-
1
-
-
84944817192
-
On the regulation of blood supply of the brain
-
Roy, C.S., Sherrington, C.S., On the regulation of blood supply of the brain. J. Physiol. 1 (1890), 85-108.
-
(1890)
J. Physiol.
, vol.1
, pp. 85-108
-
-
Roy, C.S.1
Sherrington, C.S.2
-
2
-
-
0025630001
-
Brain magnetic resonance imaging with contrast dependent on blood oxygenation
-
Ogawa, S, et al. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc. Natl. Acad. Sci. U. S. A. 87 (1990), 9868-9872.
-
(1990)
Proc. Natl. Acad. Sci. U. S. A.
, vol.87
, pp. 9868-9872
-
-
Ogawa, S.1
-
3
-
-
0001106690
-
Circulatory and metabolic correlates of brain function in normal humans
-
American Physiological Society Bethesda
-
Raichle, M.E., Circulatory and metabolic correlates of brain function in normal humans. Handbook of Physiology—The Nervous System, 1987, American Physiological Society, Bethesda, 643-674.
-
(1987)
Handbook of Physiology—The Nervous System
, pp. 643-674
-
-
Raichle, M.E.1
-
4
-
-
0025336246
-
Oxygenation-sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
-
Ogawa, S, et al. Oxygenation-sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields. Magn. Reson. Med. 14 (1990), 68-78.
-
(1990)
Magn. Reson. Med.
, vol.14
, pp. 68-78
-
-
Ogawa, S.1
-
5
-
-
0034662965
-
Functional MRI at 1.5 tesla: a comparison of the blood oxygenation level-dependent signal and electrophysiology
-
Disbrow, E.A., et al. Functional MRI at 1.5 tesla: a comparison of the blood oxygenation level-dependent signal and electrophysiology. Proc. Natl. Acad. Sci. U. S. A. 97 (2000), 9718-9723.
-
(2000)
Proc. Natl. Acad. Sci. U. S. A.
, vol.97
, pp. 9718-9723
-
-
Disbrow, E.A.1
-
6
-
-
0036802642
-
Insights into new techniques for high resolution functional MRI
-
Kim, S.-G., Ogawa, S, Insights into new techniques for high resolution functional MRI. Curr. Opin. Neurobiol. 12 (2002), 607-615.
-
(2002)
Curr. Opin. Neurobiol.
, vol.12
, pp. 607-615
-
-
Kim, S.-G.1
Ogawa, S.2
-
7
-
-
0037402927
-
High-resolution functional magentic resonance imaging of the animal brain
-
Kim, S.-G., Ugurbil, K, High-resolution functional magentic resonance imaging of the animal brain. Methods 30 (2003), 28-41.
-
(2003)
Methods
, vol.30
, pp. 28-41
-
-
Kim, S.-G.1
Ugurbil, K.2
-
8
-
-
0029846966
-
Neuronal units linked to microvascular modules in cerebral cortex: response elements for imaging the brain
-
Woolsey, T.A., et al. Neuronal units linked to microvascular modules in cerebral cortex: response elements for imaging the brain. Cereb. Cortex 6 (1996), 647-660.
-
(1996)
Cereb. Cortex
, vol.6
, pp. 647-660
-
-
Woolsey, T.A.1
-
9
-
-
0019847644
-
Cortical blood vessels of the human brain
-
Duvernoy, H, Delon, S, Vannson, J, Cortical blood vessels of the human brain. Brain Res. Brain 7 (1981), 519-579.
-
(1981)
Brain Res. Brain
, vol.7
, pp. 519-579
-
-
Duvernoy, H.1
Delon, S.2
Vannson, J.3
-
10
-
-
0019421324
-
Quantitative capillary topography and blood flow in the cerebral cortex of cats: an in vivo microscopic study
-
Pawlik, G, Rackl, A, Bing, R.J., Quantitative capillary topography and blood flow in the cerebral cortex of cats: an in vivo microscopic study. Brain Res. 208 (1981), 35-58.
-
(1981)
Brain Res.
, vol.208
, pp. 35-58
-
-
Pawlik, G.1
Rackl, A.2
Bing, R.J.3
-
11
-
-
0027299106
-
Parenchymal microvascular systems and cerebral atrophy in spontaneously hypertensive rats
-
Gesztelyi, G, et al. Parenchymal microvascular systems and cerebral atrophy in spontaneously hypertensive rats. Brain Res. 61 (1993), 249-257.
-
(1993)
Brain Res.
, vol.61
, pp. 249-257
-
-
Gesztelyi, G.1
-
12
-
-
0034006090
-
In vivo MR measurements of regional arterial and venous blood volume fractions in intact rat brain
-
Duong, T.Q., Kim, S.-G., In vivo MR measurements of regional arterial and venous blood volume fractions in intact rat brain. Magn. Reson. Med. 43 (2000), 393-402.
-
(2000)
Magn. Reson. Med.
, vol.43
, pp. 393-402
-
-
Duong, T.Q.1
Kim, S.-G.2
-
13
-
-
0035033892
-
Relative changes of cerebral arterial and venous blood volumes during increased cerebral blood flow: implications for BOLD fMRI
-
Lee, S.-P., et al. Relative changes of cerebral arterial and venous blood volumes during increased cerebral blood flow: implications for BOLD fMRI. Magn. Reson. Med. 45 (2001), 791-800.
-
(2001)
Magn. Reson. Med.
, vol.45
, pp. 791-800
-
-
Lee, S.-P.1
-
14
-
-
0023780085
-
Nonoxidative glucose consumption during focal physiologic neural activity
-
Fox, P.T., et al. Nonoxidative glucose consumption during focal physiologic neural activity. Science 241 (1988), 462-464.
-
(1988)
Science
, vol.241
, pp. 462-464
-
-
Fox, P.T.1
-
15
-
-
0342963103
-
Focal physiological uncoupling of cerebral blood flow and oxidative metabolism during somatosensory stimulation in human subjects
-
Fox, P.T., Raichle, M.E., Focal physiological uncoupling of cerebral blood flow and oxidative metabolism during somatosensory stimulation in human subjects. Proc. Natl. Acad. Sci. U. S. A. 83 (1986), 1140-1144.
-
(1986)
Proc. Natl. Acad. Sci. U. S. A.
, vol.83
, pp. 1140-1144
-
-
Fox, P.T.1
Raichle, M.E.2
-
16
-
-
0035845504
-
Localized cerebral blood flow response at submillimeter columnar resolution
-
Duong, T.Q., et al. Localized cerebral blood flow response at submillimeter columnar resolution. Proc. Natl. Acad. Sci. U. S. A. 98 (2001), 10904-10909.
-
(2001)
Proc. Natl. Acad. Sci. U. S. A.
, vol.98
, pp. 10904-10909
-
-
Duong, T.Q.1
-
17
-
-
0029997609
-
Interactions between electrical activity and cortical microcirculation revealed by imaging spectroscopy: implication for functional brain mapping
-
Malonek, D, Grinvald, A, Interactions between electrical activity and cortical microcirculation revealed by imaging spectroscopy: implication for functional brain mapping. Science 272 (1996), 551-554.
-
(1996)
Science
, vol.272
, pp. 551-554
-
-
Malonek, D.1
Grinvald, A.2
-
18
-
-
0026508892
-
Perfusion imaging
-
Detre, J.A., et al. Perfusion imaging. Magn. Reson. Med. 23 (1992), 37-45.
-
(1992)
Magn. Reson. Med.
, vol.23
, pp. 37-45
-
-
Detre, J.A.1
-
19
-
-
0031022848
-
Correction for vascular artifacts in cerebral blood flow values by using arterial spin tagging techniques
-
Ye, F.Q., et al. Correction for vascular artifacts in cerebral blood flow values by using arterial spin tagging techniques. Magn. Reson. Med. 37 (1997), 226-235.
-
(1997)
Magn. Reson. Med.
, vol.37
, pp. 226-235
-
-
Ye, F.Q.1
-
20
-
-
0030851658
-
Evidence for the exchange of arterial spin-labeled water with tissue water in rat brain from diffusion-sensitized measurements of perfusion
-
Silva, A, Williams, D, Koretsky, A, Evidence for the exchange of arterial spin-labeled water with tissue water in rat brain from diffusion-sensitized measurements of perfusion. Magn. Reson. Med. 38 (1997), 232-237.
-
(1997)
Magn. Reson. Med.
, vol.38
, pp. 232-237
-
-
Silva, A.1
Williams, D.2
Koretsky, A.3
-
21
-
-
0033502655
-
Simultaneous BOLD and perfusion functional MRI during forepaw stimulation in rats
-
Silva, A, et al. Simultaneous BOLD and perfusion functional MRI during forepaw stimulation in rats. J. Cereb. Blood Flow Metab. 19 (1999), 871-879.
-
(1999)
J. Cereb. Blood Flow Metab.
, vol.19
, pp. 871-879
-
-
Silva, A.1
-
22
-
-
0032729595
-
Diffusion-weighted spin-echo fMRI at 9.4 T: microvasculuar/tissue contribution to BOLD signal change
-
Lee, S.-P., et al. Diffusion-weighted spin-echo fMRI at 9.4 T: microvasculuar/tissue contribution to BOLD signal change. Magn. Reson. Med. 42 (1999), 919-928.
-
(1999)
Magn. Reson. Med.
, vol.42
, pp. 919-928
-
-
Lee, S.-P.1
-
23
-
-
0036206456
-
Comparison of diffusion-weighted high-resolution CBF and spin-echo BOLD fMRI at 9.4 T
-
Lee, S.-P., Silva, A.C., Kim, S.-G., Comparison of diffusion-weighted high-resolution CBF and spin-echo BOLD fMRI at 9.4 T. Magn. Reson. Med. 47 (2002), 736-741.
-
(2002)
Magn. Reson. Med.
, vol.47
, pp. 736-741
-
-
Lee, S.-P.1
Silva, A.C.2
Kim, S.-G.3
-
24
-
-
0028854355
-
Multi-slice MRI of rat brain perfusion during amphetamine stimulation using arterial spin labeling
-
Silva, A.C., et al. Multi-slice MRI of rat brain perfusion during amphetamine stimulation using arterial spin labeling. Magn. Reson. Med. 33 (1995), 209-214.
-
(1995)
Magn. Reson. Med.
, vol.33
, pp. 209-214
-
-
Silva, A.C.1
-
25
-
-
33646376290
-
Spin diffusion measurements: spin echoes in the presence of a time-dependent field gradient
-
Stejskal, E.O., Tanner, J.E., Spin diffusion measurements: spin echoes in the presence of a time-dependent field gradient. J. Chem. Phys. 42 (1965), 288-292.
-
(1965)
J. Chem. Phys.
, vol.42
, pp. 288-292
-
-
Stejskal, E.O.1
Tanner, J.E.2
-
26
-
-
0021991039
-
What is the correct value for the brain–blood partition coefficient for water?
-
Herscovitch, P, Raichle, M.E., What is the correct value for the brain–blood partition coefficient for water?. J. Cereb. Blood Flow Metab. 5 (1985), 65-69.
-
(1985)
J. Cereb. Blood Flow Metab.
, vol.5
, pp. 65-69
-
-
Herscovitch, P.1
Raichle, M.E.2
-
27
-
-
0031947690
-
Quantitative measurements of cerebral blood flow in rats using the FAIR technique: correlation with previous iodoantipyrine autoradiographic studies
-
Tsekos, N.V., et al. Quantitative measurements of cerebral blood flow in rats using the FAIR technique: correlation with previous iodoantipyrine autoradiographic studies. Magn. Reson. Med. 39 (1998), 564-573.
-
(1998)
Magn. Reson. Med.
, vol.39
, pp. 564-573
-
-
Tsekos, N.V.1
-
28
-
-
0027288454
-
Processing strategies for time-course data sets in functional MRI of human brain
-
Bandettini, P.A., et al. Processing strategies for time-course data sets in functional MRI of human brain. Magn. Reson. Med. 30 (1993), 161-173.
-
(1993)
Magn. Reson. Med.
, vol.30
, pp. 161-173
-
-
Bandettini, P.A.1
-
29
-
-
0003698235
-
The rat brain in stereotaxic coordinates
-
Third ed. Academic Press San Diego
-
Paxinos, G, Watson, C, The rat brain in stereotaxic coordinates. Compact, Third ed., 1986, Academic Press, San Diego.
-
(1986)
Compact
-
-
Paxinos, G.1
Watson, C.2
-
30
-
-
0034100265
-
Functional MRI of calcium-dependent synaptic activity: cross-correlation with CBF and BOLD measurements
-
Duong, T.Q., et al. Functional MRI of calcium-dependent synaptic activity: cross-correlation with CBF and BOLD measurements. Magn. Reson. Med. 43 (2000), 383-392.
-
(2000)
Magn. Reson. Med.
, vol.43
, pp. 383-392
-
-
Duong, T.Q.1
-
31
-
-
0037069442
-
Laminar specificity of fMRI onset times during somatosensory stimulation in rat
-
Silva, A.C., Koretsky, A.P., Laminar specificity of fMRI onset times during somatosensory stimulation in rat. Proc. Natl. Acad. Sci. U. S. A. 99 (2002), 15182-15187.
-
(2002)
Proc. Natl. Acad. Sci. U. S. A.
, vol.99
, pp. 15182-15187
-
-
Silva, A.C.1
Koretsky, A.P.2
|