메뉴 건너뛰기




Volumn 40, Issue 1, 2008, Pages 19-25

In vivo visualization of early microcirculatory changes following ischemia/reperfusion injury in human kidney transplantation

Author keywords

Ischemia reperfusion injury; Microcirculation; Orthogonal polarization spectral imaging; Renal transplantation

Indexed keywords

C REACTIVE PROTEIN; CREATININE;

EID: 36049022415     PISSN: 0014312X     EISSN: None     Source Type: Journal    
DOI: 10.1159/000107683     Document Type: Article
Times cited : (38)

References (32)
  • 1
    • 0030816190 scopus 로고    scopus 로고
    • Cellular and molecular predictors of chronic renal dysfunction after initial ischemia/reperfusion injury of a single kidney
    • Azuma H, Nadeau K, Takada M, Mackenzie HS, Tilney NL: Cellular and molecular predictors of chronic renal dysfunction after initial ischemia/reperfusion injury of a single kidney. Transplantation 1997;64:190.
    • (1997) Transplantation , vol.64 , pp. 190
    • Azuma, H.1    Nadeau, K.2    Takada, M.3    Mackenzie, H.S.4    Tilney, N.L.5
  • 2
    • 18644373182 scopus 로고    scopus 로고
    • Direct visualization of cortical peritubular capillary of transplanted human kidney with reperfusion injury using a magnifying endoscopy
    • Hattori R, Ono Y, Kato M, Komatsu T, Matsukawa Y, Yamamoto T: Direct visualization of cortical peritubular capillary of transplanted human kidney with reperfusion injury using a magnifying endoscopy. Transplantation 2005;79:1190.
    • (2005) Transplantation , vol.79 , pp. 1190
    • Hattori, R.1    Ono, Y.2    Kato, M.3    Komatsu, T.4    Matsukawa, Y.5    Yamamoto, T.6
  • 3
    • 0026094369 scopus 로고
    • Red cell trapping and postischemic renal blood flow. Differences between the cortex, outer and inner medulla
    • Olof P, Hellberg O, Kallskog O, Wolgast M: Red cell trapping and postischemic renal blood flow. Differences between the cortex, outer and inner medulla. Kidney Int 1991;40:625.
    • (1991) Kidney Int , vol.40 , pp. 625
    • Olof, P.1    Hellberg, O.2    Kallskog, O.3    Wolgast, M.4
  • 4
    • 0036084058 scopus 로고    scopus 로고
    • Endothelial dysfunction in ischemic acute renal failure: Rescue by transplanted endothelial cells
    • Brodsky SV, Yamamoto T, Tada T, et al: Endothelial dysfunction in ischemic acute renal failure: rescue by transplanted endothelial cells. Am J Physiol Renal Physiol 2002;282:F1140.
    • (2002) Am J Physiol Renal Physiol , vol.282
    • Brodsky, S.V.1    Yamamoto, T.2    Tada, T.3
  • 5
    • 0015257383 scopus 로고
    • The role of cell swelling in ischemic renal damage and the protective effect of hyperonic solute
    • Flores J, DiBona D, Beck C, Leaf A: The role of cell swelling in ischemic renal damage and the protective effect of hyperonic solute. J Clin Invest 1972;51:118.
    • (1972) J Clin Invest , vol.51 , pp. 118
    • Flores, J.1    DiBona, D.2    Beck, C.3    Leaf, A.4
  • 6
    • 0015182818 scopus 로고
    • The no reflow phenomenon in renal ischemia
    • Summers WK, Jamison RL: The no reflow phenomenon in renal ischemia. Lab Invest 1971;25:635.
    • (1971) Lab Invest , vol.25 , pp. 635
    • Summers, W.K.1    Jamison, R.L.2
  • 7
    • 0024319490 scopus 로고
    • Renal ischemia and reperfusion impair endothelium-dependent vascular relaxation
    • Lieberthal W, Wolf EF, Rennke HG, Valeri CR, Levinsky NG: Renal ischemia and reperfusion impair endothelium-dependent vascular relaxation. Am J Physiol 1989;256(5 Pt 2):F894.
    • (1989) Am J Physiol , vol.256 , Issue.5 PART 2
    • Lieberthal, W.1    Wolf, E.F.2    Rennke, H.G.3    Valeri, C.R.4    Levinsky, N.G.5
  • 8
    • 0033946210 scopus 로고    scopus 로고
    • Quantitative blood velocity mapping in glomerular capillaries by in vivo observation with an intravital videomicroscope
    • Ogasawara Y, Takehara K, Yamamoto T, Hashimoto R, Nakamoto H, Kajiya F: Quantitative blood velocity mapping in glomerular capillaries by in vivo observation with an intravital videomicroscope. Methods Inf Med 2000;39:175.
    • (2000) Methods Inf Med , vol.39 , pp. 175
    • Ogasawara, Y.1    Takehara, K.2    Yamamoto, T.3    Hashimoto, R.4    Nakamoto, H.5    Kajiya, F.6
  • 9
    • 0034955116 scopus 로고    scopus 로고
    • In vivo visualization of angiotensin II and tubuloglomerular feedback-mediated renal vasoconstriction
    • Yamamoto T, Hayashi K, Matsuda H, et al: In vivo visualization of angiotensin II and tubuloglomerular feedback-mediated renal vasoconstriction. Kidney Int 2001;60:364.
    • (2001) Kidney Int , vol.60 , pp. 364
    • Yamamoto, T.1    Hayashi, K.2    Matsuda, H.3
  • 10
    • 0035173690 scopus 로고    scopus 로고
    • Direct in vivo visualization of renal microcirculation by intravital CCD videomicroscopy
    • Yamamoto T, Hayashi K, Tomura Y, Tanaka H, Kajiya F: Direct in vivo visualization of renal microcirculation by intravital CCD videomicroscopy. Exp Nephrol 2001;9:150.
    • (2001) Exp Nephrol , vol.9 , pp. 150
    • Yamamoto, T.1    Hayashi, K.2    Tomura, Y.3    Tanaka, H.4    Kajiya, F.5
  • 11
    • 0037469049 scopus 로고    scopus 로고
    • Assessment of renal graft function by perioperative monitoring of cortical microcirculation in kidney transplantation
    • Angelescu M, Kraus T, Wiesel M, Hergesell O, Haberkorn U, Klar E: Assessment of renal graft function by perioperative monitoring of cortical microcirculation in kidney transplantation. Transplantation 2003;75:1190.
    • (2003) Transplantation , vol.75 , pp. 1190
    • Angelescu, M.1    Kraus, T.2    Wiesel, M.3    Hergesell, O.4    Haberkorn, U.5    Klar, E.6
  • 12
    • 0036089273 scopus 로고    scopus 로고
    • Intravital videomicroscopy of peritubular capillaries in renal ischemia
    • Yamamoto T, Tada T, Brodsky SV, et al: Intravital videomicroscopy of peritubular capillaries in renal ischemia. Am J Physiol Renal Physiol 2002;282:F1150.
    • (2002) Am J Physiol Renal Physiol , vol.282
    • Yamamoto, T.1    Tada, T.2    Brodsky, S.V.3
  • 13
    • 0032828956 scopus 로고    scopus 로고
    • Orthogonal polarization spectral imaging: A new method for study of the microcirculation
    • Groner W, Winkelman JW, Harris AG, et al: Orthogonal polarization spectral imaging: a new method for study of the microcirculation. Nat Med 1999;5:1209.
    • (1999) Nat Med , vol.5 , pp. 1209
    • Groner, W.1    Winkelman, J.W.2    Harris, A.G.3
  • 14
    • 0004944442 scopus 로고    scopus 로고
    • Orthogonal polarization spectral imaging: State of the art
    • Nadeau RG, Groner W: Orthogonal polarization spectral imaging: state of the art. Progr Appl Microcirc 2000;24:9.
    • (2000) Progr Appl Microcirc , vol.24 , pp. 9
    • Nadeau, R.G.1    Groner, W.2
  • 15
    • 0002479770 scopus 로고
    • Measurement of diameter in microvascular studies
    • Baker CH, Nastuk WL eds, Orlando, Academic Press
    • Intaglietta M, Hammersen F: Measurement of diameter in microvascular studies; in Baker CH, Nastuk WL (eds): Microcirculatory Technology. Orlando, Academic Press, 1986, pp 137-148.
    • (1986) Microcirculatory Technology , pp. 137-148
    • Intaglietta, M.1    Hammersen, F.2
  • 17
    • 0344687379 scopus 로고    scopus 로고
    • Noninvasive in vivo analysis of the human hepatic microcirculation using orthogonal polarization spectral imaging
    • Puhl G, Schaser KD, Vollmar B, Menger MD, Settmacher U: Noninvasive in vivo analysis of the human hepatic microcirculation using orthogonal polarization spectral imaging. Transplantation 2003;75:756.
    • (2003) Transplantation , vol.75 , pp. 756
    • Puhl, G.1    Schaser, K.D.2    Vollmar, B.3    Menger, M.D.4    Settmacher, U.5
  • 18
    • 13144265740 scopus 로고    scopus 로고
    • In vivo imaging of human pancreatic microcirculation and pancreatic tissue injury in clinical pancreas transplantation
    • Schaser KD, Puhl G, Vollmar B, et al: In vivo imaging of human pancreatic microcirculation and pancreatic tissue injury in clinical pancreas transplantation. Am J Transplant 2005;5:341.
    • (2005) Am J Transplant , vol.5 , pp. 341
    • Schaser, K.D.1    Puhl, G.2    Vollmar, B.3
  • 19
    • 0031171594 scopus 로고    scopus 로고
    • Cap image - a new kind of computer-assisted video image analysis system for dynamic capillary microscopy (in German)
    • Klyscz T, Jünger M, Jung F, Zeintl H: Cap image - a new kind of computer-assisted video image analysis system for dynamic capillary microscopy (in German). Biomed Tech (Berl) 1997;42:168.
    • (1997) Biomed Tech (Berl) , vol.42 , pp. 168
    • Klyscz, T.1    Jünger, M.2    Jung, F.3    Zeintl, H.4
  • 21
    • 0001481918 scopus 로고
    • Exploratory repeated measures analysis for two or more groups
    • Looney SW, Stanley WB: Exploratory repeated measures analysis for two or more groups. Am Stat 1989;43:220.
    • (1989) Am Stat , vol.43 , pp. 220
    • Looney, S.W.1    Stanley, W.B.2
  • 22
    • 0032646965 scopus 로고    scopus 로고
    • New techniques for clinical assessment of the peripheral microcirculation
    • Carpentier PH: New techniques for clinical assessment of the peripheral microcirculation. Drugs 1999;59 Spec No:17.
    • (1999) Drugs , vol.59 , Issue.SPEC 17
    • Carpentier, P.H.1
  • 23
    • 36048995992 scopus 로고    scopus 로고
    • Advances of in vivo confocal scanning laser microscopy]
    • Tian KB, Zhou GY: [Advances of in vivo confocal scanning laser microscopy]. Shanghai Kou Qiang Yi Xue 2006;15:97.
    • (2006) Shanghai Kou Qiang Yi Xue , vol.15 , pp. 97
    • Tian, K.B.1    Zhou, G.Y.2
  • 24
    • 0034457604 scopus 로고    scopus 로고
    • Direct in vivo visualization of glomerular microcirculation by intravital pencil lensprobe CCD videomicroscopy
    • Yamamoto T, Hayashi K, Matsuda H, et al: Direct in vivo visualization of glomerular microcirculation by intravital pencil lensprobe CCD videomicroscopy. Clin Hemorheol Microcirc 2000;23:103.
    • (2000) Clin Hemorheol Microcirc , vol.23 , pp. 103
    • Yamamoto, T.1    Hayashi, K.2    Matsuda, H.3
  • 25
    • 0034352322 scopus 로고    scopus 로고
    • The Cytoscan Model E-II, a new reflectance microscope for intravital microscopy: Comparison with the standard fluorescence method
    • Harris AG, Sinitsina I, Messmer K: The Cytoscan Model E-II, a new reflectance microscope for intravital microscopy: comparison with the standard fluorescence method. J Vasc Res 2000;37:469.
    • (2000) J Vasc Res , vol.37 , pp. 469
    • Harris, A.G.1    Sinitsina, I.2    Messmer, K.3
  • 26
    • 0036087480 scopus 로고    scopus 로고
    • Validation of OPS imaging for microvascular measurements during isovolumic hemodilution and low hematocrits
    • Harris AG, Sinitsina I, Messmer K: Validation of OPS imaging for microvascular measurements during isovolumic hemodilution and low hematocrits. Am J Physiol Heart Circ Physiol 2002;282:H1502.
    • (2002) Am J Physiol Heart Circ Physiol , vol.282
    • Harris, A.G.1    Sinitsina, I.2    Messmer, K.3
  • 27
    • 0031740823 scopus 로고    scopus 로고
    • Intravital fluorescence microscopy for the study of leukocyte interaction with platelets and endothelial cells
    • Lehr HA, Vollmar B, Vajkoczy P, Menger MD: Intravital fluorescence microscopy for the study of leukocyte interaction with platelets and endothelial cells. Methods Enzymol 1999;300:462.
    • (1999) Methods Enzymol , vol.300 , pp. 462
    • Lehr, H.A.1    Vollmar, B.2    Vajkoczy, P.3    Menger, M.D.4
  • 29
    • 23844462182 scopus 로고    scopus 로고
    • Molecular mechanics and dynamics of leukocyte recruitment during inflammation
    • Simon SI, Green CE: Molecular mechanics and dynamics of leukocyte recruitment during inflammation. Annu Rev Biomed Eng 2005;7:151.
    • (2005) Annu Rev Biomed Eng , vol.7 , pp. 151
    • Simon, S.I.1    Green, C.E.2
  • 30
    • 4444354773 scopus 로고    scopus 로고
    • The delay of rearterialization after initial portal reperfusion in living donor liver transplantation significantly determines the development of microvascular graft dysfunction
    • Puhl G, Schaser KD, Pust D, et al: The delay of rearterialization after initial portal reperfusion in living donor liver transplantation significantly determines the development of microvascular graft dysfunction. J Hepatol 2004;41:299.
    • (2004) J Hepatol , vol.41 , pp. 299
    • Puhl, G.1    Schaser, K.D.2    Pust, D.3
  • 31
    • 0027053338 scopus 로고
    • Microvascular ischemia-reperfusion injury in striated muscle: Significance of 'no reflow'. Am
    • Menger MD, Steiner D, Messmer K: Microvascular ischemia-reperfusion injury in striated muscle: significance of 'no reflow'. Am J Physiol 1992;263(6 Pt 2):H1892.
    • (1992) J Physiol , vol.263 , Issue.6 PART 2
    • Menger, M.D.1    Steiner, D.2    Messmer, K.3
  • 32
    • 0015538539 scopus 로고
    • High-frequency microcinematographic measurements on peritubular blood flow under control conditions and after temporary ischemia of rat kidneys
    • Steinhausen M, Eisenbach GM, Bottcher W: High-frequency microcinematographic measurements on peritubular blood flow under control conditions and after temporary ischemia of rat kidneys. Pflugers Arch 1973;339:273.
    • (1973) Pflugers Arch , vol.339 , pp. 273
    • Steinhausen, M.1    Eisenbach, G.M.2    Bottcher, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.