1
-
-
62349096125
-
-
Available online at:, December
-
Spielberg, M., Randelzhofer, P., Moctezuma B., Gläser, R., Kurtz, C. and Strub, J.R., 2001, Image-Guided Oral Implantology. Available online at: http://www.worlddent.com/2001/05/articles/strubj.xml (December 2006).
-
(2001)
Image-Guided Oral Implantology
-
-
Spielberg, M.1
Randelzhofer, P.2
Moctezuma, B.3
Gläser, R.4
Kurtz, C.5
Strub, J.R.6
-
2
-
-
0029395654
-
Dental implant treatment planning with reformatted computed tomography
-
Besimo, C., Lambrecht, J.T., Nidecker, A., 1995, Dental implant treatment planning with reformatted computed tomography. Dentomaxillofac Radiol., 24, 264-267.
-
(1995)
Dentomaxillofac Radiol
, vol.24
, pp. 264-267
-
-
Besimo, C.1
Lambrecht, J.T.2
Nidecker, A.3
-
3
-
-
0029421436
-
Computer assisted dental implant surgery using computed tomography
-
Fortin, T., Coudert, J.L., Champleboux G., Sautot, P., Lavallee, S., 1995, Computer assisted dental implant surgery using computed tomography. J Image Guided Surg, 1, 53-58.
-
(1995)
J Image Guided Surg
, vol.1
, pp. 53-58
-
-
Fortin, T.1
Coudert, J.L.2
Champleboux, G.3
Sautot, P.4
Lavallee, S.5
-
4
-
-
0031032378
-
Effects of aging on titanium implants inserted into the tibiae of female rats using light microscopy, SEM, and image processing
-
Takeshita, F., Murai, K., Ayukawa, Y., Suetsugu, T., 1997, Effects of aging on titanium implants inserted into the tibiae of female rats using light microscopy, SEM, and image processing. J Biomed Mater Res., 34, 1-8.
-
(1997)
J Biomed Mater Res
, vol.34
, pp. 1-8
-
-
Takeshita, F.1
Murai, K.2
Ayukawa, Y.3
Suetsugu, T.4
-
5
-
-
0027872438
-
The prevalence of altered sensation associated with implant surgery
-
Ellies, L.G. and Hawker, P.B., 1993, The prevalence of altered sensation associated with implant surgery. International Journal of Oral and Maxillofacial Implants, 8, 674-679.
-
(1993)
International Journal of Oral and Maxillofacial Implants
, vol.8
, pp. 674-679
-
-
Ellies, L.G.1
Hawker, P.B.2
-
6
-
-
8444245553
-
Computer-guided insertion of dental implants - a clinical evaluation
-
Brief, J., Hassfeld, S., Sonnenfeld, U., Persky, N., Krempien, R., Treiber, M. and Muhling, J., 2001, Computer-guided insertion of dental implants - a clinical evaluation. International Congress Series, 1230, 739-747.
-
(2001)
International Congress Series
, vol.1230
, pp. 739-747
-
-
Brief, J.1
Hassfeld, S.2
Sonnenfeld, U.3
Persky, N.4
Krempien, R.5
Treiber, M.6
Muhling, J.7
-
7
-
-
0034305454
-
Can implants be correctly angulated based on surgical templates used for osseointegrated dental implants?
-
Naitoh, M., Ariji, E., Okumura, S., Ohsaki, C., Kurita, K. and Ishigami, T., 2000, Can implants be correctly angulated based on surgical templates used for osseointegrated dental implants? Clinical Oral Implants Research, 11, 409-414.
-
(2000)
Clinical Oral Implants Research
, vol.11
, pp. 409-414
-
-
Naitoh, M.1
Ariji, E.2
Okumura, S.3
Ohsaki, C.4
Kurita, K.5
Ishigami, T.6
-
8
-
-
8344260048
-
In vitro assessment of a registration protocol for image guided implant dentistry
-
Birkfellner, W., Solar, P., Gahleitner, A., Huber, K., Kainberger, F., Kettenbach, J., Homolka, P., Diemling, M., Watzek, G. and Bergmann, H., 2001, In vitro assessment of a registration protocol for image guided implant dentistry. Clinical Oral Implants Research, 12, 69-78.
-
(2001)
Clinical Oral Implants Research
, vol.12
, pp. 69-78
-
-
Birkfellner, W.1
Solar, P.2
Gahleitner, A.3
Huber, K.4
Kainberger, F.5
Kettenbach, J.6
Homolka, P.7
Diemling, M.8
Watzek, G.9
Bergmann, H.10
-
9
-
-
0000101380
-
Marching cubes: A high resolution 3D surface construction algorithm
-
Lorensen, W.E. and Cline, H.E., 1987, Marching cubes: A high resolution 3D surface construction algorithm. ACM Computer Graphics, 21, 38-44.
-
(1987)
ACM Computer Graphics
, vol.21
, pp. 38-44
-
-
Lorensen, W.E.1
Cline, H.E.2
-
10
-
-
0026891311
-
Decimation of triangle meshes
-
Schroeder, W.J., Zarge, J.A. and Lorensen, W.E., 1992, Decimation of triangle meshes. Proceedings ACMM Siggraph, 26, 65-70.
-
(1992)
Proceedings ACMM Siggraph
, vol.26
, pp. 65-70
-
-
Schroeder, W.J.1
Zarge, J.A.2
Lorensen, W.E.3
-
11
-
-
0002375331
-
Registration for computer-integrated surgery: Methodology, state of the art
-
R.H. Taylor, S. Lavallee, G.G. Burdea and R. Mosges Eds, Cambridge, MA: MIT Press, pp
-
Lavallee, S., 1995, Registration for computer-integrated surgery: Methodology, state of the art. In: R.H. Taylor, S. Lavallee, G.G. Burdea and R. Mosges (Eds) Computer-Integrated Surgery (Cambridge, MA: MIT Press), pp. 77-97.
-
(1995)
Computer-Integrated Surgery
, pp. 77-97
-
-
Lavallee, S.1
-
12
-
-
0035437717
-
The distribution of target registration error in rigid-body point-based registration
-
Fitzpatrick, J.M. and West, J.B., 2001, The distribution of target registration error in rigid-body point-based registration. IEEE Transactions on Medical Imaging, 20, 917-927.
-
(2001)
IEEE Transactions on Medical Imaging
, vol.20
, pp. 917-927
-
-
Fitzpatrick, J.M.1
West, J.B.2
-
13
-
-
0032173357
-
Anatomy-based registration of CT-scan and intraoperative X-ray images for guiding a surgical robot
-
Gueziec, A., Kazanzides, P., Williamson, B. and Taylor, R.H., 1998, Anatomy-based registration of CT-scan and intraoperative X-ray images for guiding a surgical robot. IEEE Transactions on Medical Imaging, 17, 715-728.
-
(1998)
IEEE Transactions on Medical Imaging
, vol.17
, pp. 715-728
-
-
Gueziec, A.1
Kazanzides, P.2
Williamson, B.3
Taylor, R.H.4
-
14
-
-
0032129157
-
comparison of similarity measures for use in 2-D-3-D medical image registration
-
Penney, G.P., Weese, J., Little, J.A., Desmedt, P., Hill, D.L.G. and Hawkes, D.J.A., 1998, comparison of similarity measures for use in 2-D-3-D medical image registration. IEEE Transactions on Medical Imaging, 17, 586-595.
-
(1998)
IEEE Transactions on Medical Imaging
, vol.17
, pp. 586-595
-
-
Penney, G.P.1
Weese, J.2
Little, J.A.3
Desmedt, P.4
Hill, D.L.G.5
Hawkes, D.J.A.6
-
15
-
-
0032173371
-
Surface-based registration of CT images to physical space for image-guided surgery of the spine: A sensitivity study
-
Herring, J.L., Dawant, B.M., Maurer, Jr, C.R., Muratore, D.M., Galloway, R.L. and Fitzpatrick, J.M., 1998, Surface-based registration of CT images to physical space for image-guided surgery of the spine: A sensitivity study. IEEE Transactions on Medical Imaging, 17, 743-752.
-
(1998)
IEEE Transactions on Medical Imaging
, vol.17
, pp. 743-752
-
-
Herring, J.L.1
Dawant, B.M.2
Maurer Jr, C.R.3
Muratore, D.M.4
Galloway, R.L.5
Fitzpatrick, J.M.6
-
16
-
-
0022362613
-
Prism representation: A 3D ray-tracing algorithm for radiotherapy applications
-
Siddon, R.L., 1985, Prism representation: a 3D ray-tracing algorithm for radiotherapy applications. Physics in Medicine and Biology, 30, 817-824.
-
(1985)
Physics in Medicine and Biology
, vol.30
, pp. 817-824
-
-
Siddon, R.L.1
-
17
-
-
0026821209
-
A method for registration of 3D shapes
-
Besl, P.J. and Mckay, N.D., 1992, A method for registration of 3D shapes. IEEE Transactions on Pattern Analysis and Machine Intelligence, 14, 239-256.
-
(1992)
IEEE Transactions on Pattern Analysis and Machine Intelligence
, vol.14
, pp. 239-256
-
-
Besl, P.J.1
Mckay, N.D.2
-
18
-
-
33846940893
-
-
PhD thesis, University of Vienna, Vienna, Austria
-
Fakultat, M., 2002. Image guided endosonography requirements and development, PhD thesis, University of Vienna, Vienna, Austria.
-
(2002)
Image guided endosonography requirements and development
-
-
Fakultat, M.1
-
19
-
-
0041380912
-
Computer-aided placement of andosseous oral implants in patients after ablative tumour surgery: Assessment of accuracy
-
Wagner, A., Wanschitz, F., Birkfellner, W., Zauza, K., Klug, C., Schicko, K., Kainberger, F., Czerny, C., Bergmann, H., Ewers, R., 2003, Computer-aided placement of andosseous oral implants in patients after ablative tumour surgery: assessment of accuracy. Clin Oral Implants Res., 14, 340-348.
-
(2003)
Clin Oral Implants Res
, vol.14
, pp. 340-348
-
-
Wagner, A.1
Wanschitz, F.2
Birkfellner, W.3
Zauza, K.4
Klug, C.5
Schicko, K.6
Kainberger, F.7
Czerny, C.8
Bergmann, H.9
Ewers, R.10
-
20
-
-
0036974768
-
Computer-enhanced stereoscopic vision in a head-mounted display for oral implant surgery
-
Wanschitz, F., Birkfellner, W., Figl, M., Patruta, S., Wagner, A., Watzinger, F., Yerit, K., Schicho, K., Hanel, R., Kainberger, F., Imhof, H., Bergmann, H., Ewers, R., 2002, Computer-enhanced stereoscopic vision in a head-mounted display for oral implant surgery. Clinical Oral Implants Research, 13, 610-616.
-
(2002)
Clinical Oral Implants Research
, vol.13
, pp. 610-616
-
-
Wanschitz, F.1
Birkfellner, W.2
Figl, M.3
Patruta, S.4
Wagner, A.5
Watzinger, F.6
Yerit, K.7
Schicho, K.8
Hanel, R.9
Kainberger, F.10
Imhof, H.11
Bergmann, H.12
Ewers, R.13
|