메뉴 건너뛰기




Volumn 17, Issue 5, 2007, Pages 902-906

In situ synthesis of nanostructured titania film on NiTi shape memory alloy by Fenton's oxidation method

Author keywords

corrosion; Fenton's oxidation; NiTi shape memory alloy(SMA); thin films

Indexed keywords

CORROSION RESISTANCE; MASS SPECTROMETRY; NANOSTRUCTURED MATERIALS; OXIDATION; SCANNING ELECTRON MICROSCOPY; SHAPE MEMORY EFFECT; SYNTHESIS (CHEMICAL); X RAY DIFFRACTION ANALYSIS;

EID: 36148929849     PISSN: 10036326     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1003-6326(07)60197-6     Document Type: Article
Times cited : (10)

References (18)
  • 4
    • 10044220962 scopus 로고    scopus 로고
    • Carbon plasma immersion ion implantation of nickel-titanium shape memory alloys [J]
    • POON R., WKYEUNG K., LIU X., CHU P., CHUNG C., LU W., CHEUNG K., and CHAN D. Carbon plasma immersion ion implantation of nickel-titanium shape memory alloys [J]. Biomaterials 26 (2005) 2265-2272
    • (2005) Biomaterials , vol.26 , pp. 2265-2272
    • POON, R.1    WKYEUNG, K.2    LIU, X.3    CHU, P.4    CHUNG, C.5    LU, W.6    CHEUNG, K.7    CHAN, D.8
  • 5
    • 0038462111 scopus 로고    scopus 로고
    • Calcium phosphate coating of nickel-titanium shape-memory alloys: Coating procedure and adherence of leukocytes and platelets [J]
    • CHOI J., BOGDANSKI D., KÖLLER M., ESENWEIN S., MÜLLER D., MUHR G., and EPPLE M. Calcium phosphate coating of nickel-titanium shape-memory alloys: Coating procedure and adherence of leukocytes and platelets [J]. Biomaterials 24 (2003) 3689-3696
    • (2003) Biomaterials , vol.24 , pp. 3689-3696
    • CHOI, J.1    BOGDANSKI, D.2    KÖLLER, M.3    ESENWEIN, S.4    MÜLLER, D.5    MUHR, G.6    EPPLE, M.7
  • 6
    • 0030128943 scopus 로고    scopus 로고
    • Spontaneous formation of bonelike apatite layer on chemically treated titanium metals [J]
    • KOKUBO T., MIYAJI F., KIM H., and NAKAMURA T. Spontaneous formation of bonelike apatite layer on chemically treated titanium metals [J]. J Am Ceram Soc 79 (1996) 1127-1129
    • (1996) J Am Ceram Soc , vol.79 , pp. 1127-1129
    • KOKUBO, T.1    MIYAJI, F.2    KIM, H.3    NAKAMURA, T.4
  • 8
    • 84956040351 scopus 로고
    • Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implants [J]
    • SHABALOVSKAYA S., and ANDEREGG J. Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implants [J]. J Vac Sci Technol A13 5 (1995) 2624-2632
    • (1995) J Vac Sci Technol , vol.A13 , Issue.5 , pp. 2624-2632
    • SHABALOVSKAYA, S.1    ANDEREGG, J.2
  • 9
    • 0012832732 scopus 로고    scopus 로고
    • Oxidation behavior of equiatomic TiNi alloy in high temperature air environment [J]
    • CHU C., WU S., and YEN Y. Oxidation behavior of equiatomic TiNi alloy in high temperature air environment [J]. Mater Sci Eng A 216 (1996) 193-200
    • (1996) Mater Sci Eng A , vol.216 , pp. 193-200
    • CHU, C.1    WU, S.2    YEN, Y.3
  • 11
    • 0035342607 scopus 로고    scopus 로고
    • In vivo evaluation of bone-bonding of titanium metal chemically treated with a hydrogen peroxide solution containing tantalum chloride [J]
    • KANEKO S., TSURU K., HAYAKAWA S., TAKEMOTO S., OHTSUKI C., OZAKI T., INOUE H., and OSAKA A. In vivo evaluation of bone-bonding of titanium metal chemically treated with a hydrogen peroxide solution containing tantalum chloride [J]. Biomaterials 22 (2001) 875-881
    • (2001) Biomaterials , vol.22 , pp. 875-881
    • KANEKO, S.1    TSURU, K.2    HAYAKAWA, S.3    TAKEMOTO, S.4    OHTSUKI, C.5    OZAKI, T.6    INOUE, H.7    OSAKA, A.8
  • 12
    • 25844477633 scopus 로고    scopus 로고
    • In situ formation of titania film on NiTi alloy treated with hydrogen peroxide solution at low temperature [J]
    • CHU C., ZHOU J., CHUNG C., PU Y., and LIN P. In situ formation of titania film on NiTi alloy treated with hydrogen peroxide solution at low temperature [J]. Trans Nonferrous Met Soc China 15 4 (2005) 834-838
    • (2005) Trans Nonferrous Met Soc China , vol.15 , Issue.4 , pp. 834-838
    • CHU, C.1    ZHOU, J.2    CHUNG, C.3    PU, Y.4    LIN, P.5
  • 14
    • 0037450951 scopus 로고    scopus 로고
    • A review of classic Fenton's peroxidation as an advanced oxidation technique [J]
    • NEYENS E., and BAEYENS J. A review of classic Fenton's peroxidation as an advanced oxidation technique [J]. Journal of Hazardous Materials B98 (2003) 33-50
    • (2003) Journal of Hazardous Materials , vol.B98 , pp. 33-50
    • NEYENS, E.1    BAEYENS, J.2
  • 15
    • 0348252206 scopus 로고    scopus 로고
    • Fenton's oxidation of MTBE with zero-valent iron [J]
    • BERGENDAHL J., and THIES T. Fenton's oxidation of MTBE with zero-valent iron [J]. Water Research 38 (2004) 327-334
    • (2004) Water Research , vol.38 , pp. 327-334
    • BERGENDAHL, J.1    THIES, T.2
  • 16
    • 0034980299 scopus 로고    scopus 로고
    • Corrosion behavior of titanium nitride coated Ni-Ti shape memory surgical alloy [J]
    • STAROSVETSKY D., and GOTMAN I. Corrosion behavior of titanium nitride coated Ni-Ti shape memory surgical alloy [J]. Biomaterials 22 13 (2001) 1853-1859
    • (2001) Biomaterials , vol.22 , Issue.13 , pp. 1853-1859
    • STAROSVETSKY, D.1    GOTMAN, I.2
  • 17
    • 0029336418 scopus 로고
    • Dependence of apatite formation on silica gel on its structure: Effect of heat treatment [J]
    • CHO S., NAKANISHI K., KOKUBO T., and SOGA N. Dependence of apatite formation on silica gel on its structure: Effect of heat treatment [J]. J Am Ceram Soc 78 (1995) 1769-1774
    • (1995) J Am Ceram Soc , vol.78 , pp. 1769-1774
    • CHO, S.1    NAKANISHI, K.2    KOKUBO, T.3    SOGA, N.4
  • 18
    • 23644434982 scopus 로고    scopus 로고
    • Improvements of anti-corrosion and mechanical properties of NiTi orthopedic materials by acetylene, nitrogen and oxygen plasma immersion ion implantation [J]
    • POON R., HO J., LIU X., CHUNG C., CHU P., YEUNG K., LU W., and CHEUNG K. Improvements of anti-corrosion and mechanical properties of NiTi orthopedic materials by acetylene, nitrogen and oxygen plasma immersion ion implantation [J]. Nuclear Instruments and Methods in Physics Research B237 (2005) 411-416
    • (2005) Nuclear Instruments and Methods in Physics Research , vol.B237 , pp. 411-416
    • POON, R.1    HO, J.2    LIU, X.3    CHUNG, C.4    CHU, P.5    YEUNG, K.6    LU, W.7    CHEUNG, K.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.