , vol.43 , pp. 171-187
    • Lee, K.J.1    Barber, D.C.2
  • 9
    • 0033311379 scopus 로고    scopus 로고
    • A practical 3D tomographic method for correcting patient head motion in clinical SPECT
    • R. R. Fulton, S. Eberl, S. R. Meikle, B. F. Hutton, and M. Braun, "A practical 3D tomographic method for correcting patient head motion in clinical SPECT," IEEE Trans Nucl Sci 46(3), pp. 667-672, 1999.
    • (1999) IEEE Trans Nucl Sci , vol.46 , Issue.3 , pp. 667-672
    • Fulton, R.R.1    Eberl, S.2    Meikle, S.R.3    Hutton, B.F.4    Braun, M.5
  • 11
    • 38149014351 scopus 로고    scopus 로고
    • A new approach for motion correction in spect imaging
    • Springer. Accepted for publication
    • H. Schumacher and B. Fischer, "A new approach for motion correction in spect imaging," in In Bildverarbeitung für die Medizin. Springer. Accepted for publication., 2007.
    • (2007) In Bildverarbeitung für die Medizin
    • Schumacher, H.1    Fischer, B.2
  • 14
    • 0036464430 scopus 로고    scopus 로고
    • A hybrid 3-d reconstruction/registration algorithm for correction of head motion in emission tomography
    • February
    • B. F. Hutton, A. Z. Kyme, Y. H. Lau, D. W. Skerrett, and R. Fulton, "A hybrid 3-d reconstruction/registration algorithm for correction of head motion in emission tomography," IEEE Transaction on Nuclear Science 49, pp. 188-194, February 2002.
    • (2002) IEEE Transaction on Nuclear Science , vol.49 , pp. 188-194
    • Hutton, B.F.1    Kyme, A.Z.2    Lau, Y.H.3    Skerrett, D.W.4    Fulton, R.5
  • 17
    • 0023833767 scopus 로고
    • Quantitative analysis of the tomographic thallium-201 myocardial bullseye display: Critical role of correcting for patient motion
    • January
    • R. Eisner, A. Churchwell, T. Noever, and et al., "Quantitative analysis of the tomographic thallium-201 myocardial bullseye display: Critical role of correcting for patient motion," Journal of Nuclear Medicine Technology 29, pp. 91-97, January 1988.
    • (1988) Journal of Nuclear Medicine Technology , vol.29 , pp. 91-97
    • Eisner, R.1    Churchwell, A.2    Noever, T.3    and et, al.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.