메뉴 건너뛰기




Volumn 104, Issue 6, 2007, Pages 752-756

Biomechanical comparison of different plating techniques in repair of mandibular angle fractures

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL; ARTICLE; BIOMECHANICS; BONE PLATE; COMPRESSIVE STRENGTH; DENTAL CARE; INSTRUMENTATION; MANDIBLE FRACTURE; MASTICATION; OSTEOSYNTHESIS; SHEEP;

EID: 36149001773     PISSN: 10792104     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.tripleo.2007.03.014     Document Type: Article
Times cited : (74)

References (27)
  • 1
    • 21244464835 scopus 로고    scopus 로고
    • Comparison of strains produced by titanium and poly D,L-lactide acid plating systems to in vitro forces
    • Chacon G.U., Dillard F., Clelland N., and Rashid R. Comparison of strains produced by titanium and poly D,L-lactide acid plating systems to in vitro forces. J Oral Maxillofac Surg 63 (2005) 968-972
    • (2005) J Oral Maxillofac Surg , vol.63 , pp. 968-972
    • Chacon, G.U.1    Dillard, F.2    Clelland, N.3    Rashid, R.4
  • 3
    • 0033169243 scopus 로고    scopus 로고
    • Treatment methods for fractures of the mandibular angle
    • Ellis III E. Treatment methods for fractures of the mandibular angle. Int J Oral Maxillofac Surg 28 (1999) 243-252
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 243-252
    • Ellis III, E.1
  • 4
    • 12844283458 scopus 로고    scopus 로고
    • Fixation of mandibular angle fractures with a 2.0 mm 3-dimentional curved angle strut plate
    • Guimond C., Johnson J.V., and Marchena J.M. Fixation of mandibular angle fractures with a 2.0 mm 3-dimentional curved angle strut plate. J Oral Maxillofac Surg 63 (2005) 209-214
    • (2005) J Oral Maxillofac Surg , vol.63 , pp. 209-214
    • Guimond, C.1    Johnson, J.V.2    Marchena, J.M.3
  • 5
    • 0242319477 scopus 로고    scopus 로고
    • Analysis of complications in fractures of the mandibular angle: a study with finite element computation and evaluation of data of 277 patients
    • Feller K.U., Schneider M., Hlawitschka M., Pfeifer G., Lauer G., and Eckelt U. Analysis of complications in fractures of the mandibular angle: a study with finite element computation and evaluation of data of 277 patients. J Craniomaxillofac Surg 31 (2003) 290-295
    • (2003) J Craniomaxillofac Surg , vol.31 , pp. 290-295
    • Feller, K.U.1    Schneider, M.2    Hlawitschka, M.3    Pfeifer, G.4    Lauer, G.5    Eckelt, U.6
  • 6
    • 33846380315 scopus 로고    scopus 로고
    • Biomechanical comparison of plating techniques for fractures of the mandibular condyle
    • Alkan A., Metin M., Muglali M., Ozden B., and Celebi N. Biomechanical comparison of plating techniques for fractures of the mandibular condyle. Br J Oral Maxillofac Surg 45 (2007) 145-149
    • (2007) Br J Oral Maxillofac Surg , vol.45 , pp. 145-149
    • Alkan, A.1    Metin, M.2    Muglali, M.3    Ozden, B.4    Celebi, N.5
  • 7
    • 33746088811 scopus 로고    scopus 로고
    • In vitro comparison of biomechanical characteristics of sagittal split osteotomy fixation techniques
    • Özden B., Alkan A., Ari{dotless}ci{dotless} S., and Erdem E. In vitro comparison of biomechanical characteristics of sagittal split osteotomy fixation techniques. Int J Oral Maxillofac Surg 35 (2006) 837-841
    • (2006) Int J Oral Maxillofac Surg , vol.35 , pp. 837-841
    • Özden, B.1    Alkan, A.2    Arici, S.3    Erdem, E.4
  • 8
    • 14944348462 scopus 로고    scopus 로고
    • Treatment of mandibular angle fractures with a matrix miniplate: a preliminary report
    • discussion 1717-8
    • Feledy J., Caterson E.J., Steger S., Stal S., and Hollier L. Treatment of mandibular angle fractures with a matrix miniplate: a preliminary report. Plast Reconstr Surg 114 (2004) 1711-1716 discussion 1717-8
    • (2004) Plast Reconstr Surg , vol.114 , pp. 1711-1716
    • Feledy, J.1    Caterson, E.J.2    Steger, S.3    Stal, S.4    Hollier, L.5
  • 9
  • 10
    • 0034786799 scopus 로고    scopus 로고
    • A biomechanical evaluation of mandibular angle fracture plating techniques
    • Haug R.H., Fattahi T.T., and Goltz M. A biomechanical evaluation of mandibular angle fracture plating techniques. J Oral Maxillofac Surg 59 (2001) 1199-1210
    • (2001) J Oral Maxillofac Surg , vol.59 , pp. 1199-1210
    • Haug, R.H.1    Fattahi, T.T.2    Goltz, M.3
  • 11
    • 0036843737 scopus 로고    scopus 로고
    • Does plate adaptation affect stability?. A biomechanical comparison of locking and nonlocking plates
    • Haug R.H., Street C.C., and Goltz M. Does plate adaptation affect stability?. A biomechanical comparison of locking and nonlocking plates. J Oral Maxillofac Surg 60 (2002) 1319-1326
    • (2002) J Oral Maxillofac Surg , vol.60 , pp. 1319-1326
    • Haug, R.H.1    Street, C.C.2    Goltz, M.3
  • 12
    • 0036140978 scopus 로고    scopus 로고
    • A biomechanical evaluation of mandibular condyle fracture plating techniques
    • Haug R.H., Peterson G.P., and Goltz M. A biomechanical evaluation of mandibular condyle fracture plating techniques. J Oral Maxillofac Surg 60 (2002) 73-80
    • (2002) J Oral Maxillofac Surg , vol.60 , pp. 73-80
    • Haug, R.H.1    Peterson, G.P.2    Goltz, M.3
  • 13
    • 1642444702 scopus 로고    scopus 로고
    • Comparison of stability of absorbable and titanium plate and screw fixation for sagittal split ramus osteotomy
    • Dolanmaz D., Uckan S., Isik K., and Saglam H. Comparison of stability of absorbable and titanium plate and screw fixation for sagittal split ramus osteotomy. Br J Oral Maxillofac Surg 42 (2004) 127-132
    • (2004) Br J Oral Maxillofac Surg , vol.42 , pp. 127-132
    • Dolanmaz, D.1    Uckan, S.2    Isik, K.3    Saglam, H.4
  • 14
    • 0027015701 scopus 로고
    • In vitro comparison of screw versus plate fixation in the sagittal split osteotomy
    • Foley W.L., and Beckman T.W. In vitro comparison of screw versus plate fixation in the sagittal split osteotomy. Int J Adult Orthodont Orthognath Surg 7 (1992) 147-151
    • (1992) Int J Adult Orthodont Orthognath Surg , vol.7 , pp. 147-151
    • Foley, W.L.1    Beckman, T.W.2
  • 15
    • 0031877169 scopus 로고    scopus 로고
    • Plating techniques and plate orientation in repair of mandibular angle fractures: an in vitro study
    • Fedok F.G., Van Kooten D.W., DeJoseph L.M., McGinn J.D., Sobota B., Levin R.J., et al. Plating techniques and plate orientation in repair of mandibular angle fractures: an in vitro study. Laryngoscope 108 (1998) 1218-1224
    • (1998) Laryngoscope , vol.108 , pp. 1218-1224
    • Fedok, F.G.1    Van Kooten, D.W.2    DeJoseph, L.M.3    McGinn, J.D.4    Sobota, B.5    Levin, R.J.6
  • 16
    • 0035083951 scopus 로고    scopus 로고
    • Bite forces after open or closed treatment of mandibular condylar process fractures
    • Ellis E., and Throckmorton G.S. Bite forces after open or closed treatment of mandibular condylar process fractures. J Oral Maxillofac Surg 59 (2001) 389-395
    • (2001) J Oral Maxillofac Surg , vol.59 , pp. 389-395
    • Ellis, E.1    Throckmorton, G.S.2
  • 17
    • 0030499203 scopus 로고    scopus 로고
    • Improvement of maximum occlusal forces after orthognathic surgery
    • Throckmorton G.S., Bushang P.H., and Ellis E. Improvement of maximum occlusal forces after orthognathic surgery. J Oral Maxillofac Surg 54 (1996) 1080-1086
    • (1996) J Oral Maxillofac Surg , vol.54 , pp. 1080-1086
    • Throckmorton, G.S.1    Bushang, P.H.2    Ellis, E.3
  • 18
    • 0028361176 scopus 로고
    • Bite forces in patients treated for mandibular angle fractures
    • Tate G.S., Ellis E., and Throckmorton G.S. Bite forces in patients treated for mandibular angle fractures. J Oral Maxillofac Surg 52 (1994) 734-736
    • (1994) J Oral Maxillofac Surg , vol.52 , pp. 734-736
    • Tate, G.S.1    Ellis, E.2    Throckmorton, G.S.3
  • 19
    • 0030039058 scopus 로고    scopus 로고
    • Bite forces before and after surgical correction of mandibular prognathism
    • Ellis E., Throckmorton G.S., and Sinn D.P. Bite forces before and after surgical correction of mandibular prognathism. J Oral Maxillofac Surg 54 (1996) 176-181
    • (1996) J Oral Maxillofac Surg , vol.54 , pp. 176-181
    • Ellis, E.1    Throckmorton, G.S.2    Sinn, D.P.3
  • 20
    • 0017045214 scopus 로고
    • Mandibular synthesis. Placement of the synthesis as a function of mandibular stress
    • Champy M., and Lodde J.P. Mandibular synthesis. Placement of the synthesis as a function of mandibular stress. Rev Stomatol Chir Maxillofac 77 (1976) 971-976
    • (1976) Rev Stomatol Chir Maxillofac , vol.77 , pp. 971-976
    • Champy, M.1    Lodde, J.P.2
  • 22
    • 0030484931 scopus 로고    scopus 로고
    • Treatment of mandibular angle fractures using one noncompression miniplate
    • Ellis III E., and Walker L.R. Treatment of mandibular angle fractures using one noncompression miniplate. J Oral Maxillofac Surg 54 (1996) 864-871
    • (1996) J Oral Maxillofac Surg , vol.54 , pp. 864-871
    • Ellis III, E.1    Walker, L.R.2
  • 23
    • 0033051024 scopus 로고    scopus 로고
    • Treatment of mandibular angle fractures with a malleable noncompression miniplate
    • discussion 292-3
    • Potter J., and Ellis III E. Treatment of mandibular angle fractures with a malleable noncompression miniplate. J Oral Maxillofac Surg 57 (1999) 288-292 discussion 292-3
    • (1999) J Oral Maxillofac Surg , vol.57 , pp. 288-292
    • Potter, J.1    Ellis III, E.2
  • 24
    • 0035089387 scopus 로고    scopus 로고
    • Technique for applying 2 miniplates for treatment of mandibular angle fractures
    • Choi B.H., and Suh C.H. Technique for applying 2 miniplates for treatment of mandibular angle fractures. J Oral Maxillofac Surg 59 (2001) 353-354
    • (2001) J Oral Maxillofac Surg , vol.59 , pp. 353-354
    • Choi, B.H.1    Suh, C.H.2
  • 25
    • 0028930259 scopus 로고
    • Stability testing of a two miniplate fixation technique for mandibular angle fractures. An in vitro study
    • Choi B.H., Yoo J.H., Kim K.N., and Kang H.S. Stability testing of a two miniplate fixation technique for mandibular angle fractures. An in vitro study. J Craniomaxillofac Surg 23 (1995) 123-125
    • (1995) J Craniomaxillofac Surg , vol.23 , pp. 123-125
    • Choi, B.H.1    Yoo, J.H.2    Kim, K.N.3    Kang, H.S.4
  • 26
    • 0028144345 scopus 로고
    • Testing biomechanical strength of repairs for the mandibular angle fracture
    • Dichard A., and Klotch D.W. Testing biomechanical strength of repairs for the mandibular angle fracture. Laryngoscope 104 (1994) 201-208
    • (1994) Laryngoscope , vol.104 , pp. 201-208
    • Dichard, A.1    Klotch, D.W.2
  • 27
    • 0027968818 scopus 로고
    • Treatment of mandibular angle fractures using two noncompression miniplates
    • Ellis III E., and Walker L. Treatment of mandibular angle fractures using two noncompression miniplates. Int J Oral Maxillofac Surg 52 (1994) 1032-1036
    • (1994) Int J Oral Maxillofac Surg , vol.52 , pp. 1032-1036
    • Ellis III, E.1    Walker, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.